Mean Well MDR-40-5 Single Output Industrial Power Supply 40W 5V 6A - DIN Rail

ultra slimbuilt-in active PFC function
SKU MDR-40-5
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 4 in this family

MDR-40-5
Available to order
|

Overview

MDR-40-5 is the 5V output model of this series: rated current 6A, rated power 30W, typical efficiency 78%.

Features

  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Class I, Div 2 Hazardous Locations T4
  • LED indicator for power on
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test
  • 3 years warranty

Specifications

MDR-40-5Specifications from the official datasheet (2024-10-30 edition)

OUTPUT

DC VOLTAGE
5V
RATED CURRENT
6A
CURRENT RANGE
0 ~ 6A
RATED POWER
30W
RIPPLE & NOISE (max.)Note.2
80mVp-p
VOLTAGE ADJ. RANGE
5 ~ 6V
VOLTAGE TOLERANCENote.3
±2.0%
LINE REGULATION
±1.0%
LOAD REGULATION
±1.0%
SETUP, RISE TIMENote.5
500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
50ms/230VAC 20ms/115VAC at full load

INPUT

VOLTAGE RANGE
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
78%
AC CURRENT (Typ.)
1.1A/115VAC 0.7A/230VAC
INRUSH CURRENT (Typ.)
COLD START 30A/115VAC 60A/230VAC
LEAKAGE CURRENT
<1mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
6.25 ~ 7.25V Protection type : Shut down o/p voltage, re-power on to recover

FUNCTION

DC OK SIGNAL
Relay contact rating(max.): 30V/1A resistive

ENVIRONMENT

WORKING TEMP.
-20 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6

SAFETY & EMC

SAFETY STANDARDS
UL508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 ,IS13252(Part1)/IEC60950-1(except 48V)approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EAC TP TC 020

OTHERS

MTBF
2418.5K hrs min. Telcordia SR-332 (Bellcore) ; 301.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
40*90*100mm (W*H*D)
PACKING
0.3Kg; 42pcs/13.6Kg/0.82CUFT
Test conditions and notes6
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  6. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

MDR-40-5 Mechanical Specification
Mechanical Specification
MDR-40-5 Block Diagram
Block Diagram
MDR-40-5 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the MDR-40-5 for 5V PLC logic, controller boards, or industrial electronics?

Yes, this model is suited to 5V DC loads up to 6A, with a listed power rating of 30W. It is appropriate for DIN rail control panels where the electronics specifically require a 5V supply.

Is the MDR-40-5 a good fit for 5V modules inside a control cabinet?

It can be used for grouped 5V industrial electronics as long as the combined draw stays within 30W and 6A. The DIN rail format and 40 mm wide housing help when several components must fit in one enclosure.

Can this 5V power supply be used in building management or automation panels with low-voltage control electronics?

Yes, if the panel includes 5V DC devices and the total load remains within the unit's 30W and 6A output limits. The 85-264VAC input range also suits AC-fed control panels used in automation and facility systems.

Is the MDR-40-5 suitable when I need a slim DIN rail power supply for compact panel layouts?

Yes, the housing measures 40 x 90 x 100 mm (W x H x D) and mounts on TS-35/7.5 or TS-35/15 DIN rail. That makes it useful in compact DIN rail assemblies where a 5V supply must fit into limited panel space.

Should the MDR-40-5 be mounted in an enclosure rather than an exposed location?

This unit is generally intended for use inside a control cabinet or enclosure. The listed operating temperature range is -20C to +70C with output derating at higher ambient temperatures (see the derating curve), and no separate outdoor or washdown protection rating is included in the provided specs.

How does the MDR-40-5 compare with the other MDR series models?

Within the MDR-40 series, the MDR-40-5 is the 5V version at 30W and 6A. The other versions are MDR-40-12 at 12V, 40W and 3.33A, MDR-40-24 at 24V, 40.8W and 1.7A, and MDR-40-48 at 48V, 39.8W and 0.83A. The 5V model has 78% typical efficiency versus 85-88% for the others, and all share the 85-264VAC input and 40 x 90 x 100 mm DIN rail housing.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8318585897259, "variants" :[{ "context":"default", "variant_id": 45222633472299, "sku":"MDR-40-5", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well MDR-40-5 Single Output Industrial Power Supply 40W 5V 6A - DIN Rail
Mean Well

Mean Well MDR-40-5 Single Output Industrial Power Supply 40W 5V 6A - DIN Rail

MDR-40-5 is the 5V output model of this series: rated current 6A, rated power 30W, typical efficiency 78%.

Features

  • Universal AC input/Full range
  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Class I, Div 2 Hazardous Locations T4
  • LED indicator for power on
  • DC OK relay contact
  • No load power consumption<0.75W
  • 100% full load burn-in test
  • 3 years warranty

Model

  • 10W 5V
  • 20W 5V
  • 40W 5V
  • 60W 5V
View product