Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRPG-1000N3-24 is the 24V output model of this series: rated current 42A, rated power 1008W, typical efficiency 93%.
HRPG-1000N3 series is a 1000W single output AC/DC with ultra-high peak power supply. This series operates for 90~264 VAC input voltage and offers models with different rated voltage ranging between 12 and 48 V that can satisfy the demands for all kinds of industrial equipments. Each model is cooled by the built-in fan with speed control, working for the temperature up to 70℃. Moreove, HRPG-1000N3 has various built-in functions such as auxiliary power, remote sense and remote on-off control, offering vast design flexibility for industrial application. It can provide 320% short-duration peak power for motor applications and electromechanical loads requiring much higher power during start-up.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 94%
- Withstand 300VAC surge input for 5 seconds
- Up to 320% peak power capability
- Protections: Short circuit / Overload / Over voltage / Over temperature
- For inductive and capacitive load
- Built-in cooling fan ON-OFF control
- Current sharing up to 4000W (3+1)
- Built-in DC OK / remote ON-OFF / remote sense functions
- Standby power 5V@0.3A
- No load power consumption<0.85W (Note.7)
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 42A
- CURRENT RANGE
- 0 ~ 42A
- RATED POWER
- 1008W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- 22 ~ 28V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2000ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC(300VAC for 5 sec.) 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 93%
- AC CURRENT (Typ.)
- 8.5A/115VAC 5A/230VAC
- INRUSH CURRENT (Typ.)
- 25A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <1.2mA / 240VAC
PROTECTION
- OVERLOADNote.4
- Output power >105% rated for more than 5 seconds then shut down o/p voltage, re-power on to recover Output power > 320% rated then shut down o/p voltage, re-power on to recover for 12V Output power > 350% rated then shut down o/p voltage, re-power on to recover for 24V, 36V and 48V
- OVER VOLTAGE
- 29 ~ 33V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- CURRENT SHARING
- Up to 4000W or (3+1) units. Please refer to the function manual.
- REMOTE ON-OFF CONTROL
- Power ON : short; Power OFF : open. Please refer to the function manual.
- REMOTE SENSE
- Compensate voltage drop on the load wiring up to 0.5V. Please refer to the function manual.
- DC-OK SIGNAL
- The TTL signal out, PSU turn on = 3.3 ~ 5.6V ; PSU turn off = 0 ~ 1V. Please refer to the function manual.
- 5V STANDBY
- 5VSB : 5V@0.3A ; tolerance±5%, ripple : 50mVp-p(max.)
- FAN CONTROL
- Fan on/off by NTC(RT50) or 30% load min.
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, CAN/CSA C22.2 No. 62368-1 , TUV BS EN/ EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) Class B Radiated BS EN/EN55032 (CISPR32) Class B Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55035, BS EN/EN61000-6-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-4-5 Level 4, 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 989.2K hrs min. Telcordia SR-332 (Bellcore) ; 130.6K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 218*105*61.5mm (L*W*H)
- PACKING
- 1.46Kg;8pcs/12.8Kg/1.58CUFT
Test conditions and notes9
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. After the output protection, restart the device about 30 seconds after the input disconnection interval.
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 7. No load power consumption<0.85W when RC+ & RC- (CN100 pin3,4) open.
- 8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*700mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Aging equipment
- RF application
Downloads
::specification::
FAQ
What makes the Mean Well HRPG-1000N3-24 different from a standard 24V 1000W power supply?
This model is designed for demanding loads that may need very high short-term surge capacity. It delivers 24V DC with a 1008W rated output, and its standout feature is ultra-high peak power capability: the output only shuts down above 350% of rated power, within the duty limits in the function manual, which distinguishes it from standard enclosed power supplies in the same voltage class.
What output does the HRPG-1000N3-24 provide?
The HRPG-1000N3-24 is a 24V enclosed AC-DC power supply with a 1008W rated output and 42A rated current. It is intended for systems that need a high-power 24V DC supply from a universal AC input range.
Is the HRPG-1000N3-24 suitable for industrial equipment with heavy startup or transient loads?
Yes. This model is positioned for higher-reliability industrial use and supports ultra-high peak power (overload shutdown only above 350% of rated power for short peaks), making it a strong fit where temporary load surges are a concern. It also includes protection functions for overload, over voltage, and over temperature.
Can this power supply be used in systems that need monitoring or remote control features?
Yes. The HRPG-1000N3-24 includes a built-in DC OK signal and remote ON-OFF control, which can be useful in equipment that needs power-status monitoring or controlled power management. It also includes remote sense and a 5V standby output rated at 0.3A.
How does the HRPG-1000N3-24 perform in demanding electrical environments?
This model includes built-in PFC with power factor greater than 0.95 at 230VAC and offers a typical efficiency of 93%. It can also withstand a 300VAC surge input for 5 seconds, which supports use in tougher industrial power environments.
Can the HRPG-1000N3-24 be scaled for higher power systems?
Yes. Mean Well specifies current sharing up to 4000W in a 3+1 configuration, so this model can support higher-power system designs that need parallel power capacity. That makes it relevant for larger 24V DC platforms where a single unit is not enough.
What operating conditions and warranty does this model offer?
The HRPG-1000N3-24 is specified for operation from -40°C to 70°C, with derating at higher ambient temperatures per the derating curve, which is a wide range for industrial applications. It also has no-load power consumption below 0.85W; the datasheet does not state a warranty period.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HRPG-1000N3 Models
3 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HRPG-1000N3-48 Power Supply 960W 48V, 320% peak power model 21A | 1008W | 21V | 21A | View |
| Mean Well HRPG-1000N3-36 Power Supply 960W 36V, 320% peak power model 28A | 1008W | 28V | 28A | View |
| Mean Well HRPG-1000N3-12 Power Supply 960W 12V, 320% peak power model 80A | 960W | 12V | 80A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.