💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HRPG-1000N3-24 Power Supply 960W 24V, 320% peak power model 42A

built-in active PFCPF > 0.95high efficiency up to 94%current sharing up to 4000Wup to 320% peak power capacity
SKU HRPG-1000N3-24
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

HRPG-1000N3-24 is the 24V output model of this series: rated current 42A, rated power 1008W, typical efficiency 93%.

HRPG-1000N3 series is a 1000W single output AC/DC with ultra-high peak power supply. This series operates for 90~264 VAC input voltage and offers models with different rated voltage ranging between 12 and 48 V that can satisfy the demands for all kinds of industrial equipments. Each model is cooled by the built-in fan with speed control, working for the temperature up to 70℃. Moreove, HRPG-1000N3 has various built-in functions such as auxiliary power, remote sense and remote on-off control, offering vast design flexibility for industrial application. It can provide 320% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 94%
  • Withstand 300VAC surge input for 5 seconds
  • Up to 320% peak power capability
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • For inductive and capacitive load
  • Built-in cooling fan ON-OFF control
  • Current sharing up to 4000W (3+1)
  • Built-in DC OK / remote ON-OFF / remote sense functions
  • Standby power 5V@0.3A
  • No load power consumption<0.85W (Note.7)
  • 5 years warranty

Specifications

HRPG-1000N3-24Specifications from the official datasheet (2026-04-03 edition)

OUTPUT

DC VOLTAGE
24V
RATED CURRENT
42A
CURRENT RANGE
0 ~ 42A
RATED POWER
1008W
RIPPLE & NOISE (max.)Note.2
200mVp-p
VOLTAGE ADJ. RANGE
22 ~ 28V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGE
90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
93%
AC CURRENT (Typ.)
8.5A/115VAC 5A/230VAC
INRUSH CURRENT (Typ.)
25A/115VAC 40A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC

PROTECTION

OVERLOADNote.4
Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover Output power > 320% rated then shut down o/p voltage, re-power on to recover for 12V Output power > 350% rated then shut down o/p voltage, re-power on to recover for 24V, 36V and 48V
OVER VOLTAGE
29 ~ 33V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

CURRENT SHARING
Up to 4000W or (3+1) units. Please refer to the function manual.
REMOTE ON-OFF CONTROL
Power ON : short; Power OFF : open. Please refer to the function manual.
REMOTE SENSE
Compensate voltage drop on the load wiring up to 0.5V. Please refer to the function manual.
DC-OK SIGNAL
The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V. Please refer to the function manual.
5V STANDBY
5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
FAN CONTROL
Fan on/off by NTC(RT50) or 30% load min.

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL62368-1, CAN/CSA C22.2 No. 62368-1 , TUV BS EN/ EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032 (CISPR32)Class B
RadiatedBS EN/EN55032 (CISPR32)Class B
Harmonic CurrentBS EN/EN61000-3-2Class A
Voltage FlickerBS EN/EN61000-3-3
EMC IMMUNITY

BS EN/EN55035, BS EN/EN61000-6-2

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 2, 4KV contact
RadiatedBS EN/EN61000-4-3Level 3
EFT / BurstBS EN/EN61000-4-4Level 3
SurgeBS EN/EN61000-4-5Level 4, 2KV/Line-Line 4KV/Line-Earth
ConductedBS EN/EN61000-4-6Level 3
Magnetic FieldBS EN/EN61000-4-8Level 4
Voltage Dips and InterruptionsBS EN/EN61000-4-11>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

OTHERS

MTBF
989.2K hrs min. Telcordia SR-332 (Bellcore) ; 130.6K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
218*105*61.5mm (L*W*H)
PACKING
1.46Kg;8pcs/12.8Kg/1.58CUFT
Test conditions and notes9
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. After the output protection, restart the device about 30 seconds after the input disconnection interval.
  5. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  7. 7. No load power consumption<0.85W when RC+ & RC- (CN100 pin3,4) open.
  8. 8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  9. 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRPG-1000N3-24 Block Diagram
Block Diagram
HRPG-1000N3-24 Derating Curve
Derating Curve
HRPG-1000N3-24 1000W Ultra-High Peak Power Supply
1000W Ultra-High Peak Power Supply
HRPG-1000N3-24 Duty(%)
Duty(%)
HRPG-1000N3-24 Function Manual
Function Manual
HRPG-1000N3-24 1000W Ultra-High Peak Power Supply
1000W Ultra-High Peak Power Supply
HRPG-1000N3-24 4.Current Sharing
4.Current Sharing
HRPG-1000N3-24 Mechanical Specification
Mechanical Specification

Typical applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Aging equipment
  • RF application

Downloads

::specification::

FAQ

What makes the Mean Well HRPG-1000N3-24 different from a standard 24V 1000W power supply?

