💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well NTS-750-224AU True Sine Wave DC-AC Inverter 750W 230V out 24V in with AU Socket

fanless designhigh efficiency up to 93%200% peak power capabilitybuilt-in dip switch to adjust AC output voltagefrequency and work mode
SKU NTS-750-224AU
Log in to see price Trade pricing & online ordering for account holders
In stock
|

Overview

NTS-750-224AU is the model of this series: typical efficiency 93%.

NTS-750 is a 750W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high quality fan with low acoustic noise, 1500W peak power, adjustable AC output voltage and frequency, -25~+70℃ wide operating temperature range, complete protection features, and etc. combined with batteries, the NTS-750 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.

Features

  • Compact size and light weight
  • True sine wave output (THD<3%)
  • High surge power up to 1500W
  • Temperature controlled cooling fan
  • AC output voltage and frequency selectable by DIP S.W
  • No load dissipation <1.5W at standby saving mode
  • -25℃~+70℃ wide operating temperature
  • Power ON-OFF remote control
  • Front panel indicator for operation status
  • Protections : Input : Reverse polarity / DC low alarm / DC low shutdown / Over voltage Output : Short circuit / Overload / Over temp.
  • Battery over discharge protection(Low voltage disconnect)
  • Suitable for lead-acid or li-ion batteries
  • Remote controller (IRC1, IRC2, IRC3 accessory sold separate, please refer to: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1)
  • Support RS-232 communication(Communication cable order No.: RJ11-RS232, sold sperately)
  • Carry handle accessory available(Order NO.: Carry handle, sold separately)
  • Conformal coating
  • 3 years warranty

Specifications

NTS-750-224AUSpecifications from the official datasheet (2024-10-30 edition)

AC OUTPUT

RATED POWER(Continuous)
750W
OVER RATED POWER(3 Min.)
862W
PEAK POWER(10 Sec.)
1125W
SURGE POWER(30 Cycles)
1500W
AC VOLTAGE
Default setting set at 230VAC 200 / 220 / 230 / 240Vac selectable by DIP S.W
FREQUENCY
Default setting set at 50Hz±0.1Hz 50/60Hz selectable by DIP S.W
WAVEFORMNote.1
True sine wave (THD<3%)
AC REGULATION
±3.0% at rated output voltage
FRONT PANEL LED
Please see page5

DC INPUT

DC VOLTAGE
24V
VOLTAGE RANGE (Typ.)
20 ~ 33Vdc
DC CURRENT (Typ.)
38A
NO LOAD NON-SAVING MODE
10W
DISSIPATION (Typ.) SAVING MODE
1.4W
OFF MODE CURRENT DRAW
≦1mA
EFFICIENCY (Typ.)Note.1
93%
BATTERY TYPES
Lead Acid or li-ion

PROTECTION

FUSE (Internal)
40A*2
DC INPUT LOW ALARM
22±0.5Vdc
DC INPUT LOW SHUTDOWN
20±0.5Vdc
DC INPUT LOW RESTART
25±0.5Vdc
DC INPUT HIGH ALARM
31±0.5Vdc
DC INPUT HIGH SHUTDOWN
33±0.5Vdc
DC INPUT HIGH RESTART
30±0.5Vdc
BAT. POLARITY
By internal fuse open
OVER TEMPERATURE
Protection type : Shut down o/p voltage, re-power on to recover(except 112/124GFCI) Shut down o/p voltage,recovers automatically after temperature goes down(for 112/124GFCI)
OUTPUT SHORT
Protection type : Shut down o/p voltage, re-power on to recover
OVER LOAD (Typ.)
105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover
GFCI PROCTECTION
None

FUNCTION

REMOTE CONTROL DRY CONTACT
Power ON-OFF remote control by front panel dry contact connector (by RELAY), Open : Normal work ; Short : Remote off
REMOTE CONTROL ACCESSORY
Remote controller sold separately, Order No.: IRC1,IRC2,IRC3
RS-232 COMMUNICATION
RS-232 ~ RJ11 Type connector (Please refer to page 4 for more details)

ENVIRONMENT

WORKING TEMP.
-25 ~ +70℃(Refer to “Derating curve”)
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-30 ~ +70℃ / -22 ~ +158oF, 10 ~ 95% RH non-condensing
VIBRATION
10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
CB IEC62368-1,Dekra BS EN/EN62368-1,UL458, E13,EAC TP TC 004 approved;Design refer to AS/NZS 62368.1 (Please refer to next page “AC output socket” table for more details )
WITHSTAND VOLTAGE
DC I/P - AC O/P:3.0KVac AC O/P - FG:1.5KVac
EMC EMISSIONNote.4
ParameterStandardTest Level
FCC for 112,124,148 only(expect for Type-UN)RadiatedClass A
BS EN/EN55032(CISPR32) for 212,224,248 only(expect for Type-UN)RadiatedClass A
Harmonic CurrentBS EN/EN61000-3-2
Voltage FlickerBS EN/EN61000-3-3-----; BS EN/EN55024, BS EN/EN55035
EMC IMMUNITYNote.4
ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 2, 4KV contact
RadiatedBS EN/EN61000-4-3Level 2, 3V/m
Magnetic FieldBS EN/EN61000-4-8Level 1, 1A/m

