Mean Well HRPG-1000-24 Power Supply 1008W 24V 42A

built-in active PFCPF > 0.95high efficiency up to 90%no load power consumption <0.5W~0.75W1U low profile
SKU HRPG-1000-24
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

HRPG-1000-24 is the 24V output model of this series: rated current 42A, rated power 1008W, typical efficiency 93%.

HRPG-1000 is a single output enclosed type AC/DC power supply providing 1000 W output power for a wide range of industrial applications. This series operates for 90~264 VAC input voltage and offers models with different rated voltage ranging between 12 and 48 V that can satisfy the demands for all kinds of industrial equipments. Each model is cooled by the built-in fan with speed control, working for the temperature up to 70℃. Moreoever, HRPG-1000 has various built-in functions such as auxiliary power, remote sense and remote on-off control, offering vast design flexibility for industrial application.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 94%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in cooling fan ON-OFF control
  • Current sharing up to 4000W (3+1)
  • Built-in DC OK signal
  • Built-in remote ON-OFF control
  • Standby 5V@0.3A
  • Built-in remote sense function
  • No load power consumption<0.75W (Note.6)
  • 5 years warranty

Specifications

HRPG-1000-24Specifications from the official datasheet (2024-10-30 edition)

OUTPUT

DC VOLTAGE
24V
RATED CURRENT
42A
CURRENT RANGE
0 ~ 42A
RATED POWER
1008W
RIPPLE & NOISE (max.)Note.2
200mVp-p
VOLTAGE ADJ. RANGE
22 ~ 28V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.4
90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
93%
AC CURRENT (Typ.)
8.5A/115VAC 5A/230VAC
INRUSH CURRENT (Typ.)
25A/115VAC 40A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
29 ~ 33V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

CURRENT SHARING
Up to 4000W or (3+1) units. Please refer to the Function Manual.
REMOTE ON-OFF CONTROL
Power ON : short; Power OFF : open. Please refer to the Function Manual.
REMOTE SENSE
Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.
DC-OK SIGNAL
The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V. Please refer to the Function Manual.
5V STANDBY
5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
FAN CONTROL
Fan on/off by NTC(RT50) or 30% load min.

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL62368-1, CAN/CSA C22.2 No. 62368-1 , TUV BS EN/ EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032 (CISPR32)Class B
RadiatedBS EN/EN55032 (CISPR32)Class B
Harmonic CurrentBS EN/EN61000-3-2Class A
Voltage FlickerBS EN/EN61000-3-3
EMC IMMUNITY

BS EN/EN55024, BS EN/EN61000-6-2

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 2, 4KV contact
RadiatedBS EN/EN61000-4-3Level 3
EFT / BurstBS EN/EN61000-4-4Level 3
SurgeBS EN/EN61000-4-5Level 4, 2KV/Line-Line 4KV/Line-Earth
ConductedBS EN/EN61000-4-6Level 3
Magnetic FieldBS EN/EN61000-4-8Level 4
Voltage Dips and InterruptionsBS EN/EN61000-4-11>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

OTHERS

MTBF
286.6K hrs min. Telcordia SR-332 (Bellcore) ; 105.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
218*105*63.5mm (L*W*H)
PACKING
1.53Kg;8pcs/13.3Kg/1.34CUFT
Test conditions and notes8
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
  5. 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  6. 6. No load power consumption<0.75W when RC+ & RC- (CN100 pin3,4) open.
  7. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  8. 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRPG-1000-24 Block Diagram
Block Diagram
HRPG-1000-24 Derating Curve
Derating Curve
HRPG-1000-24 Function Manual
Function Manual
HRPG-1000-24 H R P G - 1 0 0 0 series
H R P G - 1 0 0 0 series
HRPG-1000-24 4.Current Sharing
4.Current Sharing
HRPG-1000-24 Mechanical Specification
Mechanical Specification

Typical applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Aging equipment
  • RF application

Downloads

FAQ

Can I use the HRPG-1000-24 for a 24V PLC, industrial control, or automation cabinet?

Yes, this model is built for constant-voltage 24V systems and can supply up to 42A, with a total output rating of 1008W. That makes it suitable for larger 24V control and automation loads that need high capacity from a single unit.

Is the HRPG-1000-24 a good fit for a centralized 24V power bus in industrial equipment?

It can be, because it provides 1008W at 24V from a single constant-voltage source and accepts 90-264VAC input. The 218.0 x 105.0 x 63.5 mm dimensions also make it easier to place in equipment where high 24V power density matters.

Can this power supply support 24V embedded or machine electronics with sustained higher current demand?

Yes, the HRPG-1000-24 is intended for fixed 24V loads and provides up to 42A. Up to four units can be paralleled with active current sharing for larger embedded, automation, or industrial systems, while a single unit stays within its 1008W rating.

How does the HRPG-1000-24 compare with other 1000-class HRPG models?

The HRPG-1000 family includes HRPG-1000-12 at 960W, 12V, 80A; HRPG-1000-15 at 960W, 15V, 64A; this HRPG-1000-24 at 1008W, 24V, 42A; and HRPG-1000-48 at 1008W, 48V, 21A.

Can the HRPG-1000-24 be used in cold or hot operating areas?

Its specified operating range is -40C to +70C, with output derating at higher ambient temperatures per the derating curve, so it is rated for both low-temperature and elevated-temperature operation. No IP rating is provided in the specs, so the listed data does not confirm outdoor, wet-location, or dust-exposed use.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8343889477931, "variants" :[{ "context":"default", "variant_id": 45321004450091, "sku":"HRPG-1000-24", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRPG-1000-24  Power Supply 1008W 24V 42A
Mean Well

Mean Well HRPG-1000-24 Power Supply 1008W 24V 42A

HRPG-1000-24 is the 24V output model of this series: rated current 42A, rated power 1008W, typical efficiency 93%.

HRPG-1000 is a single output enclosed type AC/DC power supply providing 1000 W output power for a wide range of industrial applications. This series operates for 90~264 VAC input voltage and offers models with different rated voltage ranging between 12 and 48 V that can satisfy the demands for all kinds of industrial equipments. Each model is cooled by the built-in fan with speed control, working for the temperature up to 70℃. Moreoever, HRPG-1000 has various built-in functions such as auxiliary power, remote sense and remote on-off control, offering vast design flexibility for industrial application.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 94%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in cooling fan ON-OFF control
  • Current sharing up to 4000W (3+1)
  • Built-in DC OK signal
  • Built-in remote ON-OFF control
  • Standby 5V@0.3A
  • Built-in remote sense function
  • No load power consumption<0.75W (Note.6)
  • 5 years warranty

Typical applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Aging equipment
  • RF application