💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well LOP-600-24 600W 5"×3" Low Profile Open Frame Power Supply 24V 16.7A

conventional 400W600W if using fanhigh frequency up to 95%
SKU LOP-600-24
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

LOP-600-24 is the 24V output model of this series: typical efficiency 94%.

The LOP-600 is a 600W highly reliable, energy-efficient, low-profile open frame type power supply. With a high power density of 30.3W/in³ within the standard size of 5" × 3", it features a universal input voltage range of 80~264VAC, making it suitable for global applications. The series offers a comprehensive selection of standard voltages, including 12V/15V/18V/24V/27V/36V/48V/54V, and comes in a complete range of models. The main features of the LOP-600 include: low standby power (<0.5W), high efficiency (up to 95%), capable of providing 400W under natural air cooling and 600W with an additional fan. It has a 150% @ 3 seconds overload capacity, a wide operating temperature range of -40 to +80℃, compliance with OVC III, suitable for Class I (with FG) or Class II (without FG) systems. The product has obtained multiple safety certifications, including 62368-1/60601-1/61558-1/60335-1, and is designed to meet 2xMOPP and extremely low touch leakage current <70 μ A, making it suitable for BF class medical devices. With high product safety and excellent EMC performance, it is versatile and applicable in various fields such as ITE, medical, industrial control, home automation and more. It is a cost-effective slim open frame type power supply.

Features

  • MEAN WELL Patent Number: ZL 202223277512.1
  • 5"×3" compact size with low profile (12V: 35mm ,15~54V: 33.5mm )
  • 80~264Vac input with PFC, No load power consumption<0.5W
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)
  • 150%peak load @ 3s
  • 400W convection, 600W with FAN 23CFM forced-cooled
  • Suitable for Class Ⅰor Class Ⅱ installations
  • Overvoltage category Ⅲ (OVC Ⅲ)
  • -40 ~ +80℃ wide range operation temperature
  • High efficiency up to 95%
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Extremely low leakage current, 2 x MOPP, suitable for BF medical applications
  • Operating altitude up to 5000 meters
  • Built-in 12V/0.5A for external FAN
  • Built-in Remote sense
  • 3 years warranty

Specifications

LOP-600-24Specifications from the official datasheet (2026-06-17 edition)

OUTPUT

DC VOLTAGE
24V
CURRENT Peak(3sec.)
37.5A
CURRENT 23CFM
25A
CURRENT Convection
16.7A
RATED POWER Peak(3sec.)
900W
RATED POWER 23CFM
600W
RATED POWER Convection
400.8W
RIPPLE & NOISE (max.)Note.2
200mVp-p
VOLTAGE ADJ. RANGE (MAIN OUTPUT)
22.8~25.2V
VOLTAGE TOLERANCENote.3
±2.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±1.0%
SETUP, RISE TIME
1000ms, 50ms/230Vac 1500ms, 50ms/115Vac at full load
HOLD UP TIME (Typ.)
12ms@400W load , 8ms@600W load

INPUT

VOLTAGE RANGENote.4
80 ~ 264Vac 113 ~ 370Vdc
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF>0.95/230Vac PF>0.98/115Vac at full load
EFFICIENCY (Typ.)
94%
AC CURRENT (Typ.)
6.4A/115Vac 3.2A/230Vac
INRUSH CURRENT (Typ.)
COLD START 40A/115Vac 80A/230Vac
LEAKAGE CURRENT
ClassⅠ: Earth leakage current < 500 μA (rms) @ 264V ac , touch current < 70μA (rms) @ 264V ac ClassⅡ: Touch current < 100 μA (rms) @ 264V ac

PROTECTION

OVERLOAD
105 ~ 150% rated output power, Protection type : Hiccup after 3 sec, recovers automatically after fault condition is removed
OVER VOLTAGE
26.4 ~ 31.2V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Protection type : Shut down o/p voltage, recovers automatically after temperature goes down or re-power on to recover

