Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRPG-1000N3-12 is the 12V output model of this series: rated current 80A, rated power 960W, typical efficiency 91.5%.
HRPG-1000N3 series is a 1000W single output AC/DC with ultra-high peak power supply. This series operates for 90~264 VAC input voltage and offers models with different rated voltage ranging between 12 and 48 V that can satisfy the demands for all kinds of industrial equipments. Each model is cooled by the built-in fan with speed control, working for the temperature up to 70℃. Moreove, HRPG-1000N3 has various built-in functions such as auxiliary power, remote sense and remote on-off control, offering vast design flexibility for industrial application. It can provide 320% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 94%
- Withstand 300VAC surge input for 5 seconds
- Up to 320% peak power capability
- Protections: Short circuit / Overload / Over voltage / Over temperature
- For inductive and capacitive load
- Built-in cooling fan ON-OFF control
- Current sharing up to 4000W (3+1)
- Built-in DC OK / remote ON-OFF / remote sense functions
- Standby power 5V@0.3A
- No load power consumption<0.85W (Note.7)
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 80A
- CURRENT RANGE
- 0 ~ 80A
- RATED POWER
- 960W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 11 ~ 14V
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 91.5%
- AC CURRENT (Typ.)
- 8.5A/115VAC 5A/230VAC
- INRUSH CURRENT (Typ.)
- 25A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <1.2mA / 240VAC
PROTECTION
- OVERLOADNote.4
- Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover Output power > 320% rated then shut down o/p voltage, re-power on to recover for 12V Output power > 350% rated then shut down o/p voltage, re-power on to recover for 24V, 36V and 48V
- OVER VOLTAGE
- 14.5 ~ 16.5V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- CURRENT SHARING
- Up to 4000W or (3+1) units. Please refer to the function manual.
- REMOTE ON-OFF CONTROL
- Power ON : short; Power OFF : open. Please refer to the function manual.
- REMOTE SENSE
- Compensate voltage drop on the load wiring up to 0.5V. Please refer to the function manual.
- DC-OK SIGNAL
- The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V. Please refer to the function manual.
- 5V STANDBY
- 5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
- FAN CONTROL
- Fan on/off by NTC(RT50) or 30% load min.
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, CAN/CSA C22.2 No. 62368-1 , TUV BS EN/ EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) Class B Radiated BS EN/EN55032 (CISPR32) Class B Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55035, BS EN/EN61000-6-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-4-5 Level 4, 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 989.2K hrs min. Telcordia SR-332 (Bellcore) ; 130.6K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 218*105*61.5mm (L*W*H)
- PACKING
- 1.46Kg;8pcs/12.8Kg/1.58CUFT
Test conditions and notes9
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. After the output protection, restart the device about 30 seconds after the input disconnection interval.
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 7. No load power consumption<0.85W when RC+ & RC- (CN100 pin3,4) open.
- 8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Aging equipment
- RF application
Downloads
::specification::
FAQ
What are the main output specifications of the Mean Well HRPG-1000N3-12?
This model provides a 12V DC output with a rated current of 80A. The datasheet lists a 960W rated power, and the 12V model handles peak loads up to 320% of rated power before overload shutdown. It also includes built-in PFC and a typical efficiency of 91.5%.
What kinds of applications is the HRPG-1000N3-12 best suited for?
This power supply is aimed at industrial and high-reliability 12V systems that need substantial current capacity and strong transient handling. Its 80A output, 320% peak power capability, DC OK signal, and remote control features make it relevant for demanding B2B equipment and control platforms. It is best matched to equipment designed specifically for 12V DC input.
What makes the HRPG-1000N3-12 different from a more basic enclosed 12V power supply?
Compared with a more basic enclosed PSU, this model stands out with built-in PFC, a typical efficiency of 91.5%, and the ability to withstand a 300VAC surge input for 5 seconds. It also adds 320% peak power capability, current sharing support up to 4000W in a 3+1 setup, remote ON-OFF control, remote sense, and a built-in DC OK signal. Those features make it more suitable for higher-demand industrial use cases.
Can this model support systems that need higher total power or parallel power architecture?
Yes. The product data states current sharing up to 4000W in a 3+1 configuration, which makes it relevant for higher-power systems that use multiple supplies together. It also includes a built-in DC OK signal and remote ON-OFF control, which are useful features in monitored or managed power designs.
Is the HRPG-1000N3-12 suitable for demanding temperature conditions?
The listed operating temperature range is -40°C to 70°C, with output derating at higher ambient temperatures per the derating curve. The unit also uses a built-in cooling fan with ON-OFF control to help manage thermal performance. Buyers should still confirm that the surrounding enclosure and system conditions stay within the product's rated limits.
Is this a good choice for 12V loads with short-term peak demand?
It can be a strong fit when the equipment requires 12V DC and experiences brief peak demand, because this model is specifically described as having up to 320% peak power capability. That differentiates it from standard fixed-output supplies that are sized mainly around continuous load. The load still needs to be compatible with the unit's 12V output and 80A rated current.
What protection and support features are built into this power supply?
This model includes overload, over voltage, and over temperature protection. It also provides remote sense, a DC OK signal, remote ON-OFF control, and a 5V standby output rated at 0.3A. Those features help support monitored industrial systems where status signaling and control are important.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRPG-1000N3 Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRPG-1000N3-48 Power Supply 960W 48V, 320% peak power model 21A | 1008W | 21V | 21A | View |
| Mean Well HRPG-1000N3-36 Power Supply 960W 36V, 320% peak power model 28A | 1008W | 28V | 28A | View |
| Mean Well HRPG-1000N3-24 Power Supply 960W 24V, 320% peak power model 42A | 1008W | 24V | 42A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.








