Overview

NSP-2400-60 is the 60V output model of this series: rated power 2400W, typical efficiency 93%.

The NSP-2400 series is a 2400W AC/DC power supply with PFC function, designed for high reliability and suitable for multiple industries. Key features include: compact size (325.8*107*41mm) for better space utilization in system installations, ultra-wide input range of 85~305Vac for global compatibility, up to 93% efficiency , programmable output voltage (0~120%) and current (0~100%), constant current design with 200% peak power capability, parallel output capacity up to 9600W, built-in CANBus communication interface, wide operating temperature range from -40 to +85℃ (+60℃ at full load), compliance with OVCⅢ, built-in Remote Control /Remote Sense/DC OK signal/auxiliary power, internal PCB coating, complete protections, certifications for multiple safety standards including 62368-1, 60601-1, 61558-1, 60335-1, 62477-1, and 61010-1, as well as 2 X MOPP compliance and extremely low leakage current (<500μA). It is suitable for BF-rated medical equipment and comes with a 5-years warranty, making it a highly cost-effective solution for industrial power supply needs.

Features

  • 85~305Vac input with PFC(277Vac available)
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1,Industrial 61558-1/-2-16/61010-1/-2-201, Energy converter 62477-1), SEMI F47 at 200Vac
  • 200% peak power capability
  • High efficiency up to 93%
  • Output voltage 0~120% and output current 0~100% programmable
  • Current sharing up to 9600W(3+1) for parallel use
  • Built in ORing MOS By request, Order NO. : NSP-2400-xxOR/MODOR
  • CANBus(Built in) or MODBus protocol (By request)
  • -40~85℃ wide range operation temperature(> +60℃ derating)
  • Extremely low leakage current<500uA, 2 x MOPP, suitable for BF medical applications
  • Built-in constant current limiting circuit
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in remote ON/OFF control/Remote Sense/ DC OK signal
  • Auxiliary 5Vdc and 12Vdc
  • Over voltage category Ⅲ (OVC Ⅲ)
  • Operating altitude up to 5000 meters
  • Built-in intelligent fan speed control, low noise <46dB
  • Conformal coating
  • 5 years warranty

Specifications

NSP-2400-60Specifications from the official datasheet (2026-06-12 edition)Download datasheet PDF

OUTPUT

DC VOLTAGE
60V
CURRENT
40A
CURRENT RANGE
0 ~ 40A
RATED POWER
2400W
PEAK CURRENTNote.2
80A
PEAK POWERNote.2
4800W
RIPPLE & NOISE (max.)Note.3
600mVp-p
VOLTAGE ADJ. RANGE
54 ~ 72V
VOLTAGE TOLERANCENote.4
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIMENote.5
1800ms, 60ms/115Vac; 1800ms, 60ms/230Vac; 1800ms, 60ms/277Vac at full load
HOLD UP TIME (Typ.)
12ms @ 70% load, 8ms @full load

INPUT

VOLTAGE RANGENote.6
85 ~ 305Vac 250 ~ 431Vdc
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
0.98/115Vac 0.95/230Vac 0.93/277Vac at full load
EFFICIENCY (Typ.)
93%
AC CURRENT (Typ.)
17A/115Vac 13A/230Vac 11A/277Vac
INRUSH CURRENT (Typ.)
COLD START 30A/115Vac 60A/230Vac 75A/277Vac
LEAKAGE CURRENT
Earth leakage current <500μA(rms)@277Vac ; Touch current<100μA(rms) @ 277Vac

PROTECTION

SHORT CIRCUIT PEAK POWER MODENote.7
Constant current limiting, unit will shut down after 5 Sec, AC repower on to recover. (2 Sec for 12V/15V models)
SHORT CIRCUIT CURRENT LIMITING MODENote.7
Constant current limiting, recovers automatically after abnormal condition is removed
OVERLOAD PEAK POWER MODENote.8
From 105% to 200% of rated output power, unit will shut down after 5 seconds of continuous operation. AC repower on to recover. (2 Sec for 12V/15V models)
OVERLOAD PEAK POWER MODENote.8
At >200% of rated output power, constant current limiting is activated. Unit will shut down after 5 seconds of continuous operation. AC repower on to recover. (2 Sec for 12V/15V models)
OVERLOAD CURRENT LIMITING MODENote.8
Constant current limiting, recovers automatically after abnormal condition is removed
OVER VOLTAGE
73 ~ 86V Protection type : Shut down and latch off output voltage, re-power on to recover
OVER TEMPERATURE
Shut down output voltage, recovers automatically after temperature goes down

