Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RPS-200-15 is the 15V output model of this series: typical efficiency 93.5%.
RPS-200 is a 200W highly reliable green PCB type medical power supply with a high power density (21.9W/in³) on the 4″ by 2″ footprint. It accepts 80~264VAC input and offers various output voltages between 12V and 48V. The working efficiency is up to 95% and the extremely low no load power consumption is down below 0.5W. RPS-200 is able to be used for both ClassⅠ(with FG) and ClassⅡ(no FG) system design. The extremely low leakage current is less than 180μ A. In addition, it conforms to the international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated “patient contact” medical system equipment.
Features
- 4"×2" compact size
- Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
- Suitable for BF application with appropriate system consideration
- 140W convection, 200W force air
- EMI Conduction for Class B Radiation for Class B with FG(ClassⅠ) and Class A without FG(ClassⅡ)
- No load power consumption<0.5W
- Extremely low leakage current
- 12V/0.5A fan supply
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Lifetime > 65K hours
- Operating altitude up to 5000 meters
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- CURRENT 10CFM
- 13.4A
- CURRENT Convection
- 9.4A
- RATED POWER 10CFM
- 201W
- RATED POWER Convection
- 141W
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p
- VOLTAGE ADJ. RANGE
- 14.3~15.8V
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 700ms, 30ms/230VAC 700ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 80 ~ 264VAC 113 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF>0.94/230VAC PF>0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 93.5%
- AC CURRENT (Typ.)
- 2A/115VAC 1A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 30A/115VAC 60A/230VAC
- LEAKAGE CURRENT(max.)Note.5
- Earth leakage current < 180μA/264VAC , Touch current < 40μA/264VAC
PROTECTION
- OVERLOAD
- 110 ~ 140% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 16.5 ~ 19.5V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
- FAN SUPPLY
- 12V@0.5A for driving a fan ; tolerance +15% ~ -15% at main output 20% rated current (10CFM)
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
- OPERATING ALTITUDENote.6
- 5000 meters
SAFETY & EMC
- SAFETY STANDARDS
- IEC 60601-1:2005+A1+A2, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2 CAN/CSA C22.2 No. 60601-1:2014+A2, EAC TP TC 004 approved; Design refer to BS EN/EN60335-1(by request)
- ISOLATION RESISTANCE
- Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
- WITHSTAND VOLTAGE
- I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted emission BS EN/EN55011 (CISPR11) Class B Radiated emission BS EN/EN55011 (CISPR11) Class A (for Class II);Class B (for Class I) Harmonic current BS EN/EN61000-3-2 Class A Voltage flicker BS EN/EN61000-3-3 -----; BS EN/EN55035, BS EN/EN60601-1-2 - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 4, 15KV air; Level 4, 8KV contact RF field susceptibility BS EN/EN61000-4-3 Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) EFT bursts BS EN/EN61000-4-4 Level 3, 2KV Surge susceptibility BS EN/EN61000-4-5 Level 4, 4KV/Line-FG; 2KV/Line-Line Conducted susceptibility BS EN/EN61000-4-6 Level 3, 10V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m Voltage dip, interruption BS EN/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods
OTHERS
- MTBF
- 2669.7K hrs min. Telcordia SR-332 (Bellcore) ; 500.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION (L*W*H)
- PCB:101.6*50.8*29mm or 4″*2″*1.14″inch ; Enclosed type:103.4*62*40mm or 4.07″*2.44″*1.57″inch
- PACKING
- PCB:0.19Kg; 72pcs/14.7Kg/0.84CUFT ; Enclosed type:0.3Kg; 60pcs/19Kg/1.06CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. Touch current was measured from primary input to DC output.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Oral irrigator
- Hemodialysis machine
- Medical monitors
- Sleep apnea devices
- Pumps machine
- Electric bed
Downloads
Certificates7
Test reports1
Catalogues1
FAQ
Can I use the RPS-200-15 for a 15V industrial control or instrumentation system?
Yes, this model provides a 15V output of up to 9.4A (141W) with convection cooling, or 13.4A (201W) with 10CFM forced air, for 15V industrial electronics. It is a good fit for protected instrumentation or control assemblies that require a dedicated 15V rail.
Is the RPS-200-15 suitable for 15V analog or embedded electronics?
It can be used for 15V embedded, analog, or measurement electronics that stay within 9.4A with convection cooling, or 13.4A with a 10CFM fan. The wide 80-264VAC input range also supports deployment across varied AC mains conditions.
Can this power supply support 15V medical or laboratory equipment?
Yes, it is identified as a medical power supply and includes medical safety approval. The feature list also calls out extreme low leakage current, which can be relevant for medical and lab equipment designs.
Would the RPS-200-15 work in a compact 15V control enclosure?
Yes, the unit delivers 141W with convection cooling (201W with a 10CFM fan) on a compact 101.6 x 50.8 x 29.0 mm board weighing 0.19 kg. That can make it easier to integrate into compact enclosed systems that need 15V DC power.
Can the RPS-200-15 operate in demanding indoor temperatures?
Its specified operating temperature range is -30°C to +70°C, with output derating at higher ambient temperatures according to the derating curve. Because no IP rating is listed, it should still be installed in protected indoor equipment rather than exposed outdoor environments.
How does the RPS-200-15 compare with the other RPS-200 voltage options?
Within the RPS-200 family, the convection ratings are 140.4W at 11.7A for 12V, 141W at 9.4A for this 15V version, 141.6W at 5.9A for 24V, 143.1W at 5.3A for 27V, and 144W at 3A for 48V; with a 10CFM fan all versions reach about 200W. The `-C` enclosed variants have the same rated outputs as the matching PCB versions.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.