Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SE-450-15 is the 15V output model of this series: rated current 30A, rated power 450W, typical efficiency 84%.
Features
- AC input active surge current limiting
- AC input range selected by switch
- Protections: Short circuit /Overload / Over voltage / Over temperature
- Forced air cooling by built-in DC ball bearing fan
- Built-in remote sense function
- LED indicator for power on
- UL approved
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- RATED CURRENT
- 30A
- CURRENT RANGE
- 0 ~ 30A
- RATED POWER
- 450W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- 13.5 ~ 16.5V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1500ms, 50ms/230VAC 1500ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 12ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 132VAC / 180 ~ 264VAC selected by SW 254 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT (Typ.)
- 10A/115VAC 6A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 55A/230VAC
- LEAKAGE CURRENT
- <2.5mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 150% rated output power Protection type : Shut down o/p voltage, re-power on to recovery
- OVER VOLTAGE
- 18 ~ 21V Protection type : Shut down o/p voltage, re-power on to recovery
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -10 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃,10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.05%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY
- SAFETY STANDARDS
- UL62368-1, EAC TP TC 004 approved; Design refer to BS EN/EN62368-1
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
OTHERS
- MTBF
- 1557.5 K hrs min. Telcordia SR-332 (Bellcore) ; 224.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 225*124*50mm (L*W*H)
- PACKING
- 1.25Kg;12PCS/16Kg/1CUFT
Test conditions and notes5
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 5. This power supply does not meet the harmonic current requirements outlined by BS EN/EN61000-3-2. Please do not use this power supply under the following conditions: a) the end-devices is used within the European Union, and b) the end-devices is connected to public mains supply with 220Vac or greater rated nominal voltage, and c) the power supply is: - installed in end-devices with average or continuous input power greater than 75W, or - belong to part of a lighting system Exception: Power supplies used within the following end-devices do not need to fulfill BS EN/EN61000-3-2 a) professional equipment with a total rated input power greater than 1000W; b) symmetrically controlled heating elements with a rated power less than or equal to 200W
Technical drawings
Downloads
FAQ
Can I use the SE-450-15 for a 15V automation or test bench power rail?
Yes, this unit provides constant voltage 15V output rated at 30A and 450W. It is appropriate for automation or bench systems specifically designed for a 15V DC rail within that load range.
Is the SE-450-15 suitable for 15V industrial sensors, controllers, or embedded assemblies?
It can be used where the connected equipment requires regulated 15V DC and the total draw stays within 30A and 450W. Because it is a constant voltage model, it matches systems built around a fixed 15V supply.
Can the SE-450-15 power a centralized 15V DC load in a production machine?
Yes, for machines that distribute a 15V DC bus to multiple subsystems, this model offers up to 30A at 15V. Its switch-selectable 90-132VAC / 180-264VAC input also makes it suitable for sites on 115VAC or 230VAC supplies.
Can the SE-450-15 be used in unconditioned spaces or outdoors?
The operating temperature is specified as -10°C to +60°C, so temperature-wise it is intended for that range. The specs do not list an IP rating, so it should generally be placed in an indoor or protected enclosure rather than exposed outdoor conditions.
What are the differences between the SE-450-15 and the other SE-450 models?
The listed SE-450 variants are 3.3V at 75A and 247.5W, 5V at 75A and 375W, 12V at 37.5A and 450W, 15V at 30A and 450W, 24V at 18.8A and 451.2W, 36V at 12.5A and 450W, and 48V at 9.4A and 451.2W. The SE-450-15 is the 15V version in that series, with output current set at 30A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SE-450 Models
6 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well SE-450-5 Power Supply 375W 5V 75A | 375W | 5V | 75A | View |
| Mean Well SE-450-48 Power Supply 450W 48V 9.4A | 451.2W | 48V | 9.4A | View |
| Mean Well SE-450-36 Power Supply 450W 36V 12.5A | 450W | 36V | 12.5A | View |
| Mean Well SE-450-3.3 Power Supply 247.5W 3.3V 75A | 247.5W | 3.3V | 75A | View |
| Mean Well SE-450-24 Power Supply 450W 24V 18.8A | 451.2W | 24V | 18.8A | View |
| Mean Well SE-450-12 Power Supply 450W 12V 37.5A | 450W | 12V | 37.5A | View |