Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
DCWN06W8-05 is the ±5V output model of this series: rated power 6W, typical efficiency 80%.
SCWN06W8 and DCWN06W8 series are 6W isolated and regulated module type DC-DC converter with DIP24 package. It features international standard pins, a high efficiency up to 86%, wide working temperature range -40~+95℃, 3KVdc I/P-O/P isolation voltage, Compliance to BS EN/EN55032 radiated Class B without additional components, continuous-mode short circuit protection, 8:1(9~75V) ultra-wide input range, and various output voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all kinds of systems, such as industrial control, telecommunication field, distributed power architecture, and so on.
Features
- DIP24 package with industry standard pinout
- 8:1(9~75Vdc) ultra-wide input range
- Operating temperature range -40 ~ +95℃
- No minimum load required
- Comply to BS EN/EN55032 radiated Class B without additional components
- High efficiency up to 86%
- Protections: Short circuit (Continuous) / Overload / Over voltage / UVLO
- Remote ON/OFF control (Optional)
- 3KVdc I/O isolation
- 3 years warranty
Specifications
MODEL SELECTION TABLE
- INPUT VOLTAGE (RANGE)
- Nominal 12V, 24V,36V,48V,72V (9 ~ 75V)
- INPUT CURRENT NO LOAD
- 7mA
- INPUT CURRENT FULL LOAD
- 130mA
- OUTPUT VOLTAGE
- ±5V
- OUTPUT CURRENT
- ±500mA
- EFFICIENCY (TYP.)
- 80%
- CAPACITOR LOAD (MAX.)* For each output
- *600μF
INPUT
- VOLTAGE RANGE
- 9~75Vdc
- SURGE VOLTAGE (100ms max.)
- 100Vdc
- FILTER
- Pi type
- PROTECTION (Typ.)
- 2A Fast-Acting Type
OUTPUT
- VOLTAGE ACCURACY
- ±2% for 3.3Vo, ±1.5% for others
- RATED POWER
- 6W
- RIPPLE & NOISENote.2
- 100mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- Single output models:±0.5% ; Dual output models:±1.0%
- CROSS DEGUIATION
- ±5% @ 25%~100% Load only for dual output
- SWITCHING FREQUENCY (Typ.)
- 300KHz
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
- OVERLOAD
- 110 ~ 230% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- Protection type : Clamp by zener diode
- UNDER VOLTAGE LOCKOUT (Typ.) Start-up voltage
- 8.8Vdc
- UNDER VOLTAGE LOCKOUT (Typ.) Shutdown voltage
- 8Vdc
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +95℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +115℃ max.
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +100℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05% / ℃ max. (0 ~ 85℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note.5)
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVdc
- ISOLATION RESISTANCE
- I/P-O/P:1000M Ohms / 500Vdc / 25℃/ 70% RH
- ISOLATION CAPACITANCE (Typ.)
- 1000pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A without additional components Class B with additional components Radiated BS EN/EN55032 Class B without additional components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 2, ±8KV air, ±4KV contact Radiated Susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT/Bursts BS EN/EN61000-4-4 Level 2, 0.5KV Surge BS EN/EN61000-4-5 Level 2, 1KV Line-Line Conducted BS EN/EN61000-4-6 Level 2, 3V(e.m.f.)
OTHERS
- MTBF (Typ.)
- 2500Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 31.8*20.3*10.2mm (1.25*0.8*0.4 inch)
- CASE MATERIAL
- Non-Conductive black plastic (UL 94V-0 rated)
- PACKING
- 12.5g ; 10pcs/per tube, 600pcs/60 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input (48Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 0% to 100% rated load.
- 5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Telecom/datacom system
- Wireless network
- Industrial control facility
- Instrument
- Analyzer
- Detector
- Data switch
Downloads
FAQ
What applications is the Mean Well DCWN06W8-05 suited for?
This model is a 6W isolated DC-DC converter designed for systems that need a regulated ±5V output from a very wide DC input range. It is a practical fit for industrial, control, telecom, and mobile power environments where input voltage can vary significantly between 9V and 75V DC. Its compact DIP package also makes it suitable where board space is limited.
What input voltage range does the DCWN06W8-05 support?
The DCWN06W8-05 has an 8:1 ultra-wide input range of 9V to 75V DC. Mean Well lists nominal input points of 12V, 24V, 36V, 48V, and 72V within that range. It also includes under-voltage lockout, with startup at 8.8V DC and shutdown at 8V DC.
What output does this DC-DC converter provide?
This version provides a ±5V DC output at up to ±500mA per output, within the series' 6W rating. It is intended for applications that require a dual-output supply rather than a single positive rail.
Is the DCWN06W8-05 suitable for harsh temperature environments?
Yes, this model is specified for operation from -40°C to +95°C. That wide temperature range makes it suitable for demanding indoor equipment and many industrial environments, provided the application follows the product's derating guidance. Buyers needing extended environmental tolerance will usually view this as a stronger option than basic commercial-grade converters.
What protection and isolation features does the DCWN06W8-05 include?
The DCWN06W8-05 includes continuous short-circuit protection with automatic recovery, overload protection, over-voltage protection, and under-voltage lockout. It also provides 3KV DC input-to-output isolation. These features help support use in systems where input instability and fault protection are important selection factors.
How does the DCWN06W8-05 differ from narrower-input DC-DC converters?
A key difference is its 8:1 input range, which lets one model cover a much broader span of DC source voltages than converters designed for a narrow nominal input. This can simplify product selection in fleets or equipment platforms that may use different DC buses. It also offers 80% typical efficiency and Class B radiated compliance to EN55032 without additional components.
What compliance and warranty details are provided for this model?
Mean Well specifies EAC TP TC 020/2011 approval for this converter, along with BS EN/EN55032 emission and BS EN/EN61000-4 immunity testing. The spec sheet does not state a warranty period. For buyers comparing industrial power modules, those details can be useful when evaluating compliance needs.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other DCWN06 Models
11 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.