Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well HEP-480-48A Power Supply 321.6W 48V 10A
Overview
HEP-480-48A is the 48V output model of this series: rated current 10A, rated power 480W, typical efficiency 94.5%.
HEP-480 is a 480W industrial AC/DC power supply featuring the outstanding capability to operate under highly humid, dusty, oily, and high-vibration harsh environment. The entire series is housed with the aluminum case and fully potted with heat-conducted silicone. Thanks to state-of-the-art design, the working efficiency is up to 95%, enabling HEP-480 perfectly work between -55℃ and +65℃ under free air convection.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 95%
- Fanless design, cooling by free air convection
- -55~+65℃ wide operating range
- Aluminum case and filling with heat-conducted silicone
- IP65 design, optional IP68 rated model available
- Meet 6KV surge immunity level
- Withstand 10G vibration test
- Operating altitude up to 5000 meters (Note.7)
- Protections: Short circuit / Overload / Over voltage / Over temperature
- 6 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 10A
- RATED POWER
- 480W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGENote.5
- 40.8 ~ 50.4V
- CURRENT ADJ. RANGE
- 5 ~ 10A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.4
- 500ms, 80ms 115VAC/230VAC
- HOLD UP TIME (Typ.)
- 16ms 115VAC/230VAC
INPUT
- VOLTAGE RANGENote.5
- 90~264VAC (277VAC operational) 128~370VDC(390VDC operational)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/115VAC, PF≧0.97/230VAC, PF≧0.95/277VAC at full load
- EFFICIENCY (Typ.)
- 94.5%
- AC CURRENT (Typ.)
- 5A / 115VAC 2.45A / 230VAC 2A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 35A at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENT
- 105 ~ 125% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 53 ~ 63V Shut down output voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down output voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -55 ~ +65℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -60 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.02%/℃ (0 ~ 60℃)
- VIBRATION
- 20 ~ 500Hz, 10G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.7
- UL62368-1,IEC62368-1, IP65 (or IP68 for HEP-480 Blank-Type), EAC TP TC 004 approved ;Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level (surge 6KV), EAC TP TC 020
OTHERS
- MTBF
- 1036.8K hrs min. Telcordia SR-332 (Bellcore) ; 89.8Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 262*125*43.8mm (L*W*H)
- PACKING
- 2.8Kg;4pcs/11.5Kg/0.55CUFT
Test conditions and notes9
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the setup time.
- 5. Derating may be needed under low input voltages. Please refer to the “STATIC CHARACTERISTICS” for more details.
- 6. The power supply shall be regarded as one component of the final system. The EMC performance will be affected by the complete system installation and/or configuration, the final system manufacturers must re-verify overall EMC directive with the complete installation and/or configuration. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. The water protection level test for the IP68 rating is performed 1000mm below the surface of the water for 1 month.
- 8. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Outdoor telecommunication equipment
- Outdoor electronic signage and billboard
- Petroleum plant or mine shaft facility
Downloads
Certificates5
Test reports1
Catalogues1
FAQ
Can the HEP-480-48A be used for 48V industrial control systems?
Yes, if the control system requires constant-voltage 48V DC and the total load stays within 10A. With 480W output capacity, it fits larger 48V control assemblies better than lower-power 48V supplies in the same series.
Is this power supply appropriate for 48V IT or communications equipment?
It can be appropriate for IT or communications hardware designed for a regulated 48V DC source. The unit delivers 48V constant voltage with up to 480W output, and its 90-264VAC input (277VAC operational) supports use across a broad range of AC input conditions.
Can I use the HEP-480-48A in embedded or OEM equipment that needs a sealed 48V supply?
Yes, for OEM or embedded builds that require 48V DC constant-voltage power up to 10A. The IP65 rating, 94.5% typical efficiency, and 10G vibration specification can be useful in enclosed equipment where durability matters.
Is the HEP-480-48A meant for outdoor or washdown-prone environments?
This model is rated IP65 water-resistant and operates from -55°C to +65°C (with load derating at higher temperatures), so it is suitable for demanding indoor areas and outdoor locations with exposure to dust and water spray. It is also specified to withstand 10G vibration, which supports use in harsher industrial conditions.
How does the HEP-480-48A sit within the 48V HEP lineup?
On the HEP-480 sheet, 48V output comes in two versions: the HEP-480-48A and the HEP-480-48, both 480W at 10A. The HEP-480-48A is the A-type with built-in potentiometers for 40.8-50.4V voltage and 5-10A current adjustment and an IP65 rating, while the Blank-Type HEP-480-48 is rated IP68 without adjustment.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HEP-480 Models
7 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HEP-480-54A Power Supply 321.3W 54V 8.9A | 480.6W | 54V | 8.9A | View |
| Mean Well HEP-480-54 Power Supply 321.3W 54V 8.9A | 480.6W | 54V | 8.9A | View |
| Mean Well HEP-480-48 Power Supply 321.6W 48V 10A | 480W | 48V | 10A | View |
| Mean Well HEP-480-36A Power Supply 320.4W 36V 13.3A | 478.8W | 36V | 13.3A | View |
| Mean Well HEP-480-36 Power Supply 320.4W 36V 13.3A | 478.8W | 36V | 13.3A | View |
| Mean Well HEP-480-24A Power Supply 320.16W 24V 20A | 480W | 24V | 20A | View |
| Mean Well HEP-480-24 Power Supply 320.16W 24V 20A | 480W | 24V | 20A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.