LPV-60-48 is the 48V output model of this series: rated current 1.25A, rated power 60W, typical efficiency 86%.
Features
- Constant voltage design
- Universal AC input / Full range
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Over load / Over voltage
- Cooling by free air convection
- Fully encapsulated with IP67 level (Note.7)
- Fully isolated plastic case
- Class Ⅱ power unit, no FG
- Class 2 power unit
- Pass LPS
- Display devices for decorative & advertising accessories (Note.11)
- General-purpose electronics operated in dusty or damp environments
- 100% full load burn-in test
- Low cost, high reliability
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 1.25A
- CURRENT RANGE
- 0 ~ 1.25A
- RATED POWER
- 60W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE TOLERANCENote.3
- ±5.0%
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIMENote.6
- 500ms, 20ms / 230VAC 500ms, 20ms / 115VAC at full load(for 5~36V) ; 500ms, 30ms / 230VAC 500ms, 30ms / 115VAC at full load(for 48V)
- HOLD UP TIME (Typ.)
- 50ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 86%
- AC CURRENT (Typ.)
- 1.2A/115VAC 1A/230VAC
- INRUSH CURRENT(Typ.)
- COLD START 60A(twidth=525μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 3 units (circuit breaker of type B) / 6 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- 0.25mA / 240VAC
PROTECTION
- OVER LOAD
- 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 55.2 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL879(except for LPV-60-5), UL1310(except for LPV-60-5), CSA C22.2 No. 207-M89(except for LPV-60-5, LPV-60-48), CAN/CSA C22.2 No. 223-M91(except for LPV-60-5,LPV-60-48), BIS IS15885(Note 12), EAC TP TC 004, IP67, IEC62368-1 , BS EN/EN62368-1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC
- ISOLATION RESISTANCE
- I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class A, BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 5188.4K hrs min. Telcordia SR-332 (Bellcore) ; 732.1Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 162.5*42.5*32mm (L*W*H)
- PACKING
- 0.4Kg; 32pcs/13.8Kg/0.66CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 5. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 7. Suitable for indoor use or outdoor use without direct sunlight exposure. Please avoid immerse in the water over 30 minute.
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 9. Products sourced from the Americas regions may not have the TUV/BIS/CCC logo. Please contact your MEAN WELL sales for more information.
- 10. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 11. This product is not intended for LED lighting luminaire applications in the EU and China.(In the EU and China the LPF/NPF/XLG/XLC/XLN series are recommended.)
- 12. Products sourced from the China regions may not have the BIS logo, please contact your MEAN WELL sales for more information.
Technical drawings
Downloads
FAQ
What types of LED lighting can the LPV-60-48 power?
The LPV-60-48 is suited for 48V LED strip systems, architectural lighting, and commercial signage that operates at 48V. At 60W maximum output, it can drive a 48V LED load up to 60W — check your strip's rated power per meter to calculate the maximum run length. Its IP67 rating makes it a practical choice for outdoor signage or covered exterior installations.
How much LED strip can I run from the LPV-60-48?
The LPV-60-48 delivers up to 60W at 48V. To find the maximum strip length, divide 60W by your strip's rated wattage per meter — for example, a 10W/m strip would allow up to 6 meters. Always check your strip's rated power per meter, as actual limits depend on that specification.
Is the LPV-60-48 suitable for outdoor or wet environments?
Yes, within limits. The LPV-60-48 carries an IP67 rating, meaning it is dust-tight and protected against temporary immersion in water (the sheet advises avoiding immersion over 30 minutes). It operates across -30°C to +70°C with derating at higher temperatures and is rated for outdoor use without direct sunlight exposure, making it appropriate for outdoor LED signage and lighting in damp locations shielded from direct sun.
What input voltage range does the LPV-60-48 accept?
The LPV-60-48 accepts a universal input range of 90–264VAC, so it works with standard electrical supplies in North America, Europe, and most other regions without any manual switching; derating may be needed at low input voltage. This makes it convenient for projects that may be deployed across different countries or buildings with variable mains voltage.
What certifications does the LPV-60-48 hold?
The LPV-60-48 is approved to UL879 and UL1310, IEC62368-1 and BS EN/EN62368-1, EAC TP TC 004 and BIS IS15885; the CSA approvals listed for other LPV-60 models exclude the 48V version. UL covers the United States, EAC the Eurasian Economic Union, and IEC/EN62368-1 is the international and European safety standard. It also carries a 2-year warranty from Mean Well.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other LPV-60 Models
5 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well LPV-60-24 LED Driver — 60W 24V 2.5A IP67 Waterproof | 60W | 24V | 2.5A | IP67 | View |
| Mean Well LPV-60-12 LED Driver — 60W 12V 5A IP67 Waterproof | 60W | 12V | 5A | IP67 | View |
| Mean Well LPV-60-5 LED Driver — 40W 5V 8A IP67 Waterproof | 40W | 5V | 8A | IP67 | View |
| Mean Well LPV-60-36 LED Driver — 60W 36V 1.67A IP67 Waterproof | 60W | 36V | 1.67A | IP67 | View |
| Mean Well LPV-60-15 LED Driver — 60W 15V 4A IP67 Waterproof | 60W | 15V | 4A | IP67 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.