FUNCTION

OUTPUT CURRENT PROGRAMMABLE(PC)
Adjustment of constant current level is allowable between 0 ~ 100% of rated current. Please refer to the User Manual.
OUTPUT VOLTAGE PROGRAMMABLE(PV)Note.9
Adjustment of output voltage is allowable to 0 ~ 120% of nominal output voltage. Please refer to the User Manual.
PARALLEL
Up to 9600W or (3+1) units. Please refer to the User Manual.
AUXILIARY POWER
5Vaux @ 0.2A Tolerance ±15%, ripple 150mVp-p 12Vaux @ 0.8A Tolerance ±15%, ripple 450mVp-p
REMOTE CONTROL
By electrical signal or dry contact Power ON: RC short Power OFF: RC open
REMOTE SENSE
Compensate voltage drop on the load wiring up to 0.5Vdc
DC OK SIGNAL
Contact rating(max.):5Vdc/10mA resistive load
CANBus(BUILT-IN) or MODBus(By Request) INTERFACE
Communication provides functions such as control, setting and monitoring
FAN NOISE (Typ.)Note.10
Built-in intelligent fan speed control detect by PSU'S internal temperature
FAN NOISE (Typ.) 10% load with Ta=25℃
38dB
FAN NOISE (Typ.) 70% load with Ta=25℃
41dB

ENVIRONMENT

WORKING TEMP.
-40 ~ +85℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 60℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC(Note 11~13)

SAFETY STANDARDS
ParameterStandard
CBIEC62368-1, IEC60335-1, IEC61558-1/-2-16, IEC61010-1/-2-201, IEC60601-1; IEC62477-1
DEKRABS EN/EN62368-1, BS EN/EN60335-1, BS EN/EN61558-1/-2-16, BS EN/EN61010-1/-2-201, BS EN/EN60601-1(3.2 Version);BS EN/EN62477-1
ULUL62368-1, ANSI/AAMI ES60601-1(3.2 Version),UL61010-1/-2-201
CQCGB4943.1
BSMICNS15598-1
EACTP TC 004
SEMI F47approved
KC/BISKC 62368-1 and BIS IS 13252(Part 1) certified, No stock, contact sales by request
ISOLATION LEVELNote.14
Primary-Secondary: 2xMOPP, Primary-Earth: 1xMOPP, Secondary-Earth: 1xMOPP
OVER VOLTAGE CATEGORYNote.15
IEC/EN 61558-1/-2-16 (OVC Ⅲ , altitude up to 2000M) ; IEC/EN/UL 62368-1 (OVC Ⅱ, altitude up to 5000M) ; IEC/EN 60335-1 (OVC Ⅱ, altitude up to 5000M) ; IEC/EN/ANSI/AAMI ES60601-1 (OVC Ⅱ, altitude up to 4000M) ; IEC/EN/UL 61010-1/-2-201 (OVC Ⅱ , altitude up to 5000M) ; IEC/EN 62477-1 (OVC Ⅱ , altitude up to 5000M)
SAFETY EXTRA-LOW VOLTAGE(SELV)
IEC/EN 61558-2-16 (SELV, 12 ~ 60V) ; IEC/EN 60335-1 (SELV, 12 ~ 36V) ; IEC/EN/UL 62368-1 (SELV/ES1, 12 ~ 48V)
WITHSTAND VOLTAGE
I/P-O/P:4KVac I/P-FG:2KVac O/P-FG:1.5KVac
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032(CISPR32),CNS 15936,GB/T 9254.1,KS C 9832Class B
ConductedBS EN/EN55014-1(CISPR14-1)
ConductedBS EN/EN55011(CISPR11)Class B
RadiatedBS EN/EN55032(CISPR32),CNS 15936,GB/T 9254.1,KS C 9832Class B
RadiatedBS EN/ENEN55014-1(CISPR14-1)
RadiatedBS EN/EN55011(CISPR11)Class B
Harmonic CurrentBS EN/EN61000-3-2(IEC61000-3-2),GB 17625.1Class A
Voltage FlickerBS EN/ EN61000-3-3(IEC61000-3-3)
EMC IMMUNITY

BS EN/EN55035(CISPR35),BS EN/EN61000-6-2(IEC61000-6-2),BS EN/EN60601-1-2(IEC60601-1-2), BS EN/EN55014-2(CISPR14-2),KS C 9835,SEMI F47 tested at 200Vac

ParameterStandardTest Level
ESDBS EN/ EN61000-4-2Level 4, 15KV air; Level 4, 8KV contact
RadiatedBS EN/ EN61000-4-3Level 3, 10V/m(80MHz~2.7GHz) Table 9, 9~28V/m(385MHz~5.78GHz)
EFT / BurstBS EN/ EN61000-4-4Level 3, 2KV
SurgeBS EN/ EN61000-4-5Level 4, 2KV/Line-Line 4KV/Line-Earth
ConductedBS EN/ EN61000-4-6Level 3, 10V
Magnetic FieldBS EN/ EN61000-4-8Level 4, 30A/m
Voltage Dips and InterruptionsBS EN/ EN61000-4-11>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