This model is designed for demanding loads that may need very high short-term surge capacity. It delivers 24V DC with a 1008W rated output, and its standout feature is ultra-high peak power capability: the output only shuts down above 350% of rated power, within the duty limits in the function manual, which distinguishes it from standard enclosed power supplies in the same voltage class.

What output does the HRPG-1000N3-24 provide?

The HRPG-1000N3-24 is a 24V enclosed AC-DC power supply with a 1008W rated output and 42A rated current. It is intended for systems that need a high-power 24V DC supply from a universal AC input range.

Is the HRPG-1000N3-24 suitable for industrial equipment with heavy startup or transient loads?

Yes. This model is positioned for higher-reliability industrial use and supports ultra-high peak power (overload shutdown only above 350% of rated power for short peaks), making it a strong fit where temporary load surges are a concern. It also includes protection functions for overload, over voltage, and over temperature.

Can this power supply be used in systems that need monitoring or remote control features?

Yes. The HRPG-1000N3-24 includes a built-in DC OK signal and remote ON-OFF control, which can be useful in equipment that needs power-status monitoring or controlled power management. It also includes remote sense and a 5V standby output rated at 0.3A.

How does the HRPG-1000N3-24 perform in demanding electrical environments?

This model includes built-in PFC with power factor greater than 0.95 at 230VAC and offers a typical efficiency of 93%. It can also withstand a 300VAC surge input for 5 seconds, which supports use in tougher industrial power environments.

Can the HRPG-1000N3-24 be scaled for higher power systems?

Yes. Mean Well specifies current sharing up to 4000W in a 3+1 configuration, so this model can support higher-power system designs that need parallel power capacity. That makes it relevant for larger 24V DC platforms where a single unit is not enough.

What operating conditions and warranty does this model offer?

The HRPG-1000N3-24 is specified for operation from -40°C to 70°C, with derating at higher ambient temperatures per the derating curve, which is a wide range for industrial applications. It also has no-load power consumption below 0.85W; the datasheet does not state a warranty period.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8791113335083, "variants" :[{ "context":"default", "variant_id": 47182711718187, "sku":"HRPG-1000N3-24", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRPG-1000N3-24 Power Supply 960W 24V, 320% peak power model 42A
Mean Well

Mean Well HRPG-1000N3-24 Power Supply 960W 24V, 320% peak power model 42A

HRPG-1000N3-24 is the 24V output model of this series: rated current 42A, rated power 1008W, typical efficiency 93%.

HRPG-1000N3 series is a 1000W single output AC/DC with ultra-high peak power supply. This series operates for 90~264 VAC input voltage and offers models with different rated voltage ranging between 12 and 48 V that can satisfy the demands for all kinds of industrial equipments. Each model is cooled by the built-in fan with speed control, working for the temperature up to 70℃. Moreove, HRPG-1000N3 has various built-in functions such as auxiliary power, remote sense and remote on-off control, offering vast design flexibility for industrial application. It can provide 320% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.95
  • High efficiency up to 94%
  • Withstand 300VAC surge input for 5 seconds
  • Up to 320% peak power capability
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • For inductive and capacitive load
  • Built-in cooling fan ON-OFF control
  • Current sharing up to 4000W (3+1)
  • Built-in DC OK / remote ON-OFF / remote sense functions
  • Standby power 5V@0.3A
  • No load power consumption<0.85W (Note.7)
  • 5 years warranty

Typical applications

  • Factory control or automation apparatus
  • Test and measurement instrument
  • Laser related machine
  • Aging equipment
  • RF application
View product