Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RPSG-160-12 is the 12V output model of this series: typical efficiency 87%.
RPS-160 is a 160W highly reliable green PCB type medical power supply with a high power density on a 5" by 3" footprint. It accepts 90~264VAC input and offers various models with the output voltages between 5V and 48V. The working efficiency is up to 88% and the extremely low no load power consumption is down below 0.5W. RPS-160 is able to be used for ClassⅠ(with FG) system design. The extremely low leakage current is less than 200μ A. In addition, it conforms to the international medical regulations (2*MOPP) and EMC BS EN/EN55011, perfectly fitting all kinds of BF rated "patient contact" medical system equipment.
Features
- 5"* 3" compact size
- Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
- Suitable for BF application with appropriate system consideration
- 110W convection, 160W force air
- EMI class B for class Ⅰ configuration
- No load power consumption under 0.5W by PS-ON control (G model)
- 5Vdc standby output, Power Good, Power Fail ; Remote sense for 5~15V
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 3000 meters
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT (20.5CFM)
- 12.9A
- CURRENT Convection
- 0 ~ 9.1A
- CURRENT 20.5CFM
- 0 ~ 12.9A
- RATED POWER ConvectionNote.2
- 112.2W
- RATED POWER 20.5CFMNote.3
- 159.8W
- RIPPLE & NOISE (max.)Note.4
- 80mVp-p
- VOLTAGE ADJ. RANGE(main output)
- 10.8 ~ 13.2V
- VOLTAGE TOLERANCENote.5
- ±3.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 1800ms, 30ms/230VAC 3500ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 20ms/115VAC 25ms/230VAC at full load
INPUT
- VOLTAGE RANGENote.6
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.93/230VAC PF>0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 87%
- AC CURRENT (Typ.)
- 2A/115VAC 1.1A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 35A/115VAC 70A/230VAC
- LEAKAGE CURRENTNote.7
- Earth leakage current < 200μA/264VAC , Touch current < 100μA/264VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 13.8 ~ 16.2V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- TSW1: Shut down o/p voltage, recovers automatically after temperature goes down TSW2: Shut down o/p voltage, re-power on to recover
FUNCTION
- 5V STANDBY (G model)
- 5Vsb : 5V@0.6A without fan, 0.8A with fan 20.5CFM ; Tolerance ± 2%, ripple : 50mVp-p(max.)
- PS-ON INPUT SIGNAL (G model)
- Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V"
- POWER GOOD / POWER FAIL
- 500ms>PG>10ms PF>1ms
- REMOTE SENSE
- 5 ~ 15V
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
- OPERATING ALTITUDENote.8
- 3000 meters
SAFETY & EMC
- SAFETY STANDARDS
- IEC 60601-1:2005+A1+A2, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2 CAN/CSA C22.2 No. 60601-1:2014+A2, EAC TP TC 004 approved; Design refer to BS EN/EN60335-1(by request)
- ISOLATION LEVEL
- Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP, Secondary-Earth:1xMOPP
- WITHSTAND VOLTAGE
- I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted emission BS EN/EN55011 (CISPR11) Class B Radiated emission BS EN/EN55011 (CISPR11) Class B Harmonic current BS EN/EN61000-3-2 Class A Voltage flicker BS EN/EN61000-3-3 - EMC IMMUNITYNote 10
-
BS EN/EN55035, BS EN/EN60601-1-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 4, 15KV air; Level 4, 8KV contact RF field susceptibility BS EN/EN61000-4-3 Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) EFT bursts BS EN/EN61000-4-4 Level 3, 2KV Surge susceptibility BS EN/EN61000-4-5 Level 4, 4KV/Line-FG; 2KV/Line-Line Conducted susceptibility BS EN/EN61000-4-6 Level 3, 10V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m Voltage dip, interruption BS EN/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods
OTHERS
- MTBF
- 2082.3K hrs min. Telcordia SR-332 (Bellcore) ; 234.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION (L*W*H)
- 127*76.2*34.6mm or 5" * 3" *1.36" inch
- PACKING
- 0.33Kg; 36pcs/12.9Kg/0.96CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. The rated power includes 5Vsb @ 0.6A.
- 3. The rated power includes 5Vsb @ 0.8A.
- 4. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 5. Tolerance : includes set up tolerance, line regulation and load regulation.
- 6. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 7. Touch current was measured from primary input to DC output.
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 9. HS1,HS2 & HS3 can not be shorted.
- 10. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Oral irrigator
- Hemodialysis machine
- Medical monitors
- Sleep apnea devices
- Pumps machine
Downloads
Certificates6
Catalogues1
FAQ
Can I use the RPSG-160-12 for 12V industrial control hardware?
Yes, if the equipment requires constant 12V DC and the load stays within 9.1A and 112.2W. It can fit industrial control panels, automation devices, and embedded systems built around a 12V bus.
Is the RPSG-160-12 suitable for 12V medical equipment?
It can be used with 12V medical equipment that needs constant voltage and draws no more than 9.1A or 112.2W. The product is listed as a medical power supply, which can be important for medical-system designs.
Can this model power a 12V HMI, display, or embedded computing assembly?
It can support 12V HMI, display, and embedded assemblies as long as the total requirement does not exceed 9.1A and 112.2W. That gives more current capacity than small 12V board-level supplies for multi-board or peripheral-heavy builds.
Is the RPSG-160-12 designed for outdoor conditions?
The stated operating temperature is -20°C to +70°C, which suits a wide range of indoor equipment environments. No IP rating is provided, so it should be treated as a power supply for protected indoor enclosures rather than exposed outdoor use.
How does the RPSG-160-12 compare with the other RPSG-160 models?
The RPSG-160 family includes RPSG-160-5 at 103W and 5V 20A, RPSG-160-12 at 112.2W and 12V 9.1A, RPSG-160-15 at 112.5W and 15V 7.3A, RPSG-160-24 at 113.4W and 24V 4.6A, and RPSG-160-48 at 113.4W and 48V 2.3A. The core difference is the output voltage and current available from each version.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other RPSG-160 Models
4 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well RPSG-160-5 Green Power Supply 155W 5V 20A - Medical Power Supply | 103W | 5V | 20A | View |
| Mean Well RPSG-160-48 Green Power Supply 161W 48V 2.3A - Medical Power Supply | 113.4W | 48V | 2.3A | View |
| Mean Well RPSG-160-24 Green Power Supply 161W 24V 4.6A - Medical Power Supply | 113.4W | 24V | 4.6A | View |
| Mean Well RPSG-160-15 Green Power Supply 159.5W 15V 7.3A - Medical Power Supply | 112.5W | 15V | 7.3A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.