Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NID65-12 is the 12V output model of this series: rated power 58.8W, typical efficiency 96%.
Features
- Economical open frame design
- Wide input range
- High efficiency up to 97%
- Remote ON / OFF control
- Compact size 2.0"×1.024"× 0.433"(SIP package)
- Protections: Short circuit / Overload / Over voltage
- -30~+85℃ wide working temperature
- Cooling by free air convection
- Comply to BS EN/EN55032 ClassA without additional components
- Trimming output (optional)
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- CURRENT RANGE
- 0 ~ 4.9A
- RATED POWER
- 58.8W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±0.5%
- VOLTAGE TOLERANCE
- ±2.0%
- SWITCHING FREQUENCY (Typ.)
- 200KHz
- EXTERNAL CAPACITANCE LOAD (max.)
- 68uf/25V low ESR
INPUT
- VOLTAGE RANGE
- 20 ~ 53VDC
- NORMAL VOLTAGE
- 24VDC (or 48VDC)
- EFFICIENCY (Typ.) 24Vin
- 96%
- EFFICIENCY (Typ.) 48Vin
- 95%
- DC CURRENT Full load
- 2700mA/24VDC
- DC CURRENT No load
- 30mA
PROTECTION
- PROTECTION
- Fuse recommended (5A)
- OVERLOAD (Typ.)
- 120 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 15.6~ 18V Protection type : Shut off o/p voltage, clamp by TVS diode
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
FUNCTION
- REMOTE CONTROL
- Power on : 1.2VDC < R.C ~ com < 12VDC or open circuit ; power off : R.C ~ com < 0.4VDC or short circuit (PIN5,6 & PIN11)
ENVIRONMENT
- SAFETY STANDARDS
- EAC TP TC 004 approved
- WORKING TEMP.
- -30 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 85% RH non-condensing
- STORAGE TEMP.
- -30 ~ +105℃
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 55℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARD
- BS EN/EN62368-1(LVD)
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A without external components,Class B with external components Radiated BS EN/EN55032 Class A without external components,Class B with external components - EMC IMMUNITY
-
BS EN/EN55035
Parameter Standard Test Level Radiated BS EN/EN61000-4-3 Level 2, 3V/m; criteria A EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV; criteria A Surge BS EN/EN61000-4-5 Level 2, 1KV/Line-Line,criteria A Conducted BS EN/EN61000-4-6 Level 2, 3V; criteria A
OTHERS
- MTBF
- 16602.6K hrs min. Telcordia SR-332 (Bellcore) ; 890.7K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*26*11mm or 2.0"*1.024"*0.433" inch (L*W*H)
- WEIGHT
- 19g;280psc/6.32Kg/0.94CUFT
Test conditions and notes4
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH Ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
Technical drawings
Downloads
Certificates3
Test reports1
FAQ
Can I use the NID65-12 for a 12V industrial control device?
Yes, if the equipment requires a constant-voltage 12V output and draws no more than 4.9A or 58.8W. This model accepts 20-53VDC input and is intended for regulated 12V loads.
Is the NID65-12 suitable for 12V embedded or edge-computing hardware in a wider-input system?
It can be used where the source is within 20-53VDC and the load needs a stable 12V constant-voltage output. The available output is capped at 4.9A and 58.8W, so the total draw of the embedded hardware must stay within that limit.
Can this converter power 12V automation accessories or low-power actuators?
It is appropriate for 12V automation loads that need constant voltage and stay within 4.9A output current. The total output capacity is 58.8W, so it fits lighter-duty 12V accessories rather than higher-power 12V loads.
Is the NID65-12 appropriate for harsh temperature environments?
Its operating temperature range is -30°C to +85°C, which supports use across a wide temperature span. No IP rating is listed in the provided specs, so suitability for exposed outdoor or washdown environments is not established here.
How does the NID65-12 compare with the other NID65 models?
The NID65-12 provides 12V at 4.9A for 58.8W with a 20-53VDC input range. In the same series, the NID65-15 is 15V, 4.3A, 64.5W; the NID65-24 is 24V, 2.7A, 64.8W; and the NID65-5 is 5V, 6.5A, 32.5W.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NID65 Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well NID65-5 DC-DC Converter - 32.5W - 10.5~53V in 5V out 6.5A | 32.5W | 5V | 6.5A | IP20 | View |
| Mean Well NID65-24 DC-DC Converter - 64.8W - 30~53V in 24V out 2.7A | 64.8W | 24V | 2.7A | IP20 | View |
| Mean Well NID65-15 DC-DC Converter - 64.5W - 20~53V in 15V out 4.3A | 64.5W | 15V | 4.3A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.