Mean Well RSDW20UW-05 Ultra-wide input DC/DC LED Driver 20W 5V - Heavy Duty 4A

compliance with EN50155 and EN45545 railway standards2:1 or 4:1 wide input rangeisolation 4000VDC1U low profilehalf encapsulated
SKU RSDW20UW-05
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

RSDW20UW-05 is the 5V output model of this series: rated power 20W, typical efficiency 85.5%.

RSDW20UW and RDDW20UW series are 20W module type DC-DC reliable railway converter with 2"x1" package. It features international standard pins, a high efficiency up to 89%, wide working temperature range -40~+95℃, 3KVAC I/P-O/P isolation voltage, meet EN50155 with external circuits, continuous-mode short circuit protection, etc. The models account for 8.5~160VDC 18:1 ultra-wide input range, and various output voltage, 5V/12V/15V for single output and ±12V/±15V/±24V for dual outputs, which are suitable for railway, trams, buses and also can be used in the harsh environment with high vibration, high dust, extremely low or high temperature, etc.

Features

  • Compliance with railway standard EN50155
  • DIP 2"x1" package with standard pinout
  • 18:1(8.5~160Vdc) ultra-wide input range
  • Wide operating temperature range -40 ~ +95℃
  • No minimum load required
  • Full encapsulated
  • Protections: Short circuit (Continuous) / Overload / Over Voltage / Input under voltage
  • 3KVAC I/O isolation
  • Operating altitude up to 5000 meters (Note.5)
  • Remote ON/OFF control
  • 3 years warranty

Specifications

RSDW20UW-05Specifications from the official datasheet (2024-11-18 edition)

MODEL SELECTION TABLE

INPUT VOLTAGE (RANGE)
Normal 12V,24V,48V,72V,96V,110V (8.5 ~ 160V)
INPUT CURRENT NO LOAD
5mA
INPUT CURRENT FULL LOAD
323mA
OUTPUT VOLTAGE
5V
OUTPUT CURRENT
4000mA
EFFICIENCY (Typ.)
85.5%
CAPACITOR LOAD (MAX.)* For each output
6800μF

INPUT

VOLTAGE RANGE
8.5 ~ 160Vdc
SURGE VOLTAGE (100ms max.)
200Vdc
FILTER
Pi type
PROTECTION
4A fast acting fuse

OUTPUT

VOLTAGE ACCURACY
±1.0%
RATED POWER
20W
RIPPLE & NOISENote.2
100mVp-p
LINE REGULATIONNote.3
±0.2%
LOAD REGULATIONNote.4
Single output models: ±0.3%, Dual output models:±1%
CROSS REGULATION
±5% @ 25%~100% load
SWITCHING FREQUENCY (Typ.)
200KHz
EXTERNAL TRIM ADJ. RANGE (Typ.)
-20% ~ +15% (Single output model only)

PROTECTION

SHORT CIRCUIT
Protection type : Continuous, automatic recovery
OVERLOAD
110 ~ 180% rated output power Protection type : Recovers automatically after fault condition is removed
OVER VOLTAGE
Protection type : Clamp by diode
UNDER VOLTAGE LOCKOUT Start-up voltage
9Vdc
UNDER VOLTAGE LOCKOUT Shutdown voltage
8Vdc

FUNCTION

REMOTE CONTROL
Power ON: >4.0~160Vdc or open circuit Power OFF: <1.2Vdc or short

ENVIRONMENT

COOLING
Free-air convection
WORKING TEMP.
-40 ~ +95℃ (Refer to "Derating Curve")
CASE TEMPERATURE
+105℃ max. (+110℃ thermal shutdown)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-55 ~ +125℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
0.03% / ℃ (0 ~ 95℃)
SOLDERING TEMPERATURE
1.5mm from case of 1 ~ 3sec./260℃ max.
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
OPERATING ALTITUDENote.5
5000 meters

SAFETY & EMC ( Note.6)

SAFETY STANDARDS
UL62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
ISOLATION CAPACITANCE (Typ.)
20pF
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN50121-3-2Class A/B with external components
RadiatedBS EN/EN50121-3-2N/A
EMC IMMUNITY
ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, ±8KV air, ±6KV contact
Radiated SusceptibilityBS EN/EN61000-4-3Level 3, 80~1000MHz, 20V/m
EFT/BurstsBS EN/EN61000-4-4Level 3, On power input port,±2KV external input capacitor required
SurgeBS EN/EN61000-4-5Level 4, Line to earth, ±4KV Line to Line, ±2KV
ConductedBS EN/EN61000-4-6Level 3, 0.15~80MHz, 10V
RAILWAY STANDARD
EN50155 including EN61373 for shock & vibration, EN50121-3-2 for EMC

