Overview
SD-200C-48 is the 48V output model of this series: rated current 4.2A, rated power 201.6W, typical efficiency 86%.
Features
- 2:1 wide input range
- Protections: Short circuit / Overload / Over voltage / Over temperature
- 1500VAC I/O isolation
- Cooling by free air convection
- 100% full load burn-in test
- 24V and 48V input voltage design refer to LVD
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 4.2A
- CURRENT RANGE
- 0 ~ 4.2A
- RATED POWER
- 201.6W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- 43 ~ 53VDC
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 300ms, 50ms at full load
INPUT
- VOLTAGE RANGE
- 36 ~ 72VDC
- EFFICIENCY (Typ.)
- 86%
- DC CURRENT (Typ.)
- 5A/48V
- INRUSH CURRENT (Typ.)
- 45A/48VDC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Shut down o/p voltage, re-power on to recover
- OVER VOLTAGE
- 53 ~ 65V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1approved (for SD-200C-5/12/24 type only), EAC TP TC 004 approved, design refer to AS/NZS 62368.1
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,6,8, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 1919.7K hrs min. Telcordia SR-332 (Bellcore) ; 280.6K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 215*115*50mm (L*W*H)
- PACKING
- 1.1Kg; 12pcs/14.4Kg/0.9CUFT
Test conditions and notes5
- 1. All parameters NOT specially mentioned are measured at 24,48,96VDC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5.The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the SD-200C-48 to run a 48V industrial controller from a 36-72VDC bus system?
Yes, the listed specs show constant-voltage 48V output at up to 4.2A with a 36-72VDC input range. That makes it suitable when your source falls within 36-72VDC and the controller load stays within 201.6W.
Is this converter suitable for 48V automation sensors and I/O modules on mobile or embedded equipment?
It can fit 48V automation loads that need stable constant-voltage output rather than variable current drive. The rated output is 48V and 4.2A, so the combined load should remain within 201.6W.
Can the SD-200C-48 power a 48V HMI or communication panel in an industrial cabinet?
It is designed for constant-voltage output, so it can support 48V HMI or panel electronics when the total draw is within 4.2A. The 2:1 wide 36-72VDC input range also gives flexibility for systems operating across that span.
Is the SD-200C-48 appropriate for indoor or outdoor environments?
The specs list an operating temperature of -20°C to +60°C (refer to the derating curve), but no IP rating is stated. Without an IP rating, it should be treated as a converter for protected indoor enclosures rather than exposed outdoor use.
How does the SD-200C-48 compare with the other SD-200C models?
Within the SD-200C group, SD-200C-5 is listed at 200W, 5V, 40A; SD-200C-12 at 200.4W, 12V, 16.7A; SD-200C-24 at 201.6W, 24V, 8.4A; and SD-200C-48 at 201.6W, 48V, 4.2A. All are part of the same series family, but the output voltage, current, and wattage values differ by model.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SD-200C Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well SD-200C-5 DC-DC Converter - 200W - 36~72V in 5V out 40A | 200W | 5V | 40A | IP20 | View |
| Mean Well SD-200C-24 DC-DC Converter - 201.6W - 36~72V in 24V out 8.4A | 201.6W | 24V | 8.4A | IP20 | View |
| Mean Well SD-200C-12 DC-DC Converter - 200.4W - 36~72V in 12V out 16.7A | 200.4W | 12V | 16.7A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.