Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PSC-60A-C is the model of this series: rated power 59.34W, typical efficiency 84%.
Features
- Universal AC input / Full range
- Models with L-Bracket and cover available (PSC-60x-C, x=A,B)
- Protections: Short circuit / Overload / Over voltage
- Battery low protection / Battery reverse polarity protection by fuse
- Alarm signal for AC OK and Battery reverse low
- Cooling by free air convection
- 100% full load burn-in test
- 2 years warranty
Specifications
OUTPUT
- OUTPUT NUMBER
- CH1, CH2
- DC VOLTAGE (CH1)
- 13.8V
- DC VOLTAGE (CH2)
- 13.8V
- RATED CURRENT (CH1)
- 2.8A
- RATED CURRENT (CH2)
- 1.5A
- CURRENT RANGE (CH1)
- 0 ~ 4.3A
- CURRENT RANGE (CH2)
- --------
- RATED POWER
- 59.34W
- RIPPLE & NOISE (max.) (CH1)Note.2
- 120mVp-p
- RIPPLE & NOISE (max.) (CH2)Note.2
- --------
- VOLTAGE ADJ. RANGE
- CH1: 12 ~ 15V
- VOLTAGE TOLERANCE (CH1)Note.3
- ±1.0%
- VOLTAGE TOLERANCE (CH2)Note.3
- --------
- LINE REGULATION (CH1)
- ±0.5%
- LINE REGULATION (CH2)
- --------
- LOAD REGULATION (CH1)
- ±0.5%
- LOAD REGULATION (CH2)
- --------
- SETUP, RISE TIMENote.4
- 800ms, 50ms/230VAC 1600ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 10ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT (Typ.)
- 1.6A/115VAC 1A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 30A/115VAC 60A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- CH1:14.49 ~ 18.63V Protection type : Hiccup mode, recovers automatically after fault condition is removed
- BATTERY CUT OFF
- 10.5±0.5V
FUNCTION
- AC OK
- TTL open collector output, ON : AC OK ; OFF : AC Fail ; Ice : max. 30mA@ 50VDC
- BATTERY LOW
- TTL open collector output, ON : Battery Low ; OFF : Battery OK ; Ice : max. 30mA@ 50VDC
- Battery low voltage
- < 11V
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~50℃) on CH1 output
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCENote 7
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 3681.4K hrs min. Telcordia SR-332 (Bellcore) ; 589.7K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- PCB:101.6*50.8*29mm (L*W*H) ; Enclosed type:103.4*62*37mm (L*W*H)
- PACKING
- PCB:0.13Kg; 96pcs/13.5Kg/1.39CUFT ; Enclosed type:0.29Kg; 45pcs/14Kg/0.63CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 5. Heat sink HS1,HS2 can not be shorted.
- 6. Heat sink HS1 must have safety isolation distance with system case.
- 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Certificates7
Test reports1
Catalogues1
FAQ
Can I use the PSC-60A-C for a 12V battery-backed PLC or HMI cabinet?
The PSC-60A-C provides 13.8V constant-voltage output at up to 2.8A, with 59.34W total output power. That makes it a fit for lower-power 12V-class PLC, HMI, or control-panel backup applications that stay inside those electrical limits.
Is the PSC-60A-C appropriate for embedded automation or monitoring equipment that needs backup power?
It can be used where the equipment expects a 13.8V source and the total draw does not exceed 2.8A or 59.34W. The built-in battery charger and backup control function is relevant for systems that need charging and backup behavior from the same unit.
Can the PSC-60A-C support a compact 12V security or communications enclosure?
Electrically, it is the 13.8V, 2.8A, 59.34W version in the PSC range, so it suits smaller 12V-class backup applications within that output envelope. Mechanically, this -C version measures 103.4 × 62.0 × 37.0 mm and weighs 0.29 kg, which matters when enclosure space is limited.
Can the PSC-60A-C be used outdoors or in unconditioned spaces?
Its operating range is -20°C to +70°C, so temperature capability is broader than basic room-only equipment. However, no IP rating is provided in the listed specs, so outdoor exposure should not be assumed from the available data.
What are the main PSC series choices around the PSC-60A-C?
For 13.8V outputs, the listed options are PSC-35A and PSC-35A-C at 35.88W and 1.7A, PSC-60A and PSC-60A-C at 59.34W and 2.8A, PSC-100A and PSC-100A-C at 100.05W and 4.75A, PSC-100A-CWE at 100.5W and 4.75A, and PSC-160A and PSC-160A-C at 160W and 7.6A. For 27.6V outputs, the family includes PSC-35B and PSC-35B-C at 35.88W and 0.85A, PSC-60B and PSC-60B-C at 59.34W and 1.4A, PSC-100B and PSC-100B-C at 100.74W and 2.4A, and PSC-160B and PSC-160B-C at 160W and 3.8A; PSC-60-CWE, PSC-60A-CWE, and PSC-100-CWE are listed separately without full specs in this dataset.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.