Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
MDD01L-12 is the ±12V output model of this series: rated power 1W, typical efficiency 77%.
MDS01 and MDD01 series are 1W isolated and unregulated module type medical grade DC-DC converter with SIP7 package. It features international standard pins, a high efficiency up to 83%, wide working temperature range -40~+85℃, 6KVDC or 4.2KVAC I/P-O/P high isolation voltage, short circuit protection, etc. The models account for different input voltage 5V/12V/24V±10%, and various output voltage, 3.3V/ 5V/ 12 V/15V for single output and ±5V /±9 V/±12V/±15V for dual outputs, which are suitable for medical systems , ultra low leakage current.
Features
- SIP7 package with international standard pinout
- Operating temperature range -40 ~ +85℃
- Medical safety approved (1xMOPP/2xMOOP) according to ANSI/AAMI ES60601-1
- Low patient leakage current <2μA
- Protection: Short circuit(3 second max.)
- 6KVDC or 4.2KVAC hight I/O isolation (Reinforced isolation)
- Low cost
- 3 years warranty
Specifications
INPUT
- INPUT VOLTAGE (RANGE)
- Normal 5V (4.5 ~ 5.5V)
- VOLTAGE RANGE
- 4.5 ~ 5.5Vdc
- INPUT CURRENT (NO LOAD)
- 40mA
- INPUT CURRENT (FULL LOAD)
- 265mA
- SURGE VOLTAGE (100ms max.)
- 5Vin models : 9Vdc 12Vin models : 18Vdc 24Vin models : 30Vdc
- FILTER
- Internal capacitor
- PROTECTION
- Fuse recommended. 500mA Slow-Blow Type for all models
OUTPUT
- OUTPUT VOLTAGE
- ±12V
- OUTPUT CURRENT
- ±5 ~ 42mA
- EFFICIENCY (TYP.)
- 77%
- CAPACITOR LOAD (MAX.)* For each output
- *220μF
- VOLTAGE ACCURACY
- ±5.0%
- RATED POWER
- 1W
- RIPPLE & NOISENote.2
- 75mVp-p
- LINE REGULATIONNote.3
- 1.2% for 1% input variation
- LOAD REGULATIONNote.4
- ±10%
- SWITCHING FREQUENCY (Typ.)
- 100KHz
PROTECTION
- SHORT CIRCUIT
- 3 second max.
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- 0.02% / ℃ (0 ~ 85℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL60601-1, EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:6KVDC or 4.2KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION LEVEL
- Primary-secondary: 1xMOPP / 2xMOOP when system input voltage is with 250VAC, 50/60Hz
- ISOLATION CAPACITANCE (Typ.)
- 5pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55011(CISPR11) Class B Radiated BS EN/EN55011(CISPR11) Class B - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 2, ±8KV contact
OTHERS
- MTBF
- 3500Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 19.5*9.8*12.5mm (0.77*0.386*0.492 inch)
- CASE MATERIAL
- Non-Conductive black plastic (UL 94V-0 rated)
- PACKING
- 4.2g ; 25pcs/per tube, 3000pcs/120 tube/per carton
Test conditions and notes6
- 1.All parameters are specified at normal input(L:5Vdc, M:12Vdc, N:24Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.Patient leakage current(2μA max.) and reinforced isolation is based on a 250VAC, 50/60Hz system input voltage.
- 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Medical devices
- Medical oxygen monitor
- CT scanning
- Medical carts
- Oral care equipment
Downloads
Certificates4
Test reports1
FAQ
Can I use the MDD01L-12 in a compact industrial control board that needs ±12V rails from a 5V DC source?
This converter is built for a 4.5~5.5VDC input and provides a fixed ±12V output. Its 1W rating, up to 42mA per output, and 19.5 × 9.8 × 12.5 mm package fit low-power industrial control and signal-conditioning circuits where ±12V is required.
Is the MDD01L-12 suitable for embedded analog interface circuits that require isolated ±12V power?
It can fit embedded analog sections that need a ±12V output in a low-power design. The unit is rated for 1W with up to 42mA per output, so it is best matched to light-load analog or interface stages rather than higher-current subsystems.
Can this converter be used in automation monitoring equipment with limited board space?
Yes, the small 19.5 × 9.8 × 12.5 mm body and 0.0042 kg weight make it practical for dense automation electronics. The 1W design and fixed ±12V output suit low-power monitoring, sensing, or interface sections that operate from a 4.5~5.5VDC input.
Is the MDD01L-12 meant for outdoor or harsh-environment use?
The listed operating temperature is -40°C to +85°C (with load derating at higher temperatures, see the derating curve), which supports use across a wide temperature range. No IP rating is provided in the specs, so it is better treated as a board-level part for protected indoor or enclosed equipment rather than exposed outdoor use.
How does the MDD01L-12 compare with other MDD01L series options?
Within the same 1W MDD01L family (5V nominal input), the sibling outputs are ±5V at up to 100mA for MDD01L-05, ±9V at up to 56mA for MDD01L-09, and ±15V at up to 34mA for MDD01L-15. The MDD01L-12 itself is the ±12V version rated at up to 42mA per output.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other MDD01 Models
17 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.