💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well TKA30B-B DC-DC Converter - 25W - 18~36V in ±12V out

SKU TKA30B-B
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

TKA30B-B is the +5V / ±12V output model of this series: rated power 25W, typical efficiency 82%.

Features

  • 2:1 wide input range
  • 4:1 wide input range(option)
  • 1500VDC I/O isolation
  • Built-in EMI filter
  • Remote ON-OFF control
  • Protections: Short circuit / Overload
  • Cooling by free air convection
  • Six-sided shield metal case
  • Epoxy encapsulated
  • 100% burn-in test
  • Approvals: FCC / EAC / CE / UKCA
  • 2 years warranty

Specifications

TKA30B-BSpecifications from the official datasheet (2024-08-02 edition)

OUTPUT

DC VOLTAGE
+5V / ±12V
CURRENT RANGE
700 ~ 3500mA / ±62 ~ ±310mA
RATED POWER
25W
RIPPLE & NOISE (max.)Note.2
100mVp-p
LINE REGULATIONNote.3
±1.0%
LOAD REGULATIONNote.4
+5V: ±2.0%, ±V1: ±5.0%
VOLTAGE ACCURACY
+5V: ±2.0%, ±V1: ±5.0%
SWITCHING FREQUENCY
100KHz min.

INPUT

VOLTAGE RANGE
18~36VDC
EFFICIENCY (Typ.)
82%
DC CURRENT Full load
1.27A
DC CURRENT No load
18mA
FILTER
Pi network
PROTECTION
Fuse recommended

PROTECTION (Note. 5)

OVERLOAD
110 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
SHORT CIRCUIT
All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.
-40 ~ +85℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +105℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03% / ℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
EAC TP TC 020/2011 approved
WITHSTAND VOLTAGE
I/P-O/P:1.5KVDC
ISOLATION RESISTANCE
I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 Class B, FCC part 15 Class B , EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020

OTHERS

REMOTE CONTROL
Power on: R.C ~-Vin > 4.5~5.5VDC or open, Power off: R.C~ -Vin <0.8VDC or short
MTBF
100Khrs min. MIL-HDBK-217F(25℃)
DIMENSION
50.8*50.8*21.0mm or 2"*2"*0.82" inch (L*W*H)
PACKING
110g ; 5pcs/per tube, 140pcs/28 tube/per carton
Test conditions and notes5
  1. 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
  2. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
  3. 3.Line regulation is measured from low line to high line at rated load.
  4. 4.Load regulation is measured from 20% to 100% rated load.
  5. 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.

Technical drawings

TKA30B-B Mechanical Specification
Mechanical Specification
TKA30B-B Packing
Packing

Downloads

FAQ

Can I use the TKA30B-B in a 24V-class industrial AC system that needs 12V output for control electronics?

Yes, the published input range is 18-36VAC, which fits 24V-class AC systems within that range. The output is listed as 12V constant voltage with a 25W power rating.

Is the TKA30B-B suitable for embedded or automation devices that require 12V power from an 18-36VAC source?

It is designed for 18-36VAC input and 12V output operation in constant-voltage mode. The product is rated at 25W, so the connected embedded or automation load needs to stay within that published power limit.

Can this converter be used for 12V interface or signal-conditioning hardware in industrial equipment?

It can be considered where the available source is 18-36VAC and the downstream hardware uses 12V constant voltage. The provided specifications list 25W power and a published output current of 310A.

Would the TKA30B-B make sense for compact 12V power conversion inside automation assemblies?

Its listed dimensions are 50.8 x 50.8 x 21.0 mm and the weight is 0.11 kg, which supports use in compact assemblies. The electrical spec is 18-36VAC input with 12V constant-voltage output at 25W.

Is the TKA30B-B rated for outdoor environments or only temperature extremes?

The published operating temperature range is -40°C to +85°C, so the unit is specified for a wide temperature span. No IP rating is provided in the specs, so outdoor or water-exposed suitability is not established by the listed data.

How does TKA30B-B differ from TKA30B-C?

The provided sibling specs show both models at 25W with 18-36VAC input, 12V output, and the same 50.8 x 50.8 x 21.0 mm dimensions. The published difference is output current: TKA30B-B is listed at 310A, while TKA30B-C is listed at 250A.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8442875248939, "variants" :[{ "context":"default", "variant_id": 45713161290027, "sku":"TKA30B-B", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well TKA30B-B DC-DC Converter - 25W - 18~36V in ±12V out
Mean Well

Mean Well TKA30B-B DC-DC Converter - 25W - 18~36V in ±12V out

TKA30B-B is the +5V / ±12V output model of this series: rated power 25W, typical efficiency 82%.

Features

  • 2:1 wide input range
  • 4:1 wide input range(option)
  • 1500VDC I/O isolation
  • Built-in EMI filter
  • Remote ON-OFF control
  • Protections: Short circuit / Overload
  • Cooling by free air convection
  • Six-sided shield metal case
  • Epoxy encapsulated
  • 100% burn-in test
  • Approvals: FCC / EAC / CE / UKCA
  • 2 years warranty
View product