Overview
HVG-150-54AB is the 54V output model of this series: rated current 2.78A, rated power 150.12W, typical efficiency 91.5%. Type AB: Io and Vo adjustable through built-in potentiometer & 3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance) (IP65).
HVG-150 series is a 150W AC/DC LED power supply featuring the dual mode constant voltage and constant current output. HVG-150 operates from 180~528 VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 91.5%, with the fanless design, the series is able to operate from -40℃ through as high as +85℃ case temperature under free air convection. The design of metal housing and IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HVG-150 is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Wide input range 180 ~ 528VAC
- Constant Voltage + Constant Current mode output
- Metal housing with ClassⅠdesign
- Built-in active PFC function
- IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off)
- Typical lifet ime>50000 hours
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 54V
- CONSTANT CURRENT REGIONNote.4
- 29.7~54V
- RATED CURRENT
- 2.78A
- RATED POWER
- 150.12W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- Adjustable for AB-Type only (via the built-in potentiometer) 49 ~ 58V
- CURRENT ADJ. RANGE
- Adjustable for AB-Type only (via the built-in potentiometer) 1.53 ~ 2.78A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 500ms, 80ms /230VAC, 347VAC, 480VAC
- HOLD UP TIME (Typ.)
- 18ms/347VAC, 480VAC
INPUT
- VOLTAGE RANGENote.5
- 180 ~ 528VAC 254VDC ~ 747VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/230VAC, PF≧0.97/277VAC, PF≧0.95/347VAC, PF≧0.93/480VAC @full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20%(@ load≧50%/230VAC, 277VAC, 347VAC [@ load≧60% only for 12V model]; @ load≧75%/480VAC) (Please refer to “TOTAL HARMONIC DISTORTION (THD) ” section)
- EFFICIENCY (Typ.)
- 91.5%
- INRUSH CURRENT (Typ.)
- COLD START 35A(twidth=790μs measured at 50% Ipeak) at 480VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 4 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 480VAC
- LEAKAGE CURRENT
- <0.75mA / 480VAC
PROTECTION
- OVER CURRENT
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 59 ~ 65V Shut down o/p voltage with auto-recovery or re-power on to recovery
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- Tcase=-40 ~ +85℃(-40 ~ +75℃ for 12V model, -40 ~ +80℃ for 15V model)(Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase=+85℃(+75℃ for 12V model, +80℃ for 15V model)
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 60℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.7
- UL8750(type”HL”), CSA C22.2 No. 250.0-08, EAC TP TC 004, IP65 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to EN55015, EN61000-3-2 Class C (@ load≧55% load,@ load≧60% only for 12V model ) ; EN61000-3-3, FCC Part 15 Subpart,EAC TP TC 020
- EMC IMMUNITY
- Compliance to EN61000-4-2,3,4,5,6,8,11, EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020
OTHERS
- MTBF
- 1796.5K hrs min. Telcordia SR-332(Bellcore) ; 158.6K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 245*68*38.8mm (L*W*H)
- PACKING
- 1.24Kg; 12pcs/15.9Kg/0.78CUFT
Certifications & ratings
- Type
- HL
MODEL ENCODING
- A
- Io and Vo adjustable through built-in potentiometer; IP65
- B
- 3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance); IP67
- AB (this model)
- Io and Vo adjustable through built-in potentiometer & 3 in 1 dimming function (0~10Vdc, 10V PWM signal and resistance); IP65
- D
- Timer dimming function, contact MEAN WELL for details(safety pending); IP67
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 347VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 12. For A/AB type need to consider build in using to comply with Type HL application.
- 13. This product is intended for North America lighting equipment application. Please contact your MEAN WELL sales if you have other using.
Technical drawings
Typical applications
- LED street lighting
- LED high-bay lighting
- Parking space lighting
- LED fishing lamp
- LED greenhouse lighting
- Type "HL" for use in ClassⅠ, Division 2 hazardous (Classified) location.
Downloads
FAQ
Can I use the HVG-150-54AB for long 54V LED strip runs?
Yes, if the strip is designed for 54V and the full run stays within 150.12W. This model supplies up to 2.78A at 54V, which supports higher-voltage lighting systems with lower current than comparable lower-voltage drivers. Check your strip rated power per meter before calculating the maximum length.
Is this driver suitable for 54V signage lighting or illuminated display frames?
It can be used for 54V signage and display lighting loads that fit within its 150.12W rating. The constant-current operating range is 29.7~54V, so the connected LED load needs to be compatible with that range. Its IP65 water-resistant housing makes it better suited to protected outdoor or indoor commercial installations.
Can the HVG-150-54AB be used for architectural accent lighting?
It is suitable for 54V architectural LED lighting systems that need up to 150.12W and up to 2.78A output. The aluminium casing and -40°C to +85°C operating temperature range make it usable in demanding ambient conditions. Use it where an IP65 water-resistant enclosure is appropriate rather than where full IP67 waterproofing is required.
What LED strip length can I estimate from this 54V 150.12W driver?
Estimate strip length by dividing 150.12W by the strip's watts per meter. For example, a 54V strip rated at 20W/m would estimate to about 7.51m because 150.12 / 20 = 7.506. Check your strip rated power per meter and keep the total load within 150.12W and 2.78A.
Is the HVG-150-54AB suitable for wet outdoor areas?
It is rated IP65, so it is water-resistant and suited to outdoor locations where the driver is not subjected to full submersion-level exposure. That makes it appropriate for damp or sheltered exterior environments, but less sealed than an IP67 version. Its operating range of -40°C to +85°C supports hot and cold conditions.
What are the sibling options around the HVG-150-54AB?
Within the same 54V family, HVG-150-54A, HVG-150-54AB, and HVG-150-54B are all rated 150.12W, 54V, and 2.78A. The lower-power sibling is HVG-150-12 at 120W. If you need a smaller or larger 54V option, the series also includes 95.58W 54V 1.77A models in the 100 range and 243W 54V 4.5A or 324W 54V 6A models in the 240 and 320 ranges.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.