NSP-750-12 is the 12V output model of this series: rated current 62.5A, rated power 750W, typical efficiency 92%.
The NSP-750 series is a 750W AC/DC power supply with PFC function, designed for high reliability and suitable for multiple industries. Key features include: compact size (199*105*41 mm) for better space utilization in system installations, ultra-wide input range of 85~305Vac for global compatibility, up to 95% efficiency and low standby power consumption (<0.75W~1W by models) for energy-saving and carbon reduction, constant current design with 200% peak power capability, wide operating temperature range from -40 to +85℃ (+60℃ at full load), compliance with OVC III, built-in Remote Control/Remote Sense/DC OK signal, internal PCB coating, complete protections, certifications for multiple safety standards including 62368-1, 60601-1, 61558-1, 60335-1, 62477-1, and 61010-1, as well as 2 X MOPP compliance and extremely low leakage current (<350μA). It is suitable for BF-rated medical equipment and comes with a 5-years warranty, making it a highly cost-effective solution for industrial power supply needs.
Features
- 85~305Vac input with PFC(277Vac available)
- No load power consumption <0.75W~1W by R.C.
- Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1, Industrial 61558-1/-2-16/61010-1, Energy converter 62477-1)
- 200% peak power capability(12~60V models)
- High efficiency up to 95%
- -40~+85℃ wide range operation temperature(> +60℃ derating)
- Extremely low leakage current<350μA, 2 x MOPP, suitable for BF medical applications
- Built-in constant current limiting circuit
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC fan with noise <45dB and fan ON/OFF control
- Built-in Remote ON/OFF control/Remote Sense/ DC OK signal
- Over voltage category Ⅲ (OVC Ⅲ)
- Operating altitude up to 5000 meters
- Conformal coating
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 62.5A
- CURRENT RANGE
- 0 ~ 62.5A
- RATED POWER
- 750W
- PEAK CURRENT(5 sec.)
- 125A
- PEAK POWER(5 sec.)
- 1500W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- 10.8 ~ 14V
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1500ms, 80ms/115Vac 1000ms, 80ms/230Vac 900ms, 80ms/277Vac
- HOLD UP TIME (Typ.)
- 16ms at full load
INPUT
- VOLTAGE RANGENote.4
- 85 ~ 305Vac 120 ~ 431Vdc
- NO LOAD POWER CONSUMPTION(Typ.) Remote Power OFF
- 0.75W/115Vac 0.75W/230Vac 1W/277Vac
- NO LOAD POWER CONSUMPTION(Typ.) Remote Power ON
- 5W/115Vac 5W/230Vac 5W/277Vac
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115Vac PF>0.93/230Vac PF>0.9/277Vac at full load
- EFFICIENCY (Typ.)
- 92%
- AC CURRENT (Typ.)
- 8.2A/115Vac 3.9A/230Vac 3.2A/277Vac
- INRUSH CURRENT (Typ.)
- COLD START 20A/115Vac 40A/230Vac 50A/277Vac
- LEAKAGE CURRENT
- Earth leakage current <350μA(rms)@277Vac, touch current<100μA(rms) @ 277Vac
PROTECTION
- SHORT CIRCUIT 5V
- Constant current limiting for more than 5 seconds (Vout<30%) and then hiccup mode, recovers automatically after faul condition is removed
- SHORT CIRCUIT 12V ~ 60V
- Constant current limiting for more than 5 seconds (Vout<30%) and then shut down o/p voltage, AC re-power on to recover or Hiccup mode, recovery automatically after fault conditon is removed. Depends on the user's wire impedance
- OVERLOAD 5V
- 105%~150% rated output power; More than 5 seconds and then hiccup mode,recovers automatically after fault condition is removed
- OVERLOAD 12V ~ 60V
- Normally works within 105 ~ 200% rated output power for more than 5 seconds and then constant current limiting without shutdown(Vout>30%), recovers automatically after fault condition is removed, or shut down o/p voltage when Vout<30%,AC re-power on to recover >200% rated power, constant current limiting (Vout>30%)with auto-recovery after fault condition is removed, or shut down o/p voltage when Vout<30%,AC re-power on to recover
- OVER VOLTAGE
- 15 ~ 19V Protection type : Shut down o/p voltage, AC re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- AUXILIARY POWER
- 5Vaux @ 0.2A Tolerance -15% ~ +15% at main output 20% rated current 12Vaux @ 0.8A Tolerance -15% ~ +15% at main output 20% rated current
- REMOTE CONTROL
- POWER ON : short between RC+(pin11)&5V-AUX(pin13) on CN1 POWER OFF: open between RC+(pin11)&5V-AUX(pin13) on CN1
- REMOTE SENSE
- Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual
- DC OK SIGNAL
- By phototransistor contact rating(max.):15Vdc/10mA resistive load. Please refer to the Function Manual.
