Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RSD-60G-12 is the 12V output model of this series: rated current 5A, rated power 60W, typical efficiency 92%.
RSD-60 is a 60W enclosed type DC-DC reliable railway converter. This series is compliant with BS EN/EN50155/ IEC60571 railway standard, constituting three types of models with 4:1 wide but different input ranges 9~36V/18~72V/40~160V, suitable for railway and all kinds of transportation systems exploiting the frequently used standard input voltages such as 12V, 24V, 36V, 48V, 72V, 96V and 110V. Various output voltages, 3.3V, 5V, 12V and 24V are available for selection. This series has the capability of working under -40~+70℃, low ripple and noise, supreme EMC characteristics, 4KVDC I/P-OP, low enclosure profile 25mm and an interior with semi-potted silicone. It does not only well fits the in-car systems or the facilities by rails for railway, trams and buses but also can be used in the harsh environment with high vibration, high dust, extremely low or high temperature, etc.
Features
- Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
- Ultra compact and 1U low profile(25mm)
- 4:1 wide input range
- No minimum load required
- Protections: Short circuit / Overload / Over voltage / Input reverse polarity
- 4000VDC I/O isolation (Reinforced isolation)
- Half encapsulated , cooling by free air convection
- -40~+70℃ wide working temperature
- Built-in constant current limiting circuit
- LED indicator for power on
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 5A
- CURRENT RANGE
- 0 ~ 5A
- RATED POWER
- 60W
- RIPPLE & NOISE (max.)Note.2
- 50mVp-p
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±0.3%
- SETUP, RISE TIME
- 100ms, 60ms at full load
- HOLD UP TIME (Typ.)
- Please refer to page 5 Hold up Time( Load de-rating curve )
INPUT
- VOLTAGE RANGE CONTINUOUS
- 9 ~ 36VDC
- EFFICIENCY (Typ.)
- 92%
- DC CURRENT (Typ.)
- 3A/24VDC
- INRUSH CURRENT (Typ.)
- 20A/24VDC
- INTERRUPTION OF VOLTAGE SUPPLY
- EN50155:2021-Comply with S1 level
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 13.8 ~ 16.2V Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate)
- WORKING HUMIDITY
- 5 ~ 95% RH non-condensing
- STORAGE TEMP.
- -40 ~ +85℃
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
- OPERATING ALTITUDE
- 5000 meters
SAFETY & EMC
- SAFETY STANDARDS
- IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A Radiated BS EN/EN55032 Class B Harmonic Current BS EN/EN61000-3-2 ----- Voltage Flicker BS EN/EN61000-3-3 -----; BS EN/EN55035 - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, ±8KV air; Level 3, ±6KV contact Radiated Field BS EN/EN61000-4-3 Level X, 20V/m EFT / Burst BS EN/EN61000-4-4 Level 3, 2KV at power Surge BS EN/EN61000-4-5 Level 3,1KV Line-Line, Level 3, 2KV Line-Earth Conducted BS EN/EN61000-4-6 Level 3 - RAILWAY STANDARD
- Compliance to BS EN/EN45545-2 for fire protection ; BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC
OTHERS
- MTBF
- 2738.8K hrs min. Telcordia SR-332 (Bellcore) ; 593.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 128*60*25mm (L*W*H)
- PACKING
- 0.29Kg; 48pcs/14.9Kg/0.75CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Strongly recommended that external output capacitance should not exceed 5000uF.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Bus, tram, metro or railway system
- Highly vibrating, highly dusty, extremely low or high temperature harsh environment
- Wireless network
- Telecom or datacom system
- Industry control system
Downloads
Certificates6
Test reports1
FAQ
Can I use the RSD-60G-12 to power a 12V embedded controller from a vehicle or battery system?
Yes. It delivers a constant 12V output at up to 5A with 60W total power, and the listed input range is 9-36VDC. That makes it a fit for compact 12V electronics that need regulated output within those limits.
Is the RSD-60G-12 suitable for a small 12V industrial sensor or I/O module group?
It can support small 12V industrial loads when the combined demand stays within 5A and 60W. Because it is a constant-voltage model, it is intended for equipment that expects a regulated 12V supply.
Can this model be used in compact automation panels where space is limited?
Yes. The housing is 128.0 × 60.0 × 25.0 mm and the unit weighs 0.29 kg, so it is sized for smaller enclosures. It is still limited to 12V output, 5A current, and 60W total power.
Would the RSD-60G-12 work in mobile or vibration-prone embedded equipment?
It is specified to withstand 5G vibration, which is useful in moving or mechanically stressed equipment. It operates from -40°C to +55°C at full load, and up to +70°C at 60% load by free air convection or at full load with an external base plate.
Is the RSD-60G-12 appropriate for outdoor use?
The temperature spec is -40°C to +70°C (full load to +55°C, derating above that unless base-plate mounted), which supports demanding ambient conditions. No IP rating is listed in the provided specs, so exposed outdoor use should be treated as requiring a protective enclosure.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other RSD-60G Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well RSD-60G-5 DC-DC Converter - 60W - 9~36V in 5V out 12A | 60W | 5V | 12A | IP20 | View |
| Mean Well RSD-60G-24 DC-DC Converter - 60W - 9~36V in 24V out 2.5A | 60W | 24V | 2.5A | IP20 | View |
| Mean Well RSD-60G-3.3 DC-DC Converter - 39.6W - 9~36V in 3.3V out 12A | 39.6W | 3.3V | 12A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.