FUNCTION

EXTERNAL FAN SUPPLY
12V@0.5A for driving a fan (23CFM) / 12V@0.2A for without fan; Tolerance -15% ~+15% at main output 20% rated current
REMOTE SENSE
The remote sensing compensates voltage drop on the load wiring up to 0.5V
POWER GOOD / POWER FAIL (optional)
500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value; TTL(0 ~ 1V), TTH(2 ~ 5V)

ENVIRONMENT

WORKING TEMP.
-40 ~ +80℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDSNote.5
CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC60601-1; TUV BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN60601-1(3.2 Version); UL UL62368-1, ANSI / AAMI ES60601-1(3.2 Version) ; CCC GB4943.1 ; RCM AS/NZS 61558-1/-2-16; EAC TPTC 004 approved.
ISOLATION RESISTANCE
Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
OVER VOLTAGE CATEGORY
IEC/EN 61558-1/-2-16(OVC Ⅲ, altitude up to 2000M ) IEC/EN/UL 62368-1 (OVC Ⅱ, altitude up to 5000M ) IEC/EN 60335-1 (OVC Ⅱ, altitude up to 5000M ) IEC/EN 60601-1 (OVC Ⅱ, altitude up to 4000M )
PROTECTIVE EXTRA-LOW VOLTAGE
IEC/EN61558-2-16 (SELV, 12~48V ) IEC/EN/UL 62368-1 (SELV / ES1, 12~48V )
WITHSTAND VOLTAGE
I/P-O/P:4KVac I/P-FG:2KVac O/P-FG:1.5KVac
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
Conducted & RadiatedBS EN/EN55032(CISPR32) BS EN/EN55011(CISPR11)ClassⅠ: Class B , Class Ⅱ: Class A
Conducted & RadiatedBS EN/EN55014(CISPR32)ClassⅠ: Class B
Harmonic CurrentBS EN/EN61000-3-2Class A
Voltage FlickerBS EN/EN61000-3-3
EMC IMMUNITY

BS EN/EN55035,BS EN/ EN61000-6-2

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 4, 15KV air; Level 4, 8KV contact
Radiated SusceptibilityBS EN/EN61000-4-3Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT/BurestBS EN/EN61000-4-4Level 3, 2KV
SurgeBS EN/EN61000-4-5Level 4, 4KV/Line-FG; 2KV/Line-Line
ConductedBS EN/EN61000-4-6Level 3, 10V
Magnetic FieldBS EN/EN61000-4-8Level 4, 30A/m
Voltage Dips and interruptionsBS EN/EN61000-4-11>95% dip 0.5 periods, 100% dip 1 periods, 30% dip 25 periods, >95% interruptions 250 periods

OTHERS

MTBF
1963.2K hrs min. Telcordia SR-332 (Bellcore) ; 310.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
12V: 127*76.2*35mm (L*W*H) , 15~54V: 127*76.2*33.5mm (L*W*H)
PACKING
0.48Kg; 24pcs/13.7Kg/1.10CUFT
Test conditions and notes5
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)

Technical drawings

LOP-600-24 LOP-600 series
LOP-600 series
LOP-600-24 Derating Curve
Derating Curve
LOP-600-24 Output Derating VS Input Voltage
Output Derating VS Input Voltage
LOP-600-24 LOP-600 series
LOP-600 series

Typical applications

  • Industrial automation machinery/ control system
  • Security system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Network equipment
  • Telecom devices
  • Power sourcing equipment of PoE
  • Home automation
  • Medical devices

Downloads

FAQ

What are the key electrical specs of the Mean Well LOP-600-24?

The Mean Well LOP-600-24 is a 600W open frame AC-DC power supply with a 24V output, rated 25A with 23CFM forced-air cooling or 16.7A under convection. It accepts 80 to 264VAC input, includes active PFC, and has a typical efficiency of 94%.

