Mean Well RSD-60G-24 DC-DC Converter - 60W - 9~36V in 24V out 2.5A

miniature sizeeconomicalwithstand 5G vibration and 70°C operation
SKU RSD-60G-24
Log in to see price Trade pricing & online ordering for account holders
In stock
|

Overview

RSD-60G-24 is the 24V output model of this series: rated current 2.5A, rated power 60W, typical efficiency 90%.

RSD-60 is a 60W enclosed type DC-DC reliable railway converter. This series is compliant with BS EN/EN50155/ IEC60571 railway standard, constituting three types of models with 4:1 wide but different input ranges 9~36V/18~72V/40~160V, suitable for railway and all kinds of transportation systems exploiting the frequently used standard input voltages such as 12V, 24V, 36V, 48V, 72V, 96V and 110V. Various output voltages, 3.3V, 5V, 12V and 24V are available for selection. This series has the capability of working under -40~+70℃, low ripple and noise, supreme EMC characteristics, 4KVDC I/P-OP, low enclosure profile 25mm and an interior with semi-potted silicone. It does not only well fits the in-car systems or the facilities by rails for railway, trams and buses but also can be used in the harsh environment with high vibration, high dust, extremely low or high temperature, etc.

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Ultra compact and 1U low profile(25mm)
  • 4:1 wide input range
  • No minimum load required
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity
  • 4000VDC I/O isolation (Reinforced isolation)
  • Half encapsulated , cooling by free air convection
  • -40~+70℃ wide working temperature
  • Built-in constant current limiting circuit
  • LED indicator for power on
  • 3 years warranty

Specifications

RSD-60G-24Specifications from the official datasheet (2026-07-09 edition)

OUTPUT

DC VOLTAGE
24V
RATED CURRENT
2.5A
CURRENT RANGE
0 ~ 2.5A
RATED POWER
60W
RIPPLE & NOISE (max.)Note.2
50mVp-p
VOLTAGE TOLERANCENote.3
±2.0%
LINE REGULATION
±0.2%
LOAD REGULATION
±0.2%
SETUP, RISE TIME
100ms, 60ms at full load
HOLD UP TIME (Typ.)
Please refer to page 5 Hold up Time( Load de-rating curve )

INPUT

VOLTAGE RANGE CONTINUOUS
9 ~ 36VDC
EFFICIENCY (Typ.)
90%
DC CURRENT (Typ.)
3A/24VDC
INRUSH CURRENT (Typ.)
20A/24VDC
INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2021-Comply with S1 level

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
27.6 ~ 32.4V Protection type : Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.
-40 ~ +55℃ (no derating) ; +70℃ @ 60% load by free air convection ; +70℃ (no derating with external base plate)
WORKING HUMIDITY
5 ~ 95% RH non-condensing
STORAGE TEMP.
-40 ~ +85℃
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes ; Mounting : compliance to IEC61373
OPERATING ALTITUDE
5000 meters

SAFETY & EMC

SAFETY STANDARDS
IEC 62368-1, UL 62368-1, AS/NZS 62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
WITHSTAND VOLTAGE
I/P-O/P:4KVDC I/P-FG:2.5KVDC O/P-FG:2.5KVDC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032Class A
RadiatedBS EN/EN55032Class B
Harmonic CurrentBS EN/EN61000-3-2-----
Voltage FlickerBS EN/EN61000-3-3-----; BS EN/EN55035
EMC IMMUNITY
ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, ±8KV air; Level 3, ±6KV contact
Radiated FieldBS EN/EN61000-4-3Level X, 20V/m
EFT / BurstBS EN/EN61000-4-4Level 3, 2KV at power
SurgeBS EN/EN61000-4-5Level 3,1KV Line-Line, Level 3, 2KV Line-Earth
ConductedBS EN/EN61000-4-6Level 3
RAILWAY STANDARD
Compliance to BS EN/EN45545-2 for fire protection ; BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC

OTHERS

MTBF
2738.8K hrs min. Telcordia SR-332 (Bellcore) ; 593.9K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
128*60*25mm (L*W*H)
PACKING
0.29Kg; 48pcs/14.9Kg/0.75CUFT
Test conditions and notes6
  1. 1. All parameters NOT specially mentioned are measured at 24,48VDC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Strongly recommended that external output capacitance should not exceed 5000uF.
  6. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

