Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
MDD01L-05N is the ±5V output model of this series: rated power 1W, typical efficiency 78%.
MDS01-N and MDD01-N series are 1W isolated and unregulated module type medical grade DC-DC converter with SIP7 package. It features international standard pins, a high efficiency up to 84%, wide working temperature range -40~+95℃, 6KVDC I/P-O/P hi-ght isolation voltage, short circuit protection, etc. The models account for different input voltage 5V/12V/24V±10%, and various output voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for medical systems, ultra low leakage current or industrial control, telecommunication field, distributed power architecture, and so on.
Features
- SIP7 package with international standard pinout
- Operating temperature range -40 ~ +95℃
- Comply with IEC/UL62368-1 and LVD IEC60601-1
- Medical safety approved (1xMOPP/2xMOOP) according to IEC60601-1
- Low patient leakage current <2μA
- Protections: Short circuit (Continuous)
- 6KVDC hi-ght I/O isolation (Reinforced insulation)
- Low cost
- 3 years warranty
Specifications
INPUT
- INPUT VOLTAGE (RANGE)
- Normal 5V (4.5 ~ 5.5V)
- VOLTAGE RANGE
- 4.5 ~ 5.5Vdc
- INPUT CURRENT (NO LOAD)
- 30mA
- INPUT CURRENT (FULL LOAD)
- 245mA
- FILTER
- Internal capacitor
- PROTECTION
- Fuse recommended. 500mA Slow-Blow Type for all models
OUTPUT
- OUTPUT VOLTAGE
- ±5V
- OUTPUT CURRENT
- ±10 ~ 100mA
- EFFICIENCY(Typ.)
- 78%
- CAPACITOR LOAD(Max.)
- *330μF
- VOLTAGE ACCURACY
- ±5.0%
- RATED POWER
- 1W
- RIPPLE & NOISENote.2
- 100mVp-p
- LINE REGULATIONNote.3
- 1.2% for 1% input variation
- LOAD REGULATIONNote.4
- ±15% for 3.3Vo, 5Vo ; ±10% for others
- SWITCHING FREQUENCY(Typ.)
- 30KHz
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +95℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +105℃
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- 0.02% / ℃ (0 ~ 90℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- IEC62368-1 / UL62368-1, LVD IEC60601-1, EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:6KVDC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION LEVEL
- Primary-secondary: 1xMOPP / 2xMOOP when system input voltage is with 250VAC
- ISOLATION CAPACITANCE(Typ.)
- 10pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032, BS EN/EN55011 Class A/B with external components Radiated BS EN/EN55032, BS EN/EN55011 Class A/B with external components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 2, ±4KV contact, Level 3, ±8KV air Radiated Susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT/Bursts BS EN/EN61000-4-4 Level 1, 0.5KV / 5KHz Surge BS EN/EN61000-4-5 Level 1, 0.5KV Line to Ground Conducted BS EN/EN61000-4-6 Level 2, 3V(e.m.f.) Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m
OTHERS
- MTBF
- 15000Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 19.7*7.1*11.5mm (0.775*0.279*0.452 inch)
- CASE MATERIAL
- Non-Conductive black plastic (UL 94V-0 rated)
- PACKING
- 2.8g ; 24pcs/per tube, 2160pcs/90 tube/per carton
Test conditions and notes6
- 1.All parameters are specified at normal input(L:5Vdc, M:12Vdc, N:24Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.Patient leakage current(2μA max.) and reinforced isolation is based on a 250VAC, 50/60Hz system input voltage.
- 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Medical devices
- Medical oxygen monitor
- CT scanning
- Medical carts
- Oral care equipment
- Telecom / datacom system
- Wireless network
- Industrial control facility
Downloads
Datasheet1
FAQ
What type of product is the Mean Well MDD01L-05N?
The MDD01L-05N is a 1W SIP package DC-DC converter module from Mean Well. This specific model provides a ±5V output and is designed for compact embedded power applications where reinforced isolation and medical safety approvals are important.
What are the key electrical ratings of the MDD01L-05N?
This model is rated for 1W output power and provides a ±5V output. The product data lists an output current of ±10 to 100mA, and the MDD01L series uses a 5V input with a 4.5 to 5.5V input range.
Is the MDD01L-05N suitable for medical or safety-sensitive equipment?
Yes, this series is approved to LVD IEC60601-1 with 1xMOPP/2xMOOP support when the system input voltage is within 250VAC. It also features 6KVDC input-to-output isolation and a patient leakage current of 2 microamps max., which makes it relevant for applications with strict isolation and safety requirements.
What operating temperature range can the MDD01L-05N handle?
The MDD01L-05N is specified for operation from -40°C to +95°C, with load derating at higher temperatures per the derating curve. That wide range makes it a fit for industrial and embedded environments where ambient conditions may vary significantly.
What protection features does the MDD01L-05N include?
The module includes continuous short circuit protection for long-duration fault conditions, with automatic recovery. The specification also recommends a 500mA slow-blow fuse on the input.
How compact is the Mean Well MDD01L-05N?
The listed dimensions are 19.7 x 7.1 x 11.5 mm, and the product weight is 2.8 g. Its SIP7 package format is intended for space-constrained designs that need a small isolated DC-DC converter.
What certifications and compliance marks are listed for the MDD01L-05N?
The datasheet lists IEC62368-1 / UL62368-1, LVD IEC60601-1 and EAC TP TC 020/2011 approvals. This is useful for buyers evaluating regulatory fit for commercial or medical-related equipment.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other MDD01 Models
16 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.