💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well DDR-120A-12 DC-DC Converter - 99.6W - 9~18V in 12V out 8.3A

2:1 or 4:1 wide input rangefanless design4KVdc I/O isolationultra slim dimensions
SKU DDR-120A-12
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 13 in this family

DDR-120A-12
In stock
|

Overview

DDR-120A-12 is the 12V output model of this series: rated current 8.3A, rated power 99.6W, typical efficiency 88.5%.

DDR-120 series is a 120W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width (32mm), 2:1 wide input voltage, fanless design, -40~+70℃ wide operating temperature, 4KVdc I/O isolation, 150% peak load, adjustable output voltage and full protective functions. This series of models has various input options: 9~18V / 16.8~33.6V / 33.6~67.2V / 67.2~154V and various output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication system and other fields. Suitable applications include DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Width only 32mm
  • 2:1 wide input range
  • -40~+70℃ wide working temperature
  • 150% peak load capability
  • DC output adjustable
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
  • 4KVdc I/O isolation(Reinforced isolation)
  • Conformal coating
  • 3 years warranty

Specifications

DDR-120A-12Specifications from the official datasheet (2026-09-10 edition)

OUTPUT

DC VOLTAGE
12V
RATED CURRENT
8.3A
CURRENT RANGE
0 ~ 8.3A
RATED POWER
99.6W
PEAK CURRENT
12.45A
PEAK POWERNote.5
150W (3sec.)
RIPPLE & NOISE (max.)Note.2
50mVp-p
VOLTAGE ADJ. RANGE
9 ~ 14V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±1.0%
SETUP, RISE TIME
500ms, 60ms @12Vdc
HOLD UP TIME (Typ.)
Please refer to page 7 Hold up Time( Load de-rating curve )

INPUT

VOLTAGE RANGENote.4
9 ~ 18Vdc
EFFICIENCY (Typ.)
88.5%
DC CURRENT (Typ.)
11.2A @12Vdc
INRUSH CURRENT (Typ.)
5A @12Vdc
INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2021-comply with S1 level

PROTECTION

OVERLOAD
Normally works within 150% rated output power for more than 3 seconds and then constant current protection 105~135% rated output power with auto-recovery
OVER VOLTAGE
14.4 ~ 16.8V Protection type : Shut down o/p voltage, re-power on to recover
REVERSE POLARITY
By internal MOSFET, no damage, recovers automatically after fault condition removed
UNDER VOLTAGE LOCKOUT
12Vin (A - type) :Power ON≥9V , OFF≤8.5V

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
5 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 5 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 55℃)
VIBRATION
Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
OPERATING ALTITUDE
5000 meters

SAFETY & EMC

SAFETY STANDARDS
IEC 62368-1, UL 62368-1, EAC TP TC 004, AS/NZS 62368.1 approved; Design refer to UL508
WITHSTAND VOLTAGE
I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:2.5KVdc
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25℃/ 70% RH
EMC EMISSIONNote 6
ParameterStandardTest Level
ConductedBS EN/EN55032Class B
RadiatedBS EN/EN55032Class B
Voltage FlickerBS EN/EN61000-3-3-----
Harmonic Current----------
EMC IMMUNITYNote 6

BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 3, 6KV contact; criteria A
RadiatedBS EN/EN61000-4-3Level 3, 10V/m; criteria A
EFT / BurstBS EN/EN61000-4-4Level 3, 2KV; criteria A
SurgeBS EN/EN61000-4-5Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-FG ;criteria A
ConductedBS EN/EN61000-4-6Level 3, 10V; criteria A
Magnetic FieldBS EN/EN61000-4-8Level 4, 30A/m; criteria A
RAILWAY STANDARD
Compliance to BS EN/EN45545-2 for fire protection ; Meet BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC (except for 9~18Vin)

OTHERS

MTBF
1769.5K hrs min. Telcordia SR-332 (Bellcore) ; 214.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
32*125.2*102mm (W*H*D)
PACKING
510g; 28pcs/15.3Kg/1.23CUFT
Test conditions and notes7
  1. 1. All parameters NOT specially mentioned are measured at normal input (A:12Vdc , B:24Vdc) , rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltage. Please check the derating curve for more details.
  5. 5. 3 seconds max., please refer to peak loading curves.
  6. 6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  7. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

DDR-120A-12 Block Diagram
Block Diagram
DDR-120A-12 Derating Curve
Derating Curve
DDR-120A-12 Input Under-Voltage Protection
Input Under-Voltage Protection
DDR-120A-12 Inrush Current
Inrush Current
DDR-120A-12 Hold-up Time
Hold-up Time
DDR-120A-12 Efficiency vs Load & Vin Curve
Efficiency vs Load & Vin Curve
DDR-120A-12 D D R - 1 2 0 series
D D R - 1 2 0 series
DDR-120A-12 Mechanical Specification
Mechanical Specification

Typical applications

  • Bus,tram,metro or railway system
  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical
  • Wireless network
  • Telecom or datacom system

Downloads

FAQ

Can I use the DDR-120A-12 to power 12V embedded systems in a DIN rail control panel?

