Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
MDR-60-12 is the 12V output model of this series: rated current 5A, rated power 60W, typical efficiency 85%.
Features
- Universal AC input/Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Class I, Div 2 Hazardous Locations T4
- LED indicator for power on
- DC OK relay contact
- No load power consumption<0.75W
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 5A
- CURRENT RANGE
- 0 ~ 5A
- RATED POWER
- 60W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- VOLTAGE ADJ. RANGE
- 12 ~ 15V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIMENote.5
- 500ms, 30ms/230VAC 500ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 20ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 85%
- AC CURRENT (Typ.)
- 1.8A/115VAC 1A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 30A/115VAC 60A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 150% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 15.6 ~ 18V Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
- DC OK SIGNAL
- Relay contact rating(max.): 30V/1A resistive
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- Component : 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ; Mounting : Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL508, UL62368-1, TUV BS EN/EN62368-1,Class I, Div. 2 Group A, B, C, D Hazardous Locations T4, EAC TP TC 004, BSMI CNS14336-1, AS/NZS 60950.1 , BIS IS13252(Part1): 2010/IEC 60950-1:2005(except 48V) approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS13438 Class B
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2, 3, 4, 5, 6, 8, 11, BS EN/EN55035, BS EN/EN61000-6-2, BS EN/EN61204-3, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 2355.2K hrs min. Telcordia SR-332 (Bellcore) ; 489.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 40*90*100mm (W*H*D)
- PACKING
- 287g; 42pcs/13.05Kg/0.82CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the MDR-60-12 for a 12V control panel with a higher DC load than the 40W version?
Yes, this model provides 12V DC up to 5A with a 60W rating, so it supports more 12V load than a 40W supply. It is suited to DIN rail control panels that need additional current capacity without changing to a different output voltage.
Is the MDR-60-12 suitable for 12V building automation or industrial control devices in one enclosure?
It can be used for 12V building management and automation loads when the combined demand stays within 60W and 5A. That makes it a practical option for cabinets feeding several 12V devices from one DIN rail supply.
Would the MDR-60-12 work for 12V relays, sensors, and controller accessories in a DIN rail cabinet?
Yes, provided the total 12V DC load does not exceed 5A or 60W. The DIN rail design and compact 40 mm width make it suitable for control cabinets where multiple 12V accessories share one power source.
Is this model appropriate for compact panels even though it has a higher 12V output?
Yes, it uses a compact 40 x 90 x 100 mm (W x H x D) housing that mounts on TS-35/7.5 or TS-35/15 DIN rail. That allows a 60W, 12V supply to fit into narrow DIN rail panel layouts.
Can the MDR-60-12 be used in a control cabinet across a wide temperature range?
Yes, the specified operating range is -20C to +70C, with output derating at higher temperatures per the sheet's derating curve, which supports industrial cabinet use across a broad temperature span. The provided specs do not list a separate exposed-environment protection rating, so enclosure installation is the safer fit.
How does the MDR-60-12 compare with other MDR DIN rail siblings?
Within the MDR-60 series, the MDR-60-12 provides 60W at 12V and 5A. The other models on the same sheet are the MDR-60-5 at 50W and 10A, the MDR-60-24 at 60W and 2.5A, and the MDR-60-48 at 60W and 1.25A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other MDR-60 Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well MDR-60-24 Single Output Industrial Power Supply 60W 24V 2.5A - DIN Rail | 60W | 24V | 2.5A | IP20 | View |
| Mean Well MDR-60-48 Single Output Industrial Power Supply 60W 48V 1.25A - DIN Rail | 60W | 48V | 1.25A | IP20 | View |
| Mean Well MDR-60-5 Single Output Industrial Power Supply 60W 5V 10A - DIN Rail | 50W | 5V | 10A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.