OTHERS

MTBF
566.1K hrs min. Telcordia SR-332 (Bellcore) ; 47.3K hrs min. MIL-HDBK-217F (25℃)
DIMENSION (L*W*H)
325.8*107*41mm
PACKING
2.32Kg;4pcs/10.3Kg/1.09CUFT
Test conditions and notes15
  1. 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
  2. 2. The peak power duration is 2 seconds for 12V/15V models and 5 seconds for all other models.
  3. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
  4. 4. Tolerance: includes set up tolerance, line regulation and load regulation.
  5. 5. Setup time is measured at the first cold start.
  6. 6. Derating may be required at low input voltages; refer to the "Static Characteristics" section for details.
  7. 7. Operation under stabilized output voltage may trigger protective shutdown.
  8. 8. For details on the overload protection mode, refer to the "Overload Protection Mode" section in the User Manual.
  9. 9. When the output voltage is adjusted via the PV function, the output ripple and noise may exceed the specified limits under certain operating conditions.
  10. 10. Fan noise measurement is performed in accordance with ISO 7779.
  11. 11. The Regulatory Compliance Mark (RCM) is applied on a voluntary basis. The equipment meets the relevant IEC or AS/NZS standards, or AS/NZS 3820 where applicable. The use of the RCM mark complies with AS/NZS 4417.1.
  12. 12. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  13. 13. The BIS marking may not be available for certain manufacturing sites or models. Please contact your MEAN WELL sales rep for further information.
  14. 14. MOPP is suitable for 100-240Vac input only.
  15. 15. The ambient temperature derating of 3.5℃/1000m with fanless models and 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

NSP-2400-60 Block Diagram
Block Diagram
NSP-2400-60 Derating Curve
Derating Curve
NSP-2400-60 Static Characteristics
Static Characteristics
NSP-2400-60 User Manual
User Manual
NSP-2400-60 User Manual (2)
User Manual (2)
NSP-2400-60 ◎ Others
◎ Others
NSP-2400-60 2.Output Voltage Programming(P.V)
2.Output Voltage Programming(P.V)
NSP-2400-60 3.Output Current Programming(P.C)
3.Output Current Programming(P.C)
NSP-2400-60 4.Remote Control
4.Remote Control
NSP-2400-60 4.Remote Control (2)
4.Remote Control (2)
NSP-2400-60 Illustration (page 7)
Illustration (page 7)
NSP-2400-60 6.Local Sense
6.Local Sense
NSP-2400-60 NSP-2400 series
NSP-2400 series
NSP-2400-60 PSU1
PSU1
NSP-2400-60 PSU1 (2)
PSU1 (2)
NSP-2400-60 ◎ DA,DB and GND are connected mutually in parallel.
◎ DA,DB and GND are connected mutually in parallel.

Typical applications

  • Industrial automation machinery/ control system
  • Security system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Network equipment
  • Telecom devices
  • Power sourcing equipment of PoE
  • Home automation
  • Medical devices
  • Supercapacitor

Downloads

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":15179014799726, "variants" :[{ "context":"default", "variant_id": 54562303639918, "sku":"NSP-2400-60", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well NSP-2400-60 2400W 60V Compact Power Supply 40A
Mean Well

Mean Well NSP-2400-60 2400W 60V Compact Power Supply 40A

NSP-2400-60 is the 60V output model of this series: rated power 2400W, typical efficiency 93%.

The NSP-2400 series is a 2400W AC/DC power supply with PFC function, designed for high reliability and suitable for multiple industries. Key features include: compact size (325.8*107*41mm) for better space utilization in system installations, ultra-wide input range of 85~305Vac for global compatibility, up to 93% efficiency , programmable output voltage (0~120%) and current (0~100%), constant current design with 200% peak power capability, parallel output capacity up to 9600W, built-in CANBus communication interface, wide operating temperature range from -40 to +85℃ (+60℃ at full load), compliance with OVCⅢ, built-in Remote Control /Remote Sense/DC OK signal/auxiliary power, internal PCB coating, complete protections, certifications for multiple safety standards including 62368-1, 60601-1, 61558-1, 60335-1, 62477-1, and 61010-1, as well as 2 X MOPP compliance and extremely low leakage current (<500μA). It is suitable for BF-rated medical equipment and comes with a 5-years warranty, making it a highly cost-effective solution for industrial power supply needs.

Features

  • 85~305Vac input with PFC(277Vac available)
  • Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1,Industrial 61558-1/-2-16/61010-1/-2-201, Energy converter 62477-1), SEMI F47 at 200Vac
  • 200% peak power capability
  • High efficiency up to 93%
  • Output voltage 0~120% and output current 0~100% programmable
  • Current sharing up to 9600W(3+1) for parallel use
  • Built in ORing MOS By request, Order NO. : NSP-2400-xxOR/MODOR
  • CANBus(Built in) or MODBus protocol (By request)
  • -40~85℃ wide range operation temperature(> +60℃ derating)
  • Extremely low leakage current<500uA, 2 x MOPP, suitable for BF medical applications
  • Built-in constant current limiting circuit
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in remote ON/OFF control/Remote Sense/ DC OK signal
  • Auxiliary 5Vdc and 12Vdc
  • Over voltage category Ⅲ (OVC Ⅲ)
  • Operating altitude up to 5000 meters
  • Built-in intelligent fan speed control, low noise <46dB
  • Conformal coating
  • 5 years warranty

Typical applications

  • Industrial automation machinery/ control system
  • Security system
  • Mechanical and electrical equipment
  • Electronic instruments, equipments or apparatus
  • Network equipment
  • Telecom devices
  • Power sourcing equipment of PoE
  • Home automation
  • Medical devices
  • Supercapacitor
View product