Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SMA01L-09 is the model of this series: rated power 1W, typical efficiency 77%.
Features
- 1500VDC I/O isolation
- 3000VDC I/O isolation(optional)
- Operating temperature range of -40 ~ +85℃ without derating
- Internal SMD technology
- Built-in EMI filter
- Cooling by free air convection
- Non-conductive plastic case
- Dual in line package
- Industry standard pinout
- 100% burn-in test
- Low cost / High reliability
- 2 years warranty
Specifications
SELECTION GUIDE
- DC OUTPUT VOLTAGE
- 9V
- OUTPUT CURRENT RANGE
- 0 ~ 110mA
- EFFICIENCY(Typ.)
- 77%
OUTPUT
- RATED POWER
- 1W
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p
- LINE REGULATIONNote.3
- ±1.2% for 1% input variation
- LOAD REGULATIONNote.4
- ±8.0%
- VOLTAGE ACCURACY
- ±2.0%
- SWITCHING FREQUENCY(Typ.)
- 100KHz
INPUT
- VOLTAGE RANGE
- 4.5 ~ 5.5V
- NORMAL VOLTAGE
- 5V
- INPUT CURRENT Full load
- 265mA
- INPUT CURRENT No load
- 32mA
- PROTECTION (FUSE RECOMMENDED)
- 500mA
- FILTER
- Capacitor type
PROTECTION
- OVERLOAD
- Momentary Protection type : Broken
- SHORT CIRCUIT
- Momentary Protection type : Broken
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +90℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.05% / ℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION CAPACITANCE
- 80pF max.
- EMI RADIATION
- Compliance to BS EN/EN55032 Class B, FCC part 15 Class B, EAC TP TC 020
- EMS IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8 light industry level, criteria A, EAC TP TC 020
OTHERS
- MTBF
- 700khrs min. MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 12.7*10.16*7.1mm or 0.50"*0.40"*0.28" inch for 5V,12V input ; 12.7*10.16*7.62mm or 0.50"*0.40"*0.30" inch for 24V input
- PACKING
- 1.6g ; 40pcs/per tube, 6000pcs/150 tube/per carton
Test conditions and notes4
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 20% to 100% rated load.
Technical drawings
Downloads
FAQ
Can I use the SMA01L-09 for a compact 9V rail in embedded or industrial electronics?
Yes, for small 9V electronics that fit within the converter's 1W rating. The SMA01L-09 accepts 4.5~5.5V input and provides a constant-voltage 9V output. That makes it suitable for low-power 9V auxiliary rails rather than higher-power 9V loads.
Is this a good choice for a low-power 9V interface or signal-conditioning stage in automation hardware?
It can be, provided the 9V stage stays within 1W. The converter is designed for 4.5~5.5V input conditions and outputs regulated 9V constant voltage, which aligns with small signal or interface sections. Its compact package also suits space-limited control electronics.
Can the SMA01L-09 be used in a small instrumentation circuit that needs 9V from a 5V-class source?
Yes, if the source stays within 4.5~5.5V and the instrumentation load is within 1W. The unit's 12.7 × 10.16 × 7.1 mm dimensions and 1.6g weight are useful where PCB or enclosure space is tight. It is intended for compact electronics, not larger 9V subsystems.
Would this converter fit a 9V communications or monitoring subassembly inside equipment?
It can fit small communications or monitoring subassemblies that require regulated 9V and stay within the 1W rating. The output mode is constant voltage, which is appropriate for electronics expecting a stable 9V rail. The input must remain in the 4.5~5.5V range.
What is the difference between the SMA01L-09 and the other SMA01L output options?
This series shares the same 1W rating and 4.5~5.5V input range across the sibling models. The SMA01L-09 provides 9V output and lists 110mA, while SMA01L-05 is 5V and 200mA, SMA01L-12 is 12V and 84mA, and SMA01L-15 is 15V and 67mA. The selection point is the required output voltage and the listed current for each version.
Can the SMA01L-09 be used outdoors or in cold industrial environments?
Its specified operating temperature range is -40°C to +90°C, so it covers both cold and hot operating conditions. The provided specs do not list an IP rating, so the converter should not be assumed to be outdoor-rated against dust or water. It is best used inside protected equipment unless separate enclosure protection is provided.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SMA01 Models
11 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.