Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
DCW12A-12 is the ±12V output model of this series: rated power 12W, typical efficiency 84%.
Features
- 2:1 wide input range
- 1500VDC I/O isolation
- Built-in remote ON/OFF control
- Built-in EMI filter
- Protections: Short circuit / Overload
- Cooling by free air convection
- Five-sided shield metal case
- 100% full load burn-in test
- Low cost / High reliability
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- ±12V
- CURRENT RANGE
- ±100~ ±500mA
- RATED POWER
- 12W
- RIPPLE & NOISE (max.)Note.2
- 60mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±0.5%
- VOLTAGE ACCURACY
- ±2.0%
- SWITCHING FREQUENCY
- 400KHz min.
- EXTERNAL CAPACITANCE LOAD (max.)
- 100uF
INPUT
- VOLTAGE RANGE
- 9 ~ 18VDC
- EFFICIENCY (Typ.)
- 84%
- DC CURRENT Full load
- 1245mA
- DC CURRENT No load
- 70mA
- FILTER
- Pi network
- PROTECTION
- Fuse recommended
PROTECTION
- OVERLOADNote.5
- 110 ~ 180% rated output load Protection type : Hiccup mode, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- All output equipped with over current protection Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +71℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +105℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.05% / ℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION CAPACITANCE
- 2200pF max.
- EMC EMISSION
- Compliance to BS EN/EN55032 Class A, FCC part 15 Class A , EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020
OTHERS
- REMOTE CONTROL
- Power ON: R.C. ~ -Vin > 4VDC or open ; Power OFF: R.C. ~ -Vin < 1VDC or short
- MTBF
- 600Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 31.8*20.3*12.2mm (L*W*H) or 1.25"*0.80"*0.48" inch (L*W*H)
- PACKING
- 17.5g ; 15 pcs/per tube, 750 pcs/ 50 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 20% to 100% rated load.
- 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
Technical drawings
Downloads
Datasheet1
Certificates3
FAQ
What is the Mean Well DCW12A-12 used for?
The DCW12A-12 is a 12W isolated DC-DC converter for applications that need a 9 to 18V DC input and a ±12V DC output. It is suited to compact industrial and embedded systems where regulated dual-output DC power and input-to-output isolation are required.
What are the key electrical ratings of the DCW12A-12?
This model is rated for 12W output power, with a 9 to 18V DC input range and ±12V output. The rated output current is 500 mA, and voltage set point accuracy is specified at ±2.0%.
Does the DCW12A-12 provide input-to-output isolation?
Yes, the DCW12A-12 provides 1500VDC input-to-output isolation. Its specification lists I/P-O/P withstand voltage at 1.5KVDC, along with isolation resistance of 100M Ohms at 500VDC.
What protection features are included in the DCW12A-12?
This converter includes short circuit and overload protection. Overload protection is specified at 110% to 180% with auto-recovery, and short circuit protection uses hiccup mode that recovers automatically after the fault is removed.
Can the DCW12A-12 be used in demanding temperature environments?
It is designed for a wide operating temperature range of -40 to +71°C, subject to the output derating curve. Storage temperature is specified from -40 to +105°C, which supports use in demanding industrial environments.
How compact is the Mean Well DCW12A-12?
The DCW12A-12 has compact dimensions of 31.8 x 20.3 x 12.2 mm and weighs 17.5 g. It also uses a five-sided shield metal case, which helps combine small size with mechanical protection and shielding.
What compliance and reliability features does the DCW12A-12 offer?
The unit includes a built-in EMI filter, 100% full load burn-in testing, and a two-year warranty. EMC compliance is listed to EN55032 Class A, EN61000-4-2,3,4,5,6,8, and FCC Part 15 Class A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other DCW12 Models
9 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well DCW12A-12 DC-DC Converter - 12W - 9~18V in ±12V out 500mA | 12W | 12V | 0.5A | Indoor | View |
| Mean Well DCW12C-15 DC-DC Converter - 12W - 36~72V in ±15V out 400mA | 12W | 15V | 400 Milliampere | IP20 | View |
| Mean Well DCW12C-12 DC-DC Converter - 12W - 36~72V in ±12V out 500mA | 12W | 12V | 500 Milliampere | IP20 | View |
| Mean Well DCW12C-05 DC-DC Converter - 12W - 36~72V in ±5V out 1.2A | 12W | 5V | 1.2A | IP20 | View |
| Mean Well DCW12B-15 DC-DC Converter - 12W - 18~36V in ±15V out 400mA | 12W | 15V | 400 Milliampere | IP20 | View |
| Mean Well DCW12B-12 DC-DC Converter - 12W - 18~36V in ±12V out 500mA | 12W | 12V | 500 Milliampere | IP20 | View |
| Mean Well DCW12B-05 DC-DC Converter - 12W - 18~36V in ±5V out 1.2A | 12W | 5V | 1.2A | IP20 | View |
| Mean Well DCW12A-15 DC-DC Converter - 12W - 9~18V in ±15V out 400mA | 12W | 15V | 400 Milliampere | IP20 | View |
| Mean Well DCW12A-05 DC-DC Converter - 12W - 9~18V in ±5V out 1.2A | 12W | 5V | 1.2A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.