Yes. The DDR-120A-12 delivers 12V at up to 8.3A (99.6W), which suits many embedded controllers and single-board computers mounted in DIN rail enclosures. Its 9–18V DC input range is designed for battery-bus or low-voltage DC distribution systems commonly found in telecom and mobile equipment.

Is the DDR-120A-12 suitable for powering 12V sensors and I/O modules in industrial automation?

It can work well for sensor loops and I/O modules that run on 12V DC, provided total current draw stays within 8.3A. The 4KVdc input-to-output isolation helps protect sensitive measurement equipment from electrical noise in industrial environments.

Can I use this converter to turn a 12V battery bank into a regulated 12V rail?

The DDR-120A-12 accepts 9–18V DC input, so a nominal 12V battery source falls within range. It provides a regulated, isolated 12V output at up to 8.3A, which is useful for isolating sensitive loads from battery voltage fluctuations in mobile or off-grid installations. Note that output derating may be needed at low input voltage; check the derating curve.

Will the DDR-120A-12 operate reliably in an unheated outdoor cabinet during winter?

The DDR-120A-12 is rated for an operating temperature range of -40°C to +70°C (with derating at the upper end per the derating curve), so it can handle extreme cold. It is rated for 5–95% RH non-condensing, so the enclosure should protect it from direct moisture and condensation.

How does the DDR-120A-12 compare to other models in the DDR-120 series?

The DDR-120A sub-series accepts 9–18V DC input and comes in 12V (99.6W, 8.3A), 24V (100.8W, 4.2A), and 48V (100.8W, 2.1A) output variants. The DDR-120B accepts 16.8–33.6V input, the DDR-120C accepts 33.6–67.2V input, and the DDR-120D accepts 67.2–154V input, each available in 12V, 24V, and 48V outputs at 120W. All share the same 125.2 x 102.0 x 32.0 mm DIN rail form factor.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8441743966507, "variants" :[{ "context":"default", "variant_id": 45706924327211, "sku":"DDR-120A-12", "inventory_qty" : 2, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well DDR-120A-12 DC-DC Converter - 99.6W - 9~18V in 12V out 8.3A
Mean Well

Mean Well DDR-120A-12 DC-DC Converter - 99.6W - 9~18V in 12V out 8.3A

DDR-120A-12 is the 12V output model of this series: rated current 8.3A, rated power 99.6W, typical efficiency 88.5%.

DDR-120 series is a 120W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width (32mm), 2:1 wide input voltage, fanless design, -40~+70℃ wide operating temperature, 4KVdc I/O isolation, 150% peak load, adjustable output voltage and full protective functions. This series of models has various input options: 9~18V / 16.8~33.6V / 33.6~67.2V / 67.2~154V and various output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication system and other fields. Suitable applications include DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Width only 32mm
  • 2:1 wide input range
  • -40~+70℃ wide working temperature
  • 150% peak load capability
  • DC output adjustable
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
  • 4KVdc I/O isolation(Reinforced isolation)
  • Conformal coating
  • 3 years warranty

Typical applications

  • Bus,tram,metro or railway system
  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical
  • Wireless network
  • Telecom or datacom system

Model

  • 100W - 12V out - 9~18V in
  • 120W - 12V out - 16.8~33.6V in
  • 120W - 12V out - 33.6~67.2V in
  • 120W - 12V out - 67.2~154V in
  • 15W - 12V out - 9~36V in
  • 15W - 12V out - 18~75V in
  • 30W - 12V out - 9~36V in
  • 30W - 12V out - 18~75V in
  • 400.8W - 12V out - 16.8~33.6V in
  • 400.8W - 12V out - 33.6~67.2V in
  • 400.8W - 12V out - 67.2~154V in
  • 60W - 12V out - 9~36V in
  • 60W - 12V out - 18~75V in
View product