Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well LRS-600N2-12 Single Output High Peak Power Supply 600W 12V, 2 Times Peak Power 50A
4.7 (17 reviews)Overview
LRS-600N2-12 is the 12V output model of this series: rated current 50A, rated power 600W, typical efficiency 90%.
LRS-600N2 series is a 600W single-output enclosed type power supply with 41mm of low profile design. Adopting the input of 115VAC or 230VAC (select by switch), the entire series provides an output voltage line of 12V, 24V, 36V and 48V.In addition to the high efficiency up to 92%, with the built-in long life fan LRS-600N2 can work under -20~+65β with full load. LRS-600N2 has the complete protection functions and 5G anti-vibration capability; It is complied with complete international safety regulations. LRS-600N2 series serves as a high price-performance power supply solution for various industrial applications. Moreover, LRS-600N2 can provide 200% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Features
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 second
- Up to 200% peak power capability
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Forced air cooling
- Built-in cooling Fan ON-OFF control
- Compliance to IEC/BS EN/EN61558-1 and 62368-1
- Withstand 5G vibration test
- Over voltage category β ’(OVC β ’)
- High operating temperature up to 65β
- Operating altitude up to 2000 meters
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 50A
- CURRENT RANGE
- 0 ~ 50A
- RATED POWER
- 600W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGENote.3
- 11.4 ~ 13.2V
- VOLTAGE TOLERANCE
- Β±1.5%
- LINE REGULATION
- Β±0.5%
- LOAD REGULATION
- Β±1.0%
- SETUP, RISE TIMENote.4
- 1300ms, 50ms/230VAC 1300ms,50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 20ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 132VAC / 180 ~ 264VAC by switch 255 ~ 370VDC (swith on 230VAC)
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 90%
- AC CURRENT (Typ.)
- 12A/115VAC 7.5A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 60A/230VAC
- LEAKAGE CURRENT
- <2mA / 240VAC
PROTECTION
- OVER LOAD
- Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover Constant current limiting for output power >200% rated for more than 5 seconds and then shut down o/p voltage, re-power on to recover
- OVER VOLTAGE
- 13.8 ~ 16.2V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
FUNCTION
- FAN ON/OFF CONTROL (Typ.)
- RTH3β§50β FAN ON, β¦40β FAN OFF
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +65β (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85β, 10 ~ 95% RH
- TEMP. COEFFICIENT
- Β±0.03%/β (0 ~ 50β)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
- OVER VOLTAGE CATEGORY
- β ’:According to EN61558,EN50178,EN60664-1,EN62477-1;altitude up to 2000 meters
SAFETY & EMC
- SAFETY STANDARDS
- BS IEC/UL 62368-1, EAC TP TC 004, BIS IS13252(Part1):2010/IEC60950-1:2005(except for 48V), BSMI CNS15598-1,GB 4943.1, BS EN/EN61558-1,BS EN/EN61558-2-16, design refer to AS/NZS61558.1/2.16,AS/NZS62368.1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC / 25β/ 70% RH
- EMC EMISSION
- Compliance to EAC TP TC 020, BSMI CNS15936
- EMC IMMUNITY
- Compliance to EAC TP TC 020
OTHERS
- MTBF
- 1336.2K hrs min. Telcordia SR-332(Bellcore) ; 230.8 K hrs min. MIL-HDBK-217F (25β)
- DIMENSION
- 225*124*41mm (L*W*H)
- PACKING
- 0.95Kg/12pcs/12.4Kg/0.77CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25β of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Voltage adjustment can only be operated within the input range of 100~120VAC or 200-240VAC. If the voltage adjustment is performed outside this range, it may cause abnormal output.
- 4. Length of set up time is measured at cold start. Turning the power supply on/off frequently may lead to increase of the set up time.
- 5. Once protections are triggered, 4min(Typ.) of cold down time is required before restart.
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to βEMI testing of component power supplies.β (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. This power supply does not meet the harmonic current requirements outlined by EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W
- 8. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- For Inductive and capacitive load
Downloads
Datasheet1
FAQ
What is the peak power capability of the LRS-600N2-12 and when does it activate?
The LRS-600N2-12 can deliver up to 200% of its rated 600W output (approximately 1200W) for peaks of up to 5 seconds, at a duty cycle of no more than 35% and with average power kept within the 600W rating; the available peak level depends on input voltage (see the peak-power curve). This covers short surges such as motor startup, capacitor charging, or solenoid engagement without requiring a larger continuous-rated supply.
How does the LRS-600N2-12 compare to the other LRS-600N2 voltage variants?
All LRS-600N2 models share the same 225 Γ 124 Γ 41 mm case, 0.95 kg weight, 90β132VAC / 180β264VAC switch-selectable input, and 200% peak power capability. Output ratings: LRS-600N2-12 (600W, 50A at 12V), LRS-600N2-24 (600W, 25A at 24V), LRS-600N2-36 (597.6W, 16.6A at 36V), LRS-600N2-48 (600W, 12.5A at 48V).
What temperature range does the LRS-600N2-12 support?
The LRS-600N2-12 operates from -20Β°C to +65Β°C ambient, with output derated at higher temperatures according to the derating curve; enclosures should be designed with adequate airflow to keep the unit within its derated load limits. The -20Β°C lower limit supports operation in most industrial indoor environments.
Is the LRS-600N2-12 appropriate for motor-driven automation systems with frequent start-stop cycles?
Yes, within its peak limits. The combination of 50A continuous output and 200% peak power for up to 5 seconds (duty cycle β€35%, average power within the 600W rating) makes the LRS-600N2-12 well-matched for 12V DC motor systems with startup inrush. The peak feature absorbs short startup surges that would otherwise require oversizing to a higher-wattage supply.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other LRS-600N2 Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well LRS-600N2-48 Single Output High Peak Power Supply 600W 48V, 2 Times Peak Power 12.5A | 600W | 48V | 12.5A | View |
| Mean Well LRS-600N2-36 Single Output High Peak Power Supply 597.6W 36V, 2 Times Peak Power 16.6A | 597.6W | 36V | 16.6A | View |
| Mean Well LRS-600N2-24 Single Output High Peak Power Supply 600W 24V, 2 Times Peak Power 25A | 600W | 24V | 25A | View |
Customer reviews
Reviewed by 17 customers across the LRS series
-
Cheap and reliable enclosed PSU
Model: LRS-50-24Quantity: 10LRS-50-24 powers our sensor rack. Great price, no fuss.
-
Good budget option
Model: LRS-100-24Quantity: 4Runs a bit warm in a sealed box β add airflow. Otherwise solid.
-
Standardised on these
Model: LRS-350-24Quantity: 25Use LRS across all our retail fit-outs now.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your reviewβ¦
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.





