Overview
DDRH-15-12DR is the 12V output model of this series: rated power 5Vo: 10W 12Vo ~ 24Vo: 15W, typical efficiency 79%.
DDRH-15 series is a 150 ~ 1500Vdc high reliable ultra-high input DC-DC converter which can supply stable working voltage for the load. Main features are as following: compact size, -40~+80℃ wide range operating temperature, 4KVac high isolation voltage, operation at 5000m altitude, low ripple & noise, complete protections and so on. Futhermore, this series also has DIN Rail type, it is suitable to be mounted on TS-35/7.5 or TS-35/15 rails. DDRH-15 is designed to meet UL1741 and IEC62109-1 standard. It is suitable for industrial automation, surveillance, telecommunication and can be widely deployed in the applications of new energy generation such as solar power, and windmill power generation, for instances, photovoltaic power systems, high voltage inverting , DC bus centralized application , ESS, charging pile, railway and so forth.
Features
- 150~1500Vdc 10:1 ultra-wide input range
- 4KVac I/O high isolation(Reinforced isolation)
- Protections: Short circuit / Overload / Over voltage / DC input under voltage / DC input reverse Polarity
- Fanless design, fully encapsulated, cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15 (DR-Type)
- -40~+80℃ ultra-wide operating temperature (>+50℃ derating)
- Operating altitude up to 5000 meters
- 3 years warranty
Specifications
MODEL SELECTION TABLE
- INPUT VOLTAGE (RANGE)
- Nominal 800Vdc (150~1500Vdc)
- INPUT CURRENT NO LOAD
- 0.2mA
- INPUT CURRENT FULL LOAD
- 30mA
- OUTPUT VOLTAGE
- 12V
- OUTPUT CURRENT
- 1.25A
- EFFICIENCY (Typ.)
- 79%
- CAPACITOR LOAD (MAX.)
- 1250μF
INPUT
- VOLTAGE RANGE
- 150 ~ 1500Vdc
- FILTER
- Internal capacitor
- EXTERNAL INPUT FUSE
- 4A/1500Vdc, required (Please refer to page 6 for more details)
- INRUSH CURRENT (Typ.)
- Cold start 150A max. @ Vin=800Vdc
OUTPUT
- VOLTAGE ACCURACY
- ±2.0%
- RATED POWER
- 5Vo: 10W 12Vo ~ 24Vo: 15W
- RIPPLE & NOISENote.2
- 5 ~ 15Vo: 100mVp-p 24Vo: 150mVp-p
- LINE REGULATION
- ±1%
- LOAD REGULATION
- ±1% (10% Load to Full Load)
- SWITCHING FREQUENCY (Typ.)
- 25 ~ 75.6KHz
- HOLD UP TIME
- 16ms min. @Vin=800Vdc
- SETUP TIME
- 1s max. @150~1500Vdc
PROTECTION
- SHORT CIRCUIT
- Protection type : Hiccup mode, continuous, automatic recovery
- OVERLOAD
- 110 ~ 300% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- Hiccup mode, recovers automatically after fault condition is removed
- DC INPUT REVERSE POLARITY
- By internal Bridge Diode, no damage, recovers automatically after fault condition removed
- DC INPUT UNDER VOLTAGE LOCKOUT Start-up voltage
- 147Vdc
- DC INPUT UNDER VOLTAGE LOCKOUT Shutdown voltage
- 137Vdc
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +80℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.02% / ℃ (0 ~ 50℃)
- VIBRATION
- Component: 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting clip: Compliance to IEC60068-2-6
- OPERATING ALTITUDENote.3
- 5000 meters
- OVER VOLTAGE CATEGORY
- Ⅱ ; According to EN62109-1; altitude up to 5000 meters
SAFETY & EMC
- SAFETY STANDARDS
- UL1741 , CSA C22.2 No.107.1-16 , IEC62109-1 (LVD), EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:4KVac
- ISOLATION RESISTANCE
- I/P-O/P, 100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A (with external components) Radiated BS EN/EN55032 Class A (with external components) - EMC IMMUNITY
-
BS EN/EN55035
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact, criteria A Radiated Susceptibility BS EN/EN61000-4-3 Level 3, 10V, criteria A EFT/Bursts BS EN/EN61000-4-4 Level 2, 0.5KV, criteria A Surge BS EN/EN61000-4-5 Level 4, 2KV/Vin+ ~ Vin-, criteria A Conducted BS EN/EN61000-4-6 Level 3, 10V, criteria A
OTHERS
- MTBF
- 388Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- P Type: 76.2*50.8*25mm, ST Type: 122.3*57.3*32mm, DR Type: 122.3*57.3*43.5mm
- CASE MATERIAL
- Non-conductive black plastic (UL 94V-0 rated)
- POTTING MATERIAL
- UL 94V-0
- PIN MATERIAL
- Base: copper, Plating: Matte Tin
- PACKING
- P Type : 170g ; 6pcs/Tray, 18pcs/per carton ST Type : 210g ; 6pcs/Tray, 18pcs/per carton DR Type : 215g ; 6pcs/Tray, 18pcs/per carton
Test conditions and notes4
- 1. All parameters NOT specially mentioned are measured at 800Vdc input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
- 3. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Photovoltaic power generation
- Renewable Energy System
- High voltage frequency conversion
- Industrial control system
- Semiconductor fabrication equipment
- Electro-mechanical apparatus
- DC bus centralized application
- Energy storage system(ESS)
- Charging pile
- Third rail
Downloads
Datasheet1
FAQ
Can the DDRH-15-12DR power 12V sensors or transmitters from a high-voltage DC bus in a process control system?
Yes. The DDRH-15-12DR delivers 12V at 1.25A (15W) from a 150–1500VDC input, making it appropriate for supplying 12V loop-powered sensors, 4-20mA transmitters, or small instruments in process control panels connected to high-voltage DC buses.
Is the DDRH-15-12DR suitable for providing isolated 12V power to intrinsically safe barriers or Zener barriers?
The DDRH-15-12DR provides 15W at 12V/1.25A from a 150–1500VDC input, mounts on a DIN rail, and has 4KVac input-to-output isolation. However, the sheet lists no intrinsic-safety or hazardous-location approval, so verify the specific IS application requirements before using it with IS barriers.
Can I use the DDRH-15-12DR in a renewable energy cabinet where the input bus is 400–800VDC?
Yes. The 10:1 ultra-wide input range of 150–1500VDC makes the DDRH-15-12DR compatible with 400–800VDC input from solar or wind energy DC buses, supplying a regulated 12V/1.25A output for instrumentation or control circuits.
What is the operating temperature range of the DDRH-15-12DR?
The DDRH-15-12DR operates from -40°C to +80°C with a fanless design, with load derating at high ambient temperatures per the derating curve. This wide temperature range makes it suitable for cold-climate deployments and high-ambient industrial enclosures; outdoor equipment needs a protective enclosure, as no IP rating is specified.
How does the DDRH-15-12DR differ from the DDRH-15-12P and DDRH-15-12ST models?
All three deliver 15W at 12V/1.25A from 150–1500VDC input. The DDRH-15-12DR is DIN rail-mount (122.3 × 57.3 × 43.5 mm, 0.215 kg), while the DDRH-15-12P is PCB-mount and the DDRH-15-12ST uses screw terminals. Select the variant that matches your panel's mounting and wiring requirements.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other DDRH-15 Models
11 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.