Overview
NTN-5K-248CAN is the model of this series: typical efficiency 93%.
NTN-5K is a 5KW highly reliable off-grid true sine wave DC-AC power inverter with built-in AC charger and UPS function(AC by-pass). Its key features include: digital design with MCU control, streamlined control circuitry that quickly responds to environmental changes and improves reliability, high quality fan with low acoustic noise, 10KW peak power, adjustable AC output voltage and frequency, -30~+70℃ wide. Operating temperature range, complete protection features, and etc. Combined with batteries, the NTN-5K is suitable for use in residential, commercial, marine, automobile, mine, construction site, and remote areas with no access to utility power, and the output can be used to power fans, TV, radio, phone charger, PC/laptop, lighting, induction stove, air conditioner, electromechanical tool, communication equipment, power distribution cabinet, outdoor camping equipment, marine AC power, factory equipment, and etc.
Features
- Combining AC/DC charger, DC/AC Inverter, AC by-pass & support external MPPT solar charger
- AC utility charge up to 4520W
- UPS function (AC by-pass) without interruption, transfer time <10ms
- True sine wave output (THD<3%)
- High surge power up to 10KW
- Parallel synchronized operation up to 30KW (5+1 unit)
- Temperature controlled cooling fan
- AC output voltage and frequency selectable by DIP S.W
- Protections : Input : Reverse polarity / DC low alarm / DC low shutdown / Over voltage Output : Short circuit / Overload / Over temp.
- Battery over discharge protection (low voltage disconnect)
- -30℃~+70℃ wide operating temperature
- Suitable for lead-acid or li-ion batteries
- Support MODBus-RTU(RS-485) or CANBus protocol communication
- Graphical user interface controller for status monitoring and control CMU2E/CMU2E-R
- Conformal coating
- 5 years warranty
Specifications
AC OUTPUT
- RATED POWER(Continuous)
- 5000W
- OVER RATED POWER(3 Min.)
- 5750W
- PEAK POWER(10 Sec.)
- 7500W
- SURGE POWER(30 Cycles)
- 10000W
- AC VOLTAGE
- Default setting set at 230VAC 200 / 220 / 230 / 240Vac selectable by DIP S.W
- FREQUENCY
- Default setting set at 50±0.1Hz 50/60Hz selectable by DIP S.W
- WAVEFORMNote. 1
- True sine wave (THD<3%)
- AC REGULATION
- ±3.0% at rated input voltage
DC INPUT
- DC VOLTAGE
- 48Vdc
- VOLTAGE RANGE (Typ.)
- 38 ~ 66Vdc
- DC CURRENT (Typ.)
- 120A
- NO LOAD DISSIPATION (Typ.) NON-SAVING MODE
- 1.4A
- NO LOAD DISSIPATION (Typ.) SAVING MODENote. 5
- Default disable, auto detect AC output load≦10W will be changed to saving mode <25W
- POWER OFF CURRENT DRAW
- ≦2mA
- EFFICIENCY (Typ.)Note. 1
- 93%
- BATTERY TYPES
- Lead Acid or li-ion
PROTECTION
- DC INPUT LOW ALARM
- 44±1Vdc
- DC INPUT LOW SHUTDOWN
- 38±1Vdc
- DC INPUT LOW RESTART
- 50±1Vdc
- DC INPUT HIGH ALARM
- 62±1Vdc
- DC INPUT HIGH SHUTDOWN
- 66±1Vdc
- DC INPUT HIGH RESTART
- 60±1Vdc
- REVERSE POLARITY
- No damage, re-power on to recover after fault condition is removed
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
- OUTPUT SHORT
- Shut down o/p voltage, re-power on to recover
- OVER LOAD (Typ.)
- 105 ~ 115% load for 180 sec., 115% ~ 150% load for 10 sec. Protection type : Shut down o/p voltage, re-power on to recover
- CIRCUIT BREAKER
- 35A
FUNCTION
- REMOTE CONTROL
- Set remote ON/OFF control by front panel dry contact connector(by RELAY), Open : AC output OFF ; Short : AC output ON
- COMMUNICATION
- MODBus-RTU (RS-485) / CANBus
AC UPS MODE
- AC INPUT RANGE
- 200/220/230/240Vac±16%, recover±13%
- FREQUENCY RANGE
- 45 ~ 65Hz
- TRASFER TIME(Typ.)
- 10ms inverter AC by pass
AC CHARGER
- BOOST CHARGE VOLTAGE
- Default 57.6Vdc
- FLOAT CHARGE VOLTAGE
- Default 55.2Vdc
- CHARGE VOLTAGE RANGE
- 40 ~ 60Vdc
- CONSTANT CURRENT
- 70A
- MAX. CHARGE POWER
- 4200W
- TEMPERATURE COMPENSATION
- By external NTC
- POWER FACTOR (Typ.)
- PF>0.98/230VAC at full load
- EFFICIENCY (Typ.)
- 93%
- AC CURRENT (Typ.)
