HLN-60H-15B is the 15V output model of this series: rated current 4A, rated power 60W, typical efficiency 87%.
Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- Fully isolated plastic case with IP64 level
- Class 2 power unit
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Suitable for LED lighting, Industrial Lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- Suitable for dry / damp locations or outdoor application
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- CONSTANT CURRENT REGIONNote.4
- 9 ~ 15V
- RATED CURRENT
- 4A
- RATED POWER
- 60W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGENote.6
- 13.5 ~ 17V
- CURRENT ADJ. RANGE
- 2.4 ~ 4A
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.5%
- SETUP, RISE TIMENote.7
- 500ms, 80ms at full load 230VAC / 115VAC
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 87%
- AC CURRENT (Typ.)
- 0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 18 ~ 24V
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- Ul8750, CSA C22.2 No. 250.0-08, BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, IP64, EAC TP TC 004 approved ; design refer to UL60950-1, BS EN/EN60335-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), EAC TP TC 020
OTHERS
- MTBF
- 3400.0K hrs min. Telcordia SR-332(Bellcore) ; 347.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 161*61.5*35mm (L*W*H)
- PACKING
- 0.46Kg;32pcs/15.7Kg/1.10CUFT
Certifications & ratings
- Marked features
- FC
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. A type only.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Downloads
FAQ
Can I use the HLN-60H-15B for dimmable LED signage at 15V?
Yes, if the sign uses a 15V LED load or a constant-current LED load operating within 9-15V at up to 4A. This driver is rated 60W at 15V and suits signage applications. The connected load still needs to match the driver's 15V output or constant-current range.
Is the HLN-60H-15B suitable for dimmable accent lighting in a 15V system?
It can be suitable when the fixture is designed for 15V or for constant-current operation from 9-15V at up to 4A. The available output power is 60W, so the total lighting load needs to remain within that rating. It works in constant voltage or constant current mode, so match the fixture to one of those.
How do I estimate LED strip length for the HLN-60H-15B?
Use the driver's power limit: 60W divided by the strip's rated watts per meter equals the estimated maximum length. That estimate applies if the strip is a 15V constant-voltage product or a constant-current load within the 9-15V range at up to 4A. Check your strip rated power per meter before sizing.
Can this driver be used outdoors for sign or lighting projects?
It is intended for conditions where IP64 protection is appropriate, and it operates from -40°C to +50°C. That supports dusty areas and splashing water exposure, but not submersion. Use it where the environment matches an IP64-rated driver.
How does the HLN-60H-15B compare with the HLN-60H-15A and related HLN models?
The HLN-60H-15B and HLN-60H-15A share the same 60W, 15V, 4A electrical rating; the B type adds 3-in-1 dimming, the A type internal voltage and current adjustment. Other 60H outputs on this sheet are 20V 3A, 24V 2.5A, 30V 2A, 36V 1.7A, 42V 1.45A, 48V 1.3A, and 54V 1.15A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HLN-60H Models
15 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.