OTHERS

MTBF
715.7K hrs min. Telcordia TR/SR-332 (Bellcore) ; 78K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
270*158*67mm (L*W*H)
PACKING
2.3Kg; 4pcs/ 10.2Kg/ 1.9CUFT
Test conditions and notes4
  1. 1.Efficiency, AC regulation and THD are tested by 600W, linear load at 12.5Vdc/25Vdc/50Vdc input voltage.
  2. 2.All parameters not specified above are measured at rated load, 25℃ of ambient temperature and set to factory setting.
  3. 3.Internal pre-start circuit, the setup time is 8s.
  4. 4.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

Technical drawings

NTS-750-224AU AC Output Socket
AC Output Socket
NTS-750-224AU DERATING CURVE
DERATING CURVE
NTS-750-224AU IRC1/2/3 Remote Controller (Accessory
IRC1/2/3 Remote Controller (Accessory
NTS-750-224AU Support RS-232 Communication
Support RS-232 Communication
NTS-750-224AU AC Output Voltage、Frequency、Power
AC Output Voltage、Frequency、Power
NTS-750-224AU LED STATUS
LED STATUS
NTS-750-224AU MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
NTS-750-224AU Accessory List
Accessory List
NTS-750-224AU TYPICALTYPICAL APPLICATIONAPPLICATION
TYPICALTYPICAL APPLICATIONAPPLICATION
NTS-750-224AU 4
4

Typical applications

  • Home and office appliancne
  • Power tools
  • Portable equipment
  • Vehiclc
  • Yacht
  • Off-grid solar power system
  • Wireless network
  • Telecom or datacom system

Downloads

FAQ

What is the Mean Well NTS-750-224AU designed for?

The NTS-750-224AU is a 750W true sine wave DC-AC inverter that converts 24V DC input to 230V AC output. It is suited to business and mobile power applications that need clean AC power from a 24V battery-based system. This model includes an AU socket and is part of Mean Well's NTS series.

Does this inverter produce true sine wave output?

Yes. The NTS-750-224AU provides a true sine wave output with total harmonic distortion below 3%. That makes it a better fit for equipment that is sensitive to output waveform quality than a modified sine wave inverter.

What are the main electrical specifications of the NTS-750-224AU?

This model is rated at 750W continuous power with 24V DC input and 230V AC output. It also supports high surge power up to 1500W. AC output voltage and frequency are selectable by DIP switch within the listed supported ranges.

Can the NTS-750-224AU be used with different battery types?

Yes. Mean Well specifies this inverter as suitable for both lead-acid and lithium-ion batteries. It also gives a DC input low-voltage alarm at 22V and shuts down at 20V (restart at 25V) to help protect the power source.

Is this inverter suitable for demanding temperature conditions?

Yes. The NTS-750-224AU is specified for a working temperature range of -25°C to +70°C, with load derating at higher temperatures per the manufacturer's derating curve. It is fan cooled and shuts down its output on over-temperature.

What protection and monitoring features are included?

This inverter includes protection for output short circuit, overload, over-temperature, and DC input low and high voltage (shutdown at 20V and 33V). It also has front panel status LEDs and supports power on-off remote control. Remote controller accessories are available separately.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8434010882347, "variants" :[{ "context":"default", "variant_id": 45678036386091, "sku":"NTS-750-224AU", "inventory_qty" : 5, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well NTS-750-224AU True Sine Wave DC-AC Inverter 750W 230V out 24V in with AU Socket
Mean Well

Mean Well NTS-750-224AU True Sine Wave DC-AC Inverter 750W 230V out 24V in with AU Socket

NTS-750-224AU is the model of this series: typical efficiency 93%.

NTS-750 is a 750W highly reliable off-grid true sine wave DC-AC power inverter. Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high quality fan with low acoustic noise, 1500W peak power, adjustable AC output voltage and frequency, -25~+70℃ wide operating temperature range, complete protection features, and etc. combined with batteries, the NTS-750 is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.

Features

  • Compact size and light weight
  • True sine wave output (THD<3%)
  • High surge power up to 1500W
  • Temperature controlled cooling fan
  • AC output voltage and frequency selectable by DIP S.W
  • No load dissipation <1.5W at standby saving mode
  • -25℃~+70℃ wide operating temperature
  • Power ON-OFF remote control
  • Front panel indicator for operation status
  • Protections : Input : Reverse polarity / DC low alarm / DC low shutdown / Over voltage Output : Short circuit / Overload / Over temp.
  • Battery over discharge protection(Low voltage disconnect)
  • Suitable for lead-acid or li-ion batteries
  • Remote controller (IRC1, IRC2, IRC3 accessory sold separate, please refer to: https://www.meanwell.com/webapp/product/search.aspx?prod=IRC1)
  • Support RS-232 communication(Communication cable order No.: RJ11-RS232, sold sperately)
  • Carry handle accessory available(Order NO.: Carry handle, sold separately)
  • Conformal coating
  • 3 years warranty

Typical applications

  • Home and office appliancne
  • Power tools
  • Portable equipment
  • Vehiclc
  • Yacht
  • Off-grid solar power system
  • Wireless network
  • Telecom or datacom system
View product