Is the LOP-600-24 suitable for space-constrained equipment?

Yes. This model uses a compact 5 x 3 inch footprint and a low-profile design, with a height of 33.5mm for the 24V version. That makes it a strong fit for equipment where board space and vertical clearance are limited.

Can the LOP-600-24 operate in harsh temperature environments?

This power supply is rated for operation from -40°C to +80°C, subject to the manufacturer's derating guidance. That wide operating range makes it suitable for demanding industrial and enclosed equipment environments.

Does the LOP-600-24 support medical or safety-sensitive applications?

The LOP-600-24 carries medical IEC/EN 60601-1 and ANSI/AAMI ES60601-1 approvals, and its primary-to-secondary isolation is specified as 2 x MOPP. Its safety approvals also cover ITE, household, and industrial use categories.

How does the LOP-600-24 handle peak loads and cooling conditions?

This model is rated for 400W under convection cooling and up to 600W with 23CFM forced-air cooling. It also supports 150% peak load for 3 seconds, which can help with short-duration load surges in demanding equipment.

What protection features are built into the Mean Well LOP-600-24?

The LOP-600-24 includes overload, overvoltage, and overtemperature protection. The overload protection operates in hiccup mode after 3 seconds and recovers automatically after the fault is removed, while overvoltage and overtemperature use shutdown-based protection behavior.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":14620235923822, "variants" :[{ "context":"default", "variant_id": 51639722017134, "sku":"LOP-600-24", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well LOP-600-24 600W 5"×3" Low Profile Open Frame Power Supply 24V 16.7A
Mean Well

Mean Well LOP-600-24 600W 5"×3" Low Profile Open Frame Power Supply 24V 16.7A

LOP-600-24 is the 24V output model of this series: typical efficiency 94%.

The LOP-600 is a 600W highly reliable, energy-efficient, low-profile open frame type power supply. With a high power density of 30.3W/in³ within the standard size of 5" × 3", it features a universal input voltage range of 80~264VAC, making it suitable for global applications. The series offers a comprehensive selection of standard voltages, including 12V/15V/18V/24V/27V/36V/48V/54V, and comes in a complete range of models. The main features of the LOP-600 include: low standby power (<0.5W), high efficiency (up to 95%), capable of providing 400W under natural air cooling and 600W with an additional fan. It has a 150% @ 3 seconds overload capacity, a wide operating temperature range of -40 to +80℃, compliance with OVC III, suitable for Class I (with FG) or Class II (without FG) systems. The product has obtained multiple safety certifications, including 62368-1/60601-1/61558-1/60335-1, and is designed to meet 2xMOPP and extremely low touch leakage current <70 μ A, making it suitable for BF class medical devices. With high product safety and excellent EMC performance, it is versatile and applicable in various fields such as ITE, medical, industrial control, home automation and more. It is a cost-effective slim open frame type power supply.

Features

  • MEAN WELL Patent Number: ZL 202223277512.1
  • 5"×3" compact size with low profile (12V: 35mm ,15~54V: 33.5mm )
  • 80~264Vac input with PFC, No load power consumption<0.5W
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16)
  • 150%peak load @ 3s
  • 400W convection, 600W with FAN 23CFM forced-cooled
  • Suitable for Class Ⅰor Class Ⅱ installations
  • Overvoltage category Ⅲ (OVC Ⅲ)
  • -40 ~ +80℃ wide range operation temperature
  • High efficiency up to 95%
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Extremely low leakage current, 2 x MOPP, suitable for BF medical applications
  • Operating altitude up to 5000 meters
  • Built-in 12V/0.5A for external FAN
  • Built-in Remote sense
  • 3 years warranty

Typical applications

  • Industrial automation machinery/ control system
  • Security system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Network equipment
  • Telecom devices
  • Power sourcing equipment of PoE
  • Home automation
  • Medical devices
View product