- FAN NOISE(Typ.)
- Fan ON/OFF control, RTH3≥50℃±10℃ FAN ON;RTH3≤40℃±10℃ FAN OFF 45dB
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05%/℃ (0 ~ 60℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.5&6&7
- CB IEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC61010-1/-2-201, IEC60601-1; IEC62477-1 DEKRA BS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN61010-1/-2-201, BS EN/EN60601-1(3.2 Version);BS EN/EN62477-1 UL UL62368-1, ANSI/AAMI ES60601-1(3.2 Version),UL61010-1/-2-201 CCC GB4943.1 BSMI CNS15598-1 EAC TP TC 004 SEMI F47 approved; KC/BIS KC62368-1 and BIS IS 13252(Part 1) certified, No stock ,contact sales by request
- ISOLATION LEVELNote.8
- Primary-Secondary: 2xMOPP, Primary-Earth: 1xMOPP, Secondary-Earth: 1xMOPP
- OVER VOLTAGE CATEGORYNote.9
- IEC/EN 61558-1/-2-16 (OVC Ⅲ , altitude up to 2000M) IEC/EN/UL 62368-1 (OVC Ⅱ, altitude up to 5000M) IEC/EN 60335-1 (OVC Ⅱ, altitude up to 5000M) IEC/EN/ANSI/AAMI ES60601-1 (OVC Ⅱ, altitude up to 4000M) IEC/EN/UL 61010-1/-2-201 (OVC Ⅱ, altitude up to 5000M) IEC/EN 62477-1 (OVC Ⅱ, altitude up to 5000M)
- SAFETY EXTRA-LOW VOLTAGE(SELV)
- IEC/EN 61558-2-16 (SELV, 5 ~ 36V) IEC/EN 60335-1 (SELV, 5 ~ 36V) IEC/EN/UL 62368-1 (SELV/ES1, 5 ~ 36V)
- WITHSTAND VOLTAGE
- I/P-O/P:4.2KVac I/P-FG:2.1KVac O/P-FG:1.5KVac
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32),CNS 15936,GB/T 9254.1,KS C 9832 Class B Conducted BS EN/EN55014-1(CISPR14-1) Conducted BS EN/EN55011(CISPR11) Class B Radiated BS EN/EN55032(CISPR32),CNS 15936,GB/T 9254.1,KS C 9832 Class B Radiated BS EN/EN55014-1(CISPR14-1) Radiated BS EN/EN55011(CISPR11) Class B Harmonic Current BS EN/ EN61000-3-2(IEC61000-3-2),GB 17625.1 Class A Voltage Flicker BS EN/ EN61000-3-3(IEC61000-3-3) - EMC IMMUNITY
-
BS EN/EN55035( CISPR35 ),BS EN/EN61000-6-2(IEC61000-6-2),B S EN/EN60601-1-2(IEC60601-1-2), BS EN/EN55014-2(CISPR14-2),KS C 9835,SEMI F47 tested at 200Vac
Parameter Standard Test Level ESD BS EN/ EN61000-4-2 Level 4, 15KV air; Level 4, 8KV contact Radiated BS EN/ EN61000-4-3 Level 3, 10V/m(80MHz~2.7GHz) Table 9, 9~28V/m(385MHz~5.78GHz) EFT / Burst BS EN/ EN61000-4-4 Level 3, 2KV Surge BS EN/ EN61000-4-5 Level 4, 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/ EN61000-4-6 Level 3, 10V Magnetic Field BS EN/ EN61000-4-8 Level 4, 30A/m Voltage Dips and Interruptions BS EN/ EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 1047.1 K hrs min. Telcordia SR-332 (Bellcore) ; 137.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION (L*W*H)
- 199*105*41mm
- PACKING
- 1.23Kg;9pcs/12.1Kg/0.63 CUFT
Certifications & ratings
- SEMI F47
- Voltage Sag Immunity Characteristics Verified
Test conditions and notes9
- 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
- 3. Tolerance: includes set up tolerance, line regulation and load regulation.
