Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLN-60H-30B is the 30V output model of this series: rated current 2A, rated power 60W, typical efficiency 89.5%.
Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- Fully isolated plastic case with IP64 level
- Class 2 power unit
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Suitable for LED lighting, Industrial Lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- Suitable for dry / damp locations or outdoor application
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 30V
- CONSTANT CURRENT REGIONNote.4
- 18 ~ 30V
- RATED CURRENT
- 2A
- RATED POWER
- 60W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGENote.6
- 27 ~ 33V
- CURRENT ADJ. RANGE
- 1.2 ~ 2A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.7
- 500ms, 80ms at full load 230VAC / 115VAC
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 89.5%
- AC CURRENT (Typ.)
- 0.64A / 115VAC 0.32A / 230VAC 0.3A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 55A(twidth=265μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 9 units (circuit breaker of type B) / 16 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 35 ~ 43V
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- Ul8750, CSA C22.2 No. 250.0-08, BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, IP64, EAC TP TC 004 approved ; design refer to UL60950-1, BS EN/EN60335-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), EAC TP TC 020
OTHERS
- MTBF
- 3400.0K hrs min. Telcordia SR-332(Bellcore) ; 347.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 161*61.5*35mm (L*W*H)
- PACKING
- 0.46Kg;32pcs/15.7Kg/1.10CUFT
Certifications & ratings
- Marked features
- FC
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. A type only.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Downloads
FAQ
Can I use the HLN-60H-30B for dimmable 30V signage lighting?
Yes, this dimmable driver can be used for signage lighting when the LED load is designed for constant-current operation at 30V. It provides up to 2A and 60W, and the supported constant-current range is 18-30V.
Is the HLN-60H-30B a fit for dimmable accent or cove lighting?
It can be a fit for dimmable accent or cove lighting if the LED load matches a 30V constant-current driver and stays within 2A and 60W. The fixture should also operate inside the 18-30V CC range.
Can this driver run a 30V LED strip in a lighting display?
It can run a lighting display strip when the strip is a 30V constant-voltage type or a constant-current load compatible with 30V output. Check the strip's rated power per meter and confirm the total load stays within 60W and 2A.
How much LED strip can I use with the HLN-60H-30B?
Use the driver's 60W rating to calculate the maximum length: 60W divided by the strip's rated watts per meter. Check your strip rated power per meter, and make sure the strip suits this 30V, 2A constant voltage + constant current driver (18-30V CC range).
Can the HLN-60H-30B be used in damp or outdoor areas?
Its IP64 rating supports use where dust protection and resistance to splashing water are important, including many damp or outdoor lighting areas. The operating temperature range is -40°C to +50°C, but IP64 is not a submerged-use rating.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HLN-60H Models
15 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.