Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SDR-120-12 is the 12V output model of this series: rated current 10A, rated power 120W, typical efficiency 89%.
Features
- High efficiency 91% and low power dissipation
- 150% peak load capability
- Built-in active PFC function, PF>0.93
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508 (industrial control equipment) approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- Built-in DC OK relay contact
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 10A
- CURRENT RANGE
- 0 ~ 10A
- RATED POWER
- 120W
- PEAK CURRENT
- 15A
- PEAK POWERNote.6
- 180W (3 sec.)
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p
- VOLTAGE ADJ. RANGE
- 12 ~ 14V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 1500ms, 60ms/230VAC 3000ms, 60ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 20ms/230VAC 20ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.7
- 88 ~ 264VAC 124 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- 0.93/230VAC 0.96/115VAC at full load
- EFFICIENCY (Typ.)
- 89%
- AC CURRENT (Typ.)
- 1.4A/115VAC 0.7A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage >150% rated power, constant current limiting with auto-recovery within 3 seconds and shut down o/p voltage after 3 seconds
- OVER VOLTAGE
- 14 ~ 17V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- 95℃±5℃ (TSW) detect on heatsink of power switch Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- DC OK REALY CONTACT RATINGS (max.)
- 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC
- SAFETY STANDARDS
- UL508, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004, BSMI CNS15598-1 approved;(meet BS EN/EN60204-1)
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32), BS EN/EN61204-3 Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS15936 Class B
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3, heavy industry level, EAC TP TC 020, SEMI F47 approved
OTHERS
- MTBF
- 1764.6K hrs min. Telcordia SR-332 (Bellcore) ; 292.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 40*125.2*113.5mm (W*H*D)
- PACKING
- 0.67Kg; 20pcs/14.4Kg/1.0CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
- 6. 3 seconds max., please refer to peak loading curves.
- 7. Derating may be needed under low input voltage. Please check the derating curve for more details.
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Certificates4
Test reports1
FAQ
Can I use the Mean Well SDR-120-12 for a PLC or industrial control panel that needs 12V DC?
Yes, this model is a fit for PLC and industrial control panels that require a 12V DC supply and stay within 10A and 120W total load. It is a DIN rail power supply, and its 125.2 x 113.5 x 40.0 mm housing suits slim control cabinet layouts.
Is the SDR-120-12 suitable for building management or cabinet-based control systems?
It can be used in building management and cabinet-based control systems when the equipment needs 12V DC and the total demand does not exceed 10A or 120W. The 88-264VAC input range also makes it suitable for standard AC-fed control enclosures.
Can this 12V DIN rail power supply run multiple 12V industrial automation loads in one enclosure?
It can support multiple 12V automation loads in one enclosure if the combined load remains within 10A and 120W. As a single output DIN rail unit with a 125.2 x 113.5 x 40.0 mm profile, it is intended for compact industrial control cabinet use.
How does the SDR-120-12 compare with other Mean Well SDR series models?
The SDR-120-12 is 120W at 12V and 10A (adjustable 12-14V). Its SDR-120 series siblings are the SDR-120-24 at 120W, 24V, 5A (24-28V adjustable) and the SDR-120-48 at 120W, 48V, 2.5A (48-55V adjustable). All three share the 88-264VAC input with PFC, DC OK relay contact and 40 x 125.2 x 113.5 mm housing; typical efficiency is 89% for the 12V model, 91% for the 24V and 90.5% for the 48V model.
Is the SDR-120-12 meant for indoor control cabinets or exposed outdoor conditions?
It is designed for use in control cabinets and enclosures, with DIN rail mounting and an operating temperature range of -25°C to +70°C (with derating per the derating curve). No IP rating is listed on the datasheet, so it should be installed as an enclosure-mounted industrial power supply rather than exposed outdoor equipment.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SDR-120 Models
2 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well SDR-120-24 Single Output Industrial Power Supply 120W 24V 5A - DIN Rail | 120W | 24V | 5A | IP20 | View |
| Mean Well SDR-120-48 Single Output Industrial Power Supply 120W 48V 2.5A - DIN Rail | 120W | 48V | 2.5A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.