Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HEP-1000-48 is the 48V output model of this series: rated current 21A, rated power 1008W, typical efficiency 96%.
HEP-1000 is a 1000W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted glue. Adopting the full range 90~305Vac input, the entire series provides an output voltage line of 24V, 48V and 100V. In addition to the high efficiency up to 96%, that the whole series operates from -40℃ ~ +70℃ under air convection without fan. HEP-1000 has the complete protection functions and 10G anti-vibration capability; It is complied with the international safety regulations such as TUV BS EN/EN62368-1 UL62368-1, and the design refers to BS EN/EN61558-1 and BS EN/EN60335-1HEP-1000 series serves as a high performance power supply solution for various industrial and charger applications.
Features
- 90 ~ 305Vac input with PFC
- Power or charger mode switchable by SBP-001(Terminal type)
- High efficiency up to 96%
- Aluminum case fanless design and filling with heat-conducted glue and able to withstand 10G vibration test
- Wide operating temperature range -40 ~ +70℃
- Charger for lead-acid batteries (flooded, Gel and AGM) and Li-ion batteries (lithium iron and lithium manganese)
- Built-in default 2/3 stage charging curves and programmable curve
- Built-in PMBus (Terminal type) / CANBus protocol
- Output voltage and constant current level programmable
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in remote ON-OFF control (Terminal type)
- DC OK active signal and 12V Auxiliary power available
- LED indicator for power on (Terminal type)
- IP67 design for indoor or outdoor installation (Wiring type)
- 6 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 21A
- RATED POWER
- 1008W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGE
- By built-in potentiometer, SVR
- VOLTAGE ADJ. RANGE
- 48 ~ 60V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1800ms, 80ms at full load 230Vac /115Vac
- HOLD UP TIME (Typ.)
- 16ms / 230Vac at 75% load 12ms / 230Vac at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 305Vac 250 ~ 431Vdc
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.99/115Vac, PF>0.95/230Vac, PF>0.93/277Vac at full load
- EFFICIENCY (Typ.)
- 96%
- AC CURRENT (Typ.)
- 10.1A / 115Vac 5.3A / 230Vac 4.5A / 277Vac
- INRUSH CURRENT(Typ.)
- Cold start 40A at 230Vac
- LEAKAGE CURRENT
- <0.75mA / 240Vac
PROTECTION
- OVERLOAD
- 105~125% rated current Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover
- SHORT CIRCUIT
- Constant current limiting, unit will shutdown after 5 sec, re-power on to recover
- OVER VOLTAGE
- 60 ~ 70V Protection type :Shut down O/P voltage,re-power on to recover
- OVER TEMPERATURE
- Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION
- OUTPUT VOLTAGE PROGRAMMABLE(PV)Note 5
- Adjustment of output voltage is allowable to 50 ~ 125% of nominal output voltage Please refer to the Function Manual.
- OUTPUT CURRENT PROGRAMMABLE(PC)Note 5
- Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.
- REMOTE ON/OFF CONTROL
- Power ON : Short circuit Power OFF : Open circuit
- AUXILIARY POWER
- 12V @ 0.5A tolerance ±10%, ripple=150mVp-p
- DC-OK SIGNAL
- The TTL signal out, PSU turn on = 4.4 ~ 5.5Vdc ; PSU turn off = -0.5 ~ 0.5Vdc. Please refer to the Function Manual.
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC (Note.7)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, BIS IS13252(Part1): 2010/IEC 60950-1:2005(NOTE 9), EAC TP TC 004 approved; design refer to BS EN/EN61558-1, BS EN/EN60335-1(by request)
- WITHSTAND VOLTAGE
- I/P-O/P:3KVac I/P-FG:2KVac O/P-FG:1.25KVac
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500Vdc/25℃/ 70%RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) Class B Radiated BS EN/EN55032 (CISPR32) Class B Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55024 , BS EN/EN61000-6-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-6-2 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 583.7K hrs min. Telcordia SR-332 (Bellcore) ; 52.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 310*144*48.5mm (L*W*H)
- PACKING
- 4Kg;4pcs/18.25Kg/1.04CUFT
BATTERY CHARGER MODE OUTPUT (Can be configured to charger mode by PMBus, CANBus or SBP-001)
- BOOST CHARGE VOLTAGE Vboost
- 57.6V
- FLOAT CHARGE VOLTAGE Vfloat
- 55.2V
- RECOMMENDED BATTERY CAPACITY(AMP HOURS)Note 2 (charger mode): This is Mean Well's suggested range. Please consult your battery manufacturer for their suggestions about maximum charging current limitation.
- 60 ~ 175AH
- BATTERY TYPE
- Open & Sealed Lead Acid
- OUTPUT CURRENT
- 17.5A
BATTERY CHARGER MODE SAFETY & EMC (Note.5)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, EAC TP TC 004 approved; design refer to BS EN/EN61558-1, BS EN/EN60335-1(by request)
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) Class B Radiated BS EN/EN55032 (CISPR32) Class A Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3
Test conditions and notes9
- 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance :includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. PV/PC functions when users do not use SVR.
- 6. In power mode: When O/P voltage is below < 80% of Vset for 5 sec. the unit will shut down afterwards.
- 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 9. Some model may not have the BIS logo, please contact your MEAN WELL sales for more information.
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system at harsh environment
- Mechanical and electrical equipment
- Electronic instruments, equipments
- 5G telecom equipments
- Robotic lawn mower/AMR/AGV
- Equipments or instruments with back-up battery
Downloads
Certificates8
Test reports1
Catalogues1
FAQ
Can I use the HEP-1000-48 for a 48V industrial or telecom-style DC system?
Yes, if the load requires constant-voltage 48V DC and stays within 21A and 1008W. Those specs fit higher-power 48V industrial, communications, embedded, and automation systems that are designed for a 48V DC bus.
Is the HEP-1000-48 suitable for a centralized 48V power architecture?
It is designed for exactly that kind of constant-voltage 48V application, with 1008W total output capacity and 21A available. That gives it enough capacity for larger centralized 48V systems.
Can this supply handle demanding 48V automation equipment in a rugged enclosure?
It can support 48V DC equipment up to 21A and 1008W, and the IP67-rated HEP-1000 series is built for harsh environments. Mean Well also lists 10G vibration tolerance and 96% typical efficiency, which are relevant in industrial enclosures and field equipment.
Is the HEP-1000-48 rated for outdoor operation?
Yes, it has an IP67 rating, so it is suited to outdoor and wet environments where dust and water exposure are concerns. Its operating temperature range is -40°C to +70°C (refer to the derating curve) for cold and hot site conditions.
What are the output differences across the HEP-1000 models?
The listed HEP-1000 variants are 24V at 42A and 1008W, 48V at 21A and 1008W, and 100V at 10A and 1000W. The HEP-1000-48 sits between the 24V and 100V versions in output voltage, and its 21A output current is between the 42A and 10A figures of those two models.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.