Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SDR-480P-24 is the 24V output model of this series: rated current 20A, rated power 480W, typical efficiency 94%.
Features
- Current sharing up to 3840W(7+1)
- High efficiency 94% and low power dissipation
- 150% peak load capability
- Built-in active PFC function, PF>0.94
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- Can be installed on DIN rail TS-35/7.5 or 15
- UL 508(industrial control equipment)approved
- BS EN/EN61000-6-2(BS EN/EN50082-2) industrial immunity level
- Built-in DC OK relay contact
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 20A
- CURRENT RANGE
- 0 ~ 20A
- RATED POWER
- 480W
- PEAK CURRENT
- 30A
- PEAK POWERNote.6
- 720W (3sec.)
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p
- VOLTAGE ADJ. RANGE
- 24 ~ 28V
- VOLTAGE TOLERANCENote.3
- ±1.2%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 1500ms, 150ms/230VAC 3000ms, 150ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 14ms/230VAC at full load
INPUT
- VOLTAGE RANGENote.7
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- 0.94/230VAC 0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 94%
- AC CURRENT (Typ.)
- 5A/115VAC 2.5A/230VAC
- INRUSH CURRENT (Typ.)
- 40A/115VAC 80A/230VAC
- LEAKAGE CURRENT
- <0.6mA / 240VAC
PROTECTION
- OVERLOAD
- Normally works within 110 ~ 150% rated output power for more than 3 seconds and then shut down o/p voltage with auto-recovery >150% rated power, constant current limiting with auto-recovery within 2 seconds and may cause to shut down if over 2 seconds
- OVER VOLTAGE
- 29 ~ 33V Protection type : Shut down o/p voltage with auto-recovery or re-power on to recovery
- OVER TEMPERATURE
- 105℃±5℃ (TSW : detect on heatsink of power switch) Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- DC OK REALY CONTACT RATINGS (max.)
- 60Vdc/0.3A, 30Vdc/1A, 30Vac/0.5A resistive load
- CURRENT SHARING
- Please see the Function Manual
ENVIRONMENT
- WORKING TEMP.Note.5
- -25 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- Component:10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC60068-2-6
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL508, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004, BSMI CNS15598-1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC O/P-DC OK:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, CNS15936
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), BS EN/EN61204-3, heavy industry level, EAC TP TC 020, SEMI F47 approved
OTHERS
- MTBF
- 969.8K hrs min. Telcordia SR-332 (Bellcore) ; 118.6K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 85.5*125.2*128.5mm (W*H*D)
- PACKING
- 1.6Kg; 8pcs/13.8Kg/0.9CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Installation clearances : 40mm on top, 20mm on the bottom, 5mm on the left and right side are recommended when loaded permanently with full power. In case the adjacent device is a heat source, 15mm clearance is recommended.
- 6. 3 seconds peak power max. and the average output power should not exceed the rate power.
- 7. Derating may be needed under low input voltage. Please check the derating curve for more details.
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Certificates5
Test reports1
FAQ
Can the SDR-480P-24 be used for 24V PLC and factory automation systems?
Yes. The SDR-480P-24 provides 24V output at up to 20A with 480W total power, which fits many 24V PLC, industrial control, and automation cabinet loads. Its DIN rail format is also appropriate for structured panel layouts.
Is the SDR-480P-24 a good fit for 24V building automation panels?
It is suitable for 24V building automation and control panel applications that need up to 480W and 20A. The 90-264VAC input range allows it to be used with common AC mains feeds in centralized electrical enclosures.
Can I use the SDR-480P-24 to supply multiple 24V control devices from one DIN rail power supply?
Yes, provided the combined 24V load does not exceed 20A or 480W. That makes it relevant for cabinets powering several 24V relays, sensors, controllers, or automation devices from one DIN rail supply.
How does the SDR-480P-24 compare with the other SDR series models?
The SDR-480P series datasheet lists two models: the SDR-480P-24 at 480W, 24V, 20A (adjustable 24-28V) and the SDR-480P-48 at 480W, 48V, 10A (adjustable 48-55V). Both share the same 90-264VAC input, active PFC, 94% typical efficiency, 720W 3-second peak power, DC OK relay and current sharing function, so choose by the output voltage your load needs.
Should the SDR-480P-24 be used inside a cabinet or exposed directly to the environment?
This DIN rail model is best matched to control cabinet or enclosure installations where the ambient temperature stays within -25°C to +70°C, with output derating at higher temperatures per the derating curve. Its 85.5 × 125.2 × 128.5 mm (W × H × D) housing is sized for panel mounting, and the published specs are framed around industrial cabinet use.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SDR-480P Models
1 other model| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well SDR-480P-48 Single Output Industrial Power Supply 480W 48V 10A - DIN Rail | 480W | 48V | 10A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.