Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NID35-15 is the 15V output model of this series: rated power 36W, typical efficiency 96%.
Features
- Economical open frame design
- Wide input range
- High efficiency up to 96%
- Remote ON / OFF control
- Compact size 2.0"×0.512"× 0.433"(SIP package)
- Protections: Short circuit / Overload / Over voltage
- -30~+85℃ wide working temperature
- Cooling by free air convection
- Comply to BS EN/EN55032 ClassA without additional components
- Trimming output (optional)
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- CURRENT RANGE
- 0 ~ 2.4A
- RATED POWER
- 36W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±0.5%
- VOLTAGE TOLERANCE
- ±2.0%
- SWITCHING FREQUENCY (Typ.)
- 200KHz
- EXTERNAL CAPACITANCE LOAD (max.)
- 47uf/50V low ESR
INPUT
- VOLTAGE RANGE
- 20 ~ 53VDC
- NORMAL VOLTAGE
- 24VDC (or 48VDC)
- EFFICIENCY (Typ.) 24Vin
- 96%
- EFFICIENCY (Typ.) 48Vin
- 94%
- DC CURRENT Full load
- 1620mA/24VDC
- DC CURRENT No load
- 30mA
PROTECTION
- PROTECTION
- Fuse recommended (3A)
- OVERLOAD (Typ.)
- 120 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 17.5~ 21V Protection type : Shut off o/p voltage, clamp by TVS diode
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
FUNCTION
- REMOTE CONTROL
- Power on : 1.2VDC < R.C ~ com < 12VDC or open circuit ; power off : R.C ~ com < 0.4VDC or short circuit (PIN5,6 & PIN11)
ENVIRONMENT
- SAFETY STANDARDS
- EAC TP TC 004 approved
- WORKING TEMP.
- -30 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 85% RH non-condensing
- STORAGE TEMP.
- -30 ~ +105℃
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 55℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARD
- BS EN/EN62368-1(LVD)
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A without external components,Class B with external components Radiated BS EN/EN55032 Class A without external components,Class B with external components - EMC IMMUNITY
-
BS EN/EN55035
Parameter Standard Test Level Radiated BS EN/EN61000-4-3 Level 2, 3V/m; criteria A EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV; criteria A Surge BS EN/EN61000-4-5 Level 2, 1KV/Line-Line,criteria A Conducted BS EN/EN61000-4-6 Level 2, 3V; criteria A
OTHERS
- MTBF
- 12321.5K hrs min. Telcordia SR-332 (Bellcore) ; 757.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*13*11mm or 2.0"*0.512"*0.433" inch (L*W*H)
- WEIGHT
- 9g;440psc/4.96Kg/0.94CUFT
Test conditions and notes4
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH Ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
Technical drawings
Downloads
Certificates3
Test reports1
FAQ
Can I use the NID35-15 for 15V industrial control or embedded electronics?
Yes, this model provides constant-voltage 15V output rated at 36W and 2.4A. It is appropriate for 15V electronic loads in industrial or embedded systems when the total demand stays within 36W and 2.4A. It is not intended for loads that require a different output voltage.
Is the NID35-15 suitable for 15V instrumentation or automation interface boards?
It can be a fit where the equipment requires a regulated 15V rail and the load stays within 2.4A. With a 36W rating, it suits smaller 15V instrumentation, interface, or control sections rather than high-power assemblies. The converter uses constant-voltage output, which matches standard 15V electronics.
Can this converter power a compact 15V subsystem from a variable input source?
It is designed for a 20 to 53V input range and outputs 15V constant voltage. That makes it relevant for compact 15V subsystems fed from an input source that moves within that range. Output capacity is limited to 36W and 2.4A.
How does the NID35-15 compare with the other NID35 models?
The NID35-15 delivers 36W at 15V with 2.4A output. Its siblings are NID35-12 at 34.8W, 12V, 2.9A; NID35-24 at 36W, 24V, 1.5A; and NID35-5 at 17.5W, 5V, 3.5A. Across the family, the output voltage changes first, and current and wattage adjust with it.
Is the NID35-15 meant for outdoor use or temperature-challenging indoor panels?
The specified operating temperature range is -30°C to +85°C, so it is rated for demanding indoor temperature conditions. The provided specs do not list an IP rating or enclosure class. Based on the listed information, temperature capability is defined but outdoor exposure protection is not.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NID35 Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well NID35-5 DC-DC Converter - 17.5W - 10.5~53V in 5V out 3.5A | 17.5W | 5V | 3.5A | IP20 | View |
| Mean Well NID35-24 DC-DC Converter - 36W - 30~53V in 24V out 1.5A | 36W | 24V | 1.5A | IP20 | View |
| Mean Well NID35-12 DC-DC Converter - 34.8W - 20~53V in 12V out 2.9A | 34.8W | 12V | 2.9A | IP20 | View |