- 4. Derating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 5. The Regulatory Compliance Mark (RCM) is applied on a voluntary basis. The equipment meets the relevant IEC or AS/NZS standards, or AS/NZS 3820 where applicable. The use of the RCM mark complies with AS/NZS 4417.1.
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. Some factory or model may not have the BIS logo, please contact your MEAN WELL sales for more information.
- 8. MOPP is suitable for 100-240Vac input only.
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft)..
Technical drawings
Typical applications
- Industrial automation machinery/control system
- Security system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- Network equipment
- Telecom devices
- Power sourcing equipment of PoE
- Home automation
- Medical devices
- Charging application
Downloads
Datasheet1
FAQ
What is the output rating of the Mean Well NSP-750-12?
The NSP-750-12 is a 750W enclosed AC/DC power supply with a 12V DC output. Its rated output current is 62.5A, making it suitable for high-current 12V industrial and system-level applications. This model is part of Mean Well's high-reliability NSP-750 series.
What types of applications is the NSP-750-12 designed for?
Mean Well positions the NSP-750-12 for demanding multi-industry use, including industrial automation, telecommunications, medical equipment, mechanical systems, and home automation. Its high power output, remote control features, and DC OK signal make it a fit for monitored and integrated power systems. The 12V version is best considered where a regulated 12V supply with substantial current capacity is required.
Is the NSP-750-12 suitable for harsh industrial environments?
Yes, this model is built for challenging operating conditions. It supports an operating temperature range from -40°C to +85°C and is rated for high-altitude installation up to 5000 meters under the stated overvoltage categories. Output derating applies according to the datasheet derating curve, so performance planning should account for elevated ambient temperatures.
What reliability and protection features does the NSP-750-12 include?
The NSP-750-12 includes short circuit, overload, overvoltage, and overtemperature protection, along with constant current limiting. It also provides a DC OK signal for system monitoring, remote ON/OFF control, and remote sense for output compensation. These features support higher-reliability use in monitored industrial and medical-related equipment designs.
How does the NSP-750-12 compare with standard enclosed power supplies?
Compared with basic enclosed power supplies, the NSP-750-12 stands out for its broad 85-305VAC input range, active PFC, 92% typical efficiency, and 200% peak power capability for up to 5 seconds. It also adds higher-end control and monitoring features such as remote ON/OFF, remote sense, auxiliary outputs, and DC OK signaling. The series is aimed at higher-reliability applications rather than general low-cost power conversion.
Does the NSP-750-12 support medical or compliance-sensitive applications?
This model includes very low leakage current below 350 microamps and carries 2xMOPP medical safety approval. It is also listed to multiple industrial, household, medical, and energy-conversion safety standards. That makes it relevant for compliance-sensitive equipment where certified power hardware is important.
What cooling and form factor should buyers expect from the NSP-750-12?
The NSP-750-12 uses forced-air cooling with a built-in temperature-controlled fan. Its compact enclosure measures 199 x 105 x 41 mm and weighs 1.23 kg. This combination supports high power density while keeping the unit suitable for enclosed equipment builds that need a slim 750W power supply.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.