OTHERS

MTBF
1570Khrs MIL-HDBK-217F(25℃)
DIMENSION (L*W*H)
50.8*25.4*10.2mm (2*1*0.4 inch)
CASE MATERIAL
Black coated copper with Non-Conductive Base
PACKING
35g ; 12pcs/per tube, 300pcs/25 tube/per carton
Test conditions and notes6
  1. 1.All parameters are specified at normal input(72Vdc), rated load, 25℃ 70% RH ambient.
  2. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
  3. 3.Line regulation is measured from low line to high line at rated load.
  4. 4.Load regulation is measured from 0% to 100% rated load.
  5. 5.The ambient temperature derating of 3.5℃/1000m for operating altitude higher than 2000m(6500ft).
  6. 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)

Technical drawings

RSDW20UW-05 Illustration (page 4)
Illustration (page 4)
RSDW20UW-05 Table 1 – The typical value of Rtrim-up
Table 1 – The typical value of Rtrim-up
RSDW20UW-05 Table 2 – The typical value of Rtrim-down
Table 2 – The typical value of Rtrim-down
RSDW20UW-05 Mechanical Specification
Mechanical Specification
RSDW20UW-05 EMC Suggestion Circuit
EMC Suggestion Circuit
RSDW20UW-05 Packing
Packing

Typical applications

  • Bus, tram, metro or railway system
  • Telecom/datacom system
  • Wireless network
  • Industrial control facility
  • Instrument
  • Analyzer
  • Highly vibrating, heavily dusty, extremely low or high temperature harsh environment

Downloads

FAQ

Can I use the RSDW20UW-05 for 5V industrial electronics where the input source varies widely?

Yes. This model provides a constant 5V output up to 4A and 20W, and its specified input range is 8.5~160Vdc, which is wider than the standard RSDW20H models. That makes it suitable for 5V electronics operating from sources that fall anywhere within that stated range.

Is the RSDW20UW-05 appropriate for 5V embedded systems in heavy-duty or railway-related equipment?

It can be used for 5V embedded loads that require up to 4A and 20W. The provided features include EN50155 railway compliance, 3KVAC isolation, and an operating temperature range of -40°C to +95°C.

Can this converter support 5V display, logging, or communication modules in mobile equipment?

It is a fit for 5V display, logging, or communication modules if the total load remains at or below 4A and 20W. The 8.5~160Vdc input range can be useful in equipment where the available input varies across a broad specified range.

Is the RSDW20UW-05 suitable for outdoor or high-temperature environments?

The operating temperature range is -40°C to +95°C, so it supports a wider temperature span than the RSDW20H series. No IP rating is listed in the specs, so outdoor exposure still requires a protective enclosure.

How does the RSDW20UW-05 compare with the other ultra-wide input versions?

The RSDW20UW-05, -12, and -15 all share 20W power, 8.5~160Vdc input, 50.8 × 25.4 × 10.2 mm dimensions, 35g weight, and -40°C to +95°C operation. Their output ratings differ: the -05 is 5V at 4A, the -12 is 12V at 1.67A, and the -15 is 15V at 1.33A.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8442677559595, "variants" :[{ "context":"default", "variant_id": 45712131588395, "sku":"RSDW20UW-05", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well RSDW20UW-05 Ultra-wide input DC/DC LED Driver 20W 5V - Heavy Duty 4A
Mean Well

Mean Well RSDW20UW-05 Ultra-wide input DC/DC LED Driver 20W 5V - Heavy Duty 4A

RSDW20UW-05 is the 5V output model of this series: rated power 20W, typical efficiency 85.5%.

RSDW20UW and RDDW20UW series are 20W module type DC-DC reliable railway converter with 2"x1" package. It features international standard pins, a high efficiency up to 89%, wide working temperature range -40~+95℃, 3KVAC I/P-O/P isolation voltage, meet EN50155 with external circuits, continuous-mode short circuit protection, etc. The models account for 8.5~160VDC 18:1 ultra-wide input range, and various output voltage, 5V/12V/15V for single output and ±12V/±15V/±24V for dual outputs, which are suitable for railway, trams, buses and also can be used in the harsh environment with high vibration, high dust, extremely low or high temperature, etc.

Features

  • Compliance with railway standard EN50155
  • DIP 2"x1" package with standard pinout
  • 18:1(8.5~160Vdc) ultra-wide input range
  • Wide operating temperature range -40 ~ +95℃
  • No minimum load required
  • Full encapsulated
  • Protections: Short circuit (Continuous) / Overload / Over Voltage / Input under voltage
  • 3KVAC I/O isolation
  • Operating altitude up to 5000 meters (Note.5)
  • Remote ON/OFF control
  • 3 years warranty

Typical applications

  • Bus, tram, metro or railway system
  • Telecom/datacom system
  • Wireless network
  • Industrial control facility
  • Instrument
  • Analyzer
  • Highly vibrating, heavily dusty, extremely low or high temperature harsh environment
View product