Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NDR-120-48 is the 48V output model of this series: rated current 2.5A, rated power 120W, typical efficiency 89%.
NDR-120 is one economical slim 120W DIN rail power supply series, adapt to be installed on TS-35/7.5 or TS-35/15 mounting rails. The body is designed 40mm in width, which allows space saving inside the cabinets. The entire series adopts the full range AC input from 90VAC to 264VAC and conforms to BS EN/EN61000-3-2, the norm the European Union regulates for harmonic current. NDR-120 is designed with metal housing that enhances the unit's power dissipation. With working efficiency up to 89%, the entire series can operate at the ambient temperature between -20℃ and 70℃ under air convection. It is equipped with constant current mode for over-load protection, fitting various inductive or capacitive applications. The complete protection functions and relevant certificates for industrial control apparatus (UL508, TUV BS EN/EN62368-1, and etc.) make NDR-120 a very competitive power supply solution for industrial applications.
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 2.5A
- CURRENT RANGE
- 0 ~ 2.5A
- RATED POWER
- 120W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 48 ~ 55V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 1200ms, 60ms/230VAC 2500ms, 60ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 10ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.6
- 90 ~ 264VAC 127 ~ 370VDC [DC input operation possible by connecting AC/L(+), AC/N(-)]
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 89%
- AC CURRENT (Typ.)
- 2.25A/115VAC 1.3A/230VAC
- INRUSH CURRENT (Typ.)
- 20A/115VAC 35A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 130% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 56 ~ 65V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL508, TUV BS EN/EN62368-1, EAC TP TC 004 approved;(meet BS EN/EN60204-1)
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 2636.8K hrs min. Telcordia SR-332 (Bellcore) ; 453.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 40*125.2*113.5mm (W*H*D)
- PACKING
- 0.6Kg; 20pcs/13Kg/1.0CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.(as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
- 6. Derating may be needed under low input voltage. Please check the derating curve for more details.
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical apparatus
Downloads
Certificates4
Test reports1
FAQ
Can I use the NDR-120-48 for a 48V PLC or industrial automation panel?
Yes, this model is a 48V DIN rail power supply rated for 120W and 2.5A output. Its slim 40.0 mm profile and DIN rail format make it a practical fit for compact PLC and industrial automation control panels using 48VDC loads.
Is the NDR-120-48 suitable for building management or access control cabinets that use 48VDC?
It can be a fit for building management and access control cabinets when the system requires 48VDC and stays within 2.5A and 120W. The DIN rail design and 125.2 × 113.5 × 40.0 mm housing suit control cabinet layouts where space is limited.
Can this 48V DIN rail power supply be used in a telecom or network control enclosure?
It is appropriate for telecom or network-related control enclosures that need a 48VDC supply up to 2.5A. The wide 90-264VAC input also helps when the enclosure is being specified for sites with different AC input conditions.
Is the NDR-120-48 meant for open-air use or for enclosed control cabinets?
This DIN rail model is better suited to protected control cabinets and electrical enclosures. The listed operating range is -20°C to +70°C, and the specs call out a metal case, but no ingress rating is provided here for exposed outdoor use.
How does the NDR-120-48 compare with other Mean Well NDR DIN rail models?
Within the NDR range, sibling options are NDR-75-12 at 75.6W 12V 6.3A, NDR-75-24 at 76.8W 24V 3.2A, NDR-75-48 at 76.8W 48V 1.6A, NDR-120-12 at 120W 12V 10A, NDR-120-24 at 120W 24V 5A, NDR-240-24 at 240W 24V 10A, NDR-240-48 at 240W 48V 5A, NDR-480-24 at 480W 24V 20A, and NDR-480-48 at 480W 48V 10A. The NDR-120-48 sits in the 48V branch at 120W with 2.5A output.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NDR-120 Models
2 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well NDR-120-24 Single Output Industrial Power Supply 120W 24V 5A - DIN Rail | 120W | 24V | 5A | IP20 | View |
| Mean Well NDR-120-12 Single Output Industrial Power Supply 120W 12V 10A - DIN Rail | 120W | 12V | 10A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.