RSD-60G-24 Block Diagram
Block Diagram
RSD-60G-24 Input Under-Voltage Protection
Input Under-Voltage Protection
RSD-60G-24 Hold-up Time
Hold-up Time
RSD-60G-24 Efficiency vs Load & Vin Curve
Efficiency vs Load & Vin Curve
RSD-60G-24 Overload Protection
Overload Protection
RSD-60G-24 Derating Curve
Derating Curve
RSD-60G-24 R S D - 6 0 series
R S D - 6 0 series
RSD-60G-24 and share the same derating curve.
and share the same derating curve.
RSD-60G-24 R S D - 6 0 series
R S D - 6 0 series
RSD-60G-24 EN45545-2 Fire Test Conditions
EN45545-2 Fire Test Conditions
RSD-60G-24 Mechanical Specification
Mechanical Specification

Typical applications

  • Bus, tram, metro or railway system
  • Highly vibrating, highly dusty, extremely low or high temperature harsh environment
  • Wireless network
  • Telecom or datacom system
  • Industry control system

Downloads

FAQ

Can I use the RSD-60G-24 for a small 24V PLC or industrial control load?

Yes, as long as the load stays within 24V, 2.5A, and 60W. The converter is a constant-voltage model, so it is intended for equipment that requires a regulated 24V supply.

Is this converter a good fit for 24V field devices in a compact machine or panel?

It is suited to compact 24V loads because the body measures 128.0 × 60.0 × 25.0 mm and weighs 0.29 kg. Electrically, it provides up to 2.5A at 24V with 60W total output power.

Can the RSD-60G-24 be used in transportation or mobile automation equipment?

It can fit mobile equipment because it is specified to withstand 5G vibration. Its operating range of -40°C to +55°C at full load, or up to +70°C at 60% load (full load with an external base plate), also supports use in equipment exposed to changing ambient conditions.

Would this model work for a 24V communications or monitoring device powered from a wide DC source?

It can, provided the device needs a constant 24V output and draws no more than 2.5A or 60W. The listed input range is 9-36VDC, which allows a broad input window in the published specifications.

Is the RSD-60G-24 rated for outdoor installation?

The converter is specified for operation from -40°C to +70°C, with full load up to +55°C and derating above that unless base-plate mounted. No IP rating is included in the provided specs, so direct weather exposure should be avoided unless the unit is placed in a suitable enclosure.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8442673725739, "variants" :[{ "context":"default", "variant_id": 45712119857451, "sku":"RSD-60G-24", "inventory_qty" : 3, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well RSD-60G-24 DC-DC Converter - 60W - 9~36V in 24V out 2.5A
Mean Well

Mean Well RSD-60G-24 DC-DC Converter - 60W - 9~36V in 24V out 2.5A

RSD-60G-24 is the 24V output model of this series: rated current 2.5A, rated power 60W, typical efficiency 90%.

RSD-60 is a 60W enclosed type DC-DC reliable railway converter. This series is compliant with BS EN/EN50155/ IEC60571 railway standard, constituting three types of models with 4:1 wide but different input ranges 9~36V/18~72V/40~160V, suitable for railway and all kinds of transportation systems exploiting the frequently used standard input voltages such as 12V, 24V, 36V, 48V, 72V, 96V and 110V. Various output voltages, 3.3V, 5V, 12V and 24V are available for selection. This series has the capability of working under -40~+70℃, low ripple and noise, supreme EMC characteristics, 4KVDC I/P-OP, low enclosure profile 25mm and an interior with semi-potted silicone. It does not only well fits the in-car systems or the facilities by rails for railway, trams and buses but also can be used in the harsh environment with high vibration, high dust, extremely low or high temperature, etc.

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Ultra compact and 1U low profile(25mm)
  • 4:1 wide input range
  • No minimum load required
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity
  • 4000VDC I/O isolation (Reinforced isolation)
  • Half encapsulated , cooling by free air convection
  • -40~+70℃ wide working temperature
  • Built-in constant current limiting circuit
  • LED indicator for power on
  • 3 years warranty

Typical applications

  • Bus, tram, metro or railway system
  • Highly vibrating, highly dusty, extremely low or high temperature harsh environment
  • Wireless network
  • Telecom or datacom system
  • Industry control system
View product