DDR-120A-12 is the 12V output model of this series: rated current 8.3A, rated power 99.6W, typical efficiency 88.5%.
DDR-120 series is a 120W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width (32mm), 2:1 wide input voltage, fanless design, -40~+70℃ wide operating temperature, 4KVdc I/O isolation, 150% peak load, adjustable output voltage and full protective functions. This series of models has various input options: 9~18V / 16.8~33.6V / 33.6~67.2V / 67.2~154V and various output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication system and other fields. Suitable applications include DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.
Features
- Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
- Width only 32mm
- 2:1 wide input range
- -40~+70℃ wide working temperature
- 150% peak load capability
- DC output adjustable
- Cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15
- Protections: Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
- 4KVdc I/O isolation(Reinforced isolation)
- Conformal coating
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 8.3A
- CURRENT RANGE
- 0 ~ 8.3A
- RATED POWER
- 99.6W
- PEAK CURRENT
- 12.45A
- PEAK POWERNote.5
- 150W (3sec.)
- RIPPLE & NOISE (max.)Note.2
- 50mVp-p
- VOLTAGE ADJ. RANGE
- 9 ~ 14V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 500ms, 60ms @12Vdc
- HOLD UP TIME (Typ.)
- Please refer to page 7 Hold up Time( Load de-rating curve )
INPUT
- VOLTAGE RANGENote.4
- 9 ~ 18Vdc
- EFFICIENCY (Typ.)
- 88.5%
- DC CURRENT (Typ.)
- 11.2A @12Vdc
- INRUSH CURRENT (Typ.)
- 5A @12Vdc
- INTERRUPTION OF VOLTAGE SUPPLY
- EN50155:2021-comply with S1 level
PROTECTION
- OVERLOAD
- Normally works within 150% rated output power for more than 3 seconds and then constant current protection 105~135% rated output power with auto-recovery
- OVER VOLTAGE
- 14.4 ~ 16.8V Protection type : Shut down o/p voltage, re-power on to recover
- REVERSE POLARITY
- By internal MOSFET, no damage, recovers automatically after fault condition removed
- UNDER VOLTAGE LOCKOUT
- 12Vin (A - type) :Power ON≥9V , OFF≤8.5V
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 5 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 5 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 55℃)
- VIBRATION
- Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
- OPERATING ALTITUDE
- 5000 meters
SAFETY & EMC
- SAFETY STANDARDS
- IEC 62368-1, UL 62368-1, EAC TP TC 004, AS/NZS 62368.1 approved; Design refer to UL508
- WITHSTAND VOLTAGE
- I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:2.5KVdc
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25℃/ 70% RH
- EMC EMISSIONNote 6
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class B Radiated BS EN/EN55032 Class B Voltage Flicker BS EN/EN61000-3-3 ----- Harmonic Current ----- ----- - EMC IMMUNITYNote 6
-
BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 3, 6KV contact; criteria A Radiated BS EN/EN61000-4-3 Level 3, 10V/m; criteria A EFT / Burst BS EN/EN61000-4-4 Level 3, 2KV; criteria A Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-FG ;criteria A Conducted BS EN/EN61000-4-6 Level 3, 10V; criteria A Magnetic Field BS EN/EN61000-4-8 Level 4, 30A/m; criteria A - RAILWAY STANDARD
- Compliance to BS EN/EN45545-2 for fire protection ; Meet BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC (except for 9~18Vin)
OTHERS
- MTBF
- 1769.5K hrs min. Telcordia SR-332 (Bellcore) ; 214.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 32*125.2*102mm (W*H*D)
- PACKING
- 510g; 28pcs/15.3Kg/1.23CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at normal input (A:12Vdc , B:24Vdc) , rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltage. Please check the derating curve for more details.
- 5. 3 seconds max., please refer to peak loading curves.
- 6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Bus,tram,metro or railway system
- Industrial control system
- Semiconductor fabrication equipment
- Factory automation
- Electro-mechanical
- Wireless network
- Telecom or datacom system
Downloads
FAQ
Can I use the DDR-120A-12 to power 12V embedded systems in a DIN rail control panel?
Yes. The DDR-120A-12 delivers 12V at up to 8.3A (99.6W), which suits many embedded controllers and single-board computers mounted in DIN rail enclosures. Its 9–18V DC input range is designed for battery-bus or low-voltage DC distribution systems commonly found in telecom and mobile equipment.
Is the DDR-120A-12 suitable for powering 12V sensors and I/O modules in industrial automation?
It can work well for sensor loops and I/O modules that run on 12V DC, provided total current draw stays within 8.3A. The 4KVdc input-to-output isolation helps protect sensitive measurement equipment from electrical noise in industrial environments.
Can I use this converter to turn a 12V battery bank into a regulated 12V rail?
The DDR-120A-12 accepts 9–18V DC input, so a nominal 12V battery source falls within range. It provides a regulated, isolated 12V output at up to 8.3A, which is useful for isolating sensitive loads from battery voltage fluctuations in mobile or off-grid installations. Note that output derating may be needed at low input voltage; check the derating curve.
Will the DDR-120A-12 operate reliably in an unheated outdoor cabinet during winter?
The DDR-120A-12 is rated for an operating temperature range of -40°C to +70°C (with derating at the upper end per the derating curve), so it can handle extreme cold. It is rated for 5–95% RH non-condensing, so the enclosure should protect it from direct moisture and condensation.
How does the DDR-120A-12 compare to other models in the DDR-120 series?
The DDR-120A sub-series accepts 9–18V DC input and comes in 12V (99.6W, 8.3A), 24V (100.8W, 4.2A), and 48V (100.8W, 2.1A) output variants. The DDR-120B accepts 16.8–33.6V input, the DDR-120C accepts 33.6–67.2V input, and the DDR-120D accepts 67.2–154V input, each available in 12V, 24V, and 48V outputs at 120W. All share the same 125.2 x 102.0 x 32.0 mm DIN rail form factor.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other DDR-120A Models
2 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well DDR-120A-48 DC-DC Converter - 100.8W - 9~18V in 48V out 2.1A | 100.8W | 48V | 2.1A | IP20 | View |
| Mean Well DDR-120A-24 DC-DC Converter - 100.8W - 9~18V in 24V out 4.2A | 100.8W | 24V | 4.2A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.