Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
TKA30B-C is the +5V / ±15V output model of this series: rated power 25W, typical efficiency 82%.
Features
- 2:1 wide input range
- 4:1 wide input range(option)
- 1500VDC I/O isolation
- Built-in EMI filter
- Remote ON-OFF control
- Protections: Short circuit / Overload
- Cooling by free air convection
- Six-sided shield metal case
- Epoxy encapsulated
- 100% burn-in test
- Approvals: FCC / EAC / CE / UKCA
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- +5V / ±15V
- CURRENT RANGE
- 700 ~ 3500mA / ±50 ~ ±250mA
- RATED POWER
- 25W
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p
- LINE REGULATIONNote.3
- ±1.0%
- LOAD REGULATIONNote.4
- +5V: ±2.0%, ±V1: ±5.0%
- VOLTAGE ACCURACY
- +5V: ±2.0%, ±V1: ±5.0%
- SWITCHING FREQUENCY
- 100KHz min.
INPUT
- VOLTAGE RANGE
- A: 9 ~ 18VDC B: 18~36VDC C: 36~72VDC
- EFFICIENCY (Typ.)
- 82%
- DC CURRENT Full load
- A: 2.61A B: 1.27A C: 0.64A
- DC CURRENT No load
- A: 40mA B: 18mA C: 10mA
- FILTER
- Pi network
- PROTECTION
- Fuse recommended
PROTECTION (Note. 5)
- OVERLOAD
- 110 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +105℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 Class B, FCC part 15 Class B , EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020
OTHERS
- REMOTE CONTROL
- Power on: R.C ~-Vin > 4.5~5.5VDC or open, Power off: R.C~ -Vin <0.8VDC or short
- MTBF
- 100Khrs min. MIL-HDBK-217F(25℃)
- DIMENSION
- 50.8*50.8*21.0mm or 2"*2"*0.82" inch (L*W*H)
- PACKING
- 110g ; 5pcs/per tube, 140pcs/28 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 20% to 100% rated load.
- 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
Technical drawings
Downloads
FAQ
Can the TKA30B-C be used in industrial control gear that has 18-36VAC available and needs 12V output?
Yes, its published input range is 18-36VAC and its output is listed as 12V constant voltage. The unit is rated at 25W for loads that match those specifications.
Is this model appropriate for powering 12V embedded electronics in automation systems?
It is intended for 12V constant-voltage output from an 18-36VAC source. With a published power rating of 25W, it suits embedded electronics that stay within that power envelope.
Can I use the TKA30B-C for 12V monitoring or control modules in a 24V-class AC environment?
It can fit that type of application when the source falls within 18-36VAC and the module requires 12V output. The provided specs list 25W power and a published output current of 250A.
Does the TKA30B-C fit space-constrained industrial or embedded builds?
The product is listed at 50.8 x 50.8 x 21.0 mm and 0.11 kg, so it is compact in physical size. Electrically, it is specified for 18-36VAC input and 12V constant-voltage output.
Is the TKA30B-C suitable for outdoor exposure or just wide-temperature operation?
The published operating range is -40°C to +85°C, which supports use across broad temperature conditions. However, there is no IP rating in the provided specs, so the data does not confirm outdoor or wet-location suitability.
What is the spec difference between TKA30B-C and TKA30B-B?
According to the provided sibling data, both are listed as 25W converters with 18-36VAC input, 12V output, and identical dimensions of 50.8 x 50.8 x 21.0 mm. The published distinction is output current: TKA30B-C is listed at 250A and TKA30B-B is listed at 310A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other TKA30 Models
5 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well TKA30C-C DC-DC Converter - 25W - 36~72V in ±12V out | 25W | 12V | 250 Milliampere | IP20 | View |
| Mean Well TKA30C-B DC-DC Converter - 25W - 36~72V in ±12V out | 25W | 12V | 310 Milliampere | IP20 | View |
| Mean Well TKA30B-B DC-DC Converter - 25W - 18~36V in ±12V out | 25W | 12V | 310 Milliampere | IP20 | View |
| Mean Well TKA30A-C DC-DC Converter - 25W - 9~18V in 5V out | 25W | 5V | 3.5A | IP20 | View |
| Mean Well TKA30A-B DC-DC Converter - 25W - 9~18V in 5V out | 25W | 5V | 3.5A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.