Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NDR-480-48 is the 48V output model of this series: rated current 10A, rated power 480W, typical efficiency 92.5%.
NDR-480 is one economical slim 480W Din rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 85.5mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to BS EN/EN61000-3-2, the norm the European Union regulates for harmonic current. NDR-480 is designed with metal housing that enhances the unit's power dissipation. With working efficiency up to 92.5%, the entire series can operate at the ambient temperature between -20℃ and 70℃ under air convection. It is equipped with constant current mode for over-load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TÜV BS EN/EN62368-1, and etc.) make NDR-480 a very competitive power supply solution for industrial applications.
Features
- Universal AC input / Full range
- Built-in active PFC function
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 10A
- CURRENT RANGE
- 0 ~ 10A
- RATED POWER
- 480W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 48 ~ 55V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 1500ms, 100ms/230VAC 3000ms, 100ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.94/230VAC at full load
- EFFICIENCY (Typ.)
- 92.5%
- AC CURRENT (Typ.)
- 4.8A/115VAC 2.4A/230VAC
- INRUSH CURRENT (Typ.)
- 20A/115VAC 35A/230VAC
- LEAKAGE CURRENT
- <2mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 130% rated output power Protection type : Constant current limiting, unit will shut down after 3 sec., re-power on to recover
- OVER VOLTAGE
- 56 ~ 65V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃ )
- VIBRATION
- Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- Ul508, TUV BS EN/EN62368-1, EAC TP TC 004 , BSMI CNS15598-1 , IS13252(Part1)/IEC60950-1(except for 48V) approved; (meet BS EN/EN60204-1)
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32),BS EN/EN61204-3 Class B,BS EN/EN61000-3-2,-3,EAC TP TC 020,CNS15936 Class B
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN61204-3, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1041.6K hrs min. Telcordia SR-332 (Bellcore) ; 146.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 85.5*125.2*128.5mm (W*H*D)
- PACKING
- 1.5Kg; 8pcs/13Kg/0.9CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
- 5. Derating may be needed under low input voltage. Please check the derating curve for more details.
- 6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Industrial control system
- Factory automation
- Electro-mechanical apparatus
Downloads
Certificates4
Test reports1
FAQ
Can I use the NDR-480-48 for a high-power 48V industrial automation cabinet?
Yes, this model delivers 48VDC at up to 10A with a total output rating of 480W. That makes it suitable for higher-power 48V industrial automation cabinets where smaller 120W or 240W supplies would not provide enough output capacity.
Is the NDR-480-48 suitable for 48V control panels with multiple subsystems?
It is suitable for 48V control panels with multiple subsystems when the total demand remains within 10A and 480W. The DIN rail construction and 85.5 × 125.2 × 128.5 mm housing support centralized 48VDC power inside larger panel builds.
Can this 48V DIN rail power supply be used in telecom or building systems that need more current?
Yes, it can fit telecom or building system enclosures that use 48VDC and need more output current, up to 10A. The 90-264VAC input range also supports use in cabinet designs intended for varied AC input sources.
Is the NDR-480-48 designed for enclosed cabinet use?
Yes, this unit is intended for DIN rail mounting inside a control cabinet or electrical enclosure. The listed operating range is -20°C to +70°C, and while the metal case supports industrial panel use, no ingress rating is provided in these specs for exposed installation conditions.
How does the NDR-480-48 compare with the other Mean Well NDR models?
The sibling list includes NDR-75-12 at 75.6W 12V 6.3A, NDR-75-24 at 76.8W 24V 3.2A, NDR-75-48 at 76.8W 48V 1.6A, NDR-120-12 at 120W 12V 10A, NDR-120-24 at 120W 24V 5A, NDR-120-48 at 120W 48V 2.5A, NDR-240-24 at 240W 24V 10A, NDR-240-48 at 240W 48V 5A, and NDR-480-24 at 480W 24V 20A. The NDR-480-48 is the 48V 480W model rated at 10A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NDR-480 Models
1 other model| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well NDR-480-24 Single Output Industrial Power Supply 480W 24V 20A - DIN Rail | 480W | 24V | 20A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.