- 25A/230VAC
- INRUSH CURRENT (Typ.)
- 50A/230VAC
- LEAKAGE CURRENT(Peak)
- 4.7mA/264VAC
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃(Refer to “Derating curve”)
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -30 ~ +70℃ / -22 ~ +158℉, 10 ~ 95% RH non-condensing
- VIBRATION
- 10 ~ 500Hz, 3G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- CB IEC62368-1, UL62368-1, CSA C22.2 No. 62368-1 , TUV BS EN/ EN62368-1 , AS/NZS 62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGENote. 6
- DC I/P - AC:3.0KVAC AC - FG:1.5KVAC
- ISOLATION RESISTANCENote. 6
- DC I/P - AC O/P, DC I/P - FG, AC O/P - FG: 100M ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSIONNote.4
-
Parameter Standard Test Level Radiated BS EN/ EN55032(CISPR32), FCC Class A Conducted BS EN/ EN55032(CISPR32), FCC Class A Harmonic Current BS EN/ EN61000-3-12 Class A Voltage Flicker BS EN/ EN61000-3-11 - EMC IMMUNITYNote.4
-
BS EN/EN55035, EN61000-6-2
Parameter Standard Test Level ESD BS EN/ EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/ EN61000-4-3 Level 3 EFT / Burst BS EN/ EN61000-4-4 Level 3 Surge BS EN/ EN61000-4-5 Level 4, 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/ EN61000-4-6 Level 3 Magnetic Field BS EN/ EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/ EN61000-4-34 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 200.9K hrs min. Telcordia TR/SR-332 (Bellcore) ; 17.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 460*211*83.5mm (L*W*H)
- PACKING
- 10.5Kg; 1pcs/ 10.5Kg/ 1.25CUFT
Test conditions and notes6
- 1.Efficiency, AC regulation and THD are tested by 75% load, linear load at 25Vdc/50Vdc/400Vdc input voltage.
- 2.All parameters not specified above are measured at 25Vdc/50Vdc/400Vdc input and 25℃ of ambient temperature and set to factory setting.
- 3.The tolerance of each voltage value by models is: 224→±0.5V; 248→±1V; 2380→±5V.
- 4.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 5.Saving mode only activates when the unit is used independently and the RPL switch is in the ON position.
- 6.During withstand voltage and isolation resistance testing, the screw "A" shall be temporarily removed, and shall be installed back after the testing.
Technical drawings
Typical applications
- Home and office appliance
- Power tools
- Portable equipment
- Vehiclc
- Yacht
- Off-grid solar power system
- Wireless network
- Telecom or datacom system
Downloads
Datasheet1
FAQ
What is the Mean Well NTN-5K-248CAN designed to do?
The NTN-5K-248CAN is a multi-function unit that combines an AC-DC charger, a DC-AC true sine wave inverter for the load, and an AC bypass function for the load. It is intended for high-power 48V battery-based systems that need reliable 230V AC output in one integrated platform.
What are the main output and power capabilities of this inverter?
This model is rated for 5000W continuous power, 5750W for 3 minutes, 7500W peak for 10 seconds and 10000W surge for 30 cycles. It provides pure sine wave output with THD below 3%, which is important for demanding electrical loads.
Can the NTN-5K-248CAN be used in larger or expandable power systems?
Yes. Up to 6 units can be connected in parallel on the AC output using the built-in active current sharing function; total output current must not exceed the rated current per unit x number of units x 95%. Three NTN-5K units can also be set by DIP switch for 3Ø 4-wire output.
Is this model compatible with different battery types?
Yes, the NTN-5K-248CAN is compatible with both lead acid (flooded, Gel and AGM) and li-ion batteries. That makes it suitable for a wider range of industrial, backup power, and energy storage applications using a 48V battery system.
Is the NTN-5K-248CAN suitable for harsh or enclosed environments?
This model has a working temperature range of -30 to +70 degrees C, with load derating at higher temperatures per the derating curve. Working humidity is 20% to 90% RH non-condensing and it is vibration-rated to 10-500Hz, 3G, which suits enclosed or industrial installations.
What monitoring and control options are available on this inverter?
The NTN-5K-248CAN includes built-in Modbus-RTU via RS-485 and CAN bus communication for system monitoring and integration. It also supports built-in remote ON/OFF control, and optional intelligent controllers such as the CMU2E and CMU2E-R are available separately.
What protection features are included in the NTN-5K-248CAN?
This model protects the DC input against reverse polarity, low voltage (alarm at 44V, shutdown at 38V) and high voltage (alarm at 62V, shutdown at 66V). On the AC output side, it includes short circuit, overload, and over temperature protection, plus a 35A circuit breaker, to help safeguard the unit during abnormal conditions.
What certifications and warranty come with this model?
The NTN-5K-248CAN is approved to CB IEC62368-1, UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1 and EAC TP TC 004, with EMC emissions to EN55032 and FCC Class A. The spec sheet does not state a warranty term, so please confirm warranty coverage with us before ordering.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NTN-5K Models
9 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.