Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NID65-15 is the 15V output model of this series: rated power 64.5W, typical efficiency 97%.
Features
- Economical open frame design
- Wide input range
- High efficiency up to 97%
- Remote ON / OFF control
- Compact size 2.0"×1.024"× 0.433"(SIP package)
- Protections: Short circuit / Overload / Over voltage
- -30~+85℃ wide working temperature
- Cooling by free air convection
- Comply to BS EN/EN55032 ClassA without additional components
- Trimming output (optional)
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- CURRENT RANGE
- 0 ~ 4.3A
- RATED POWER
- 64.5W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±0.5%
- VOLTAGE TOLERANCE
- ±2.0%
- SWITCHING FREQUENCY (Typ.)
- 200KHz
- EXTERNAL CAPACITANCE LOAD (max.)
- 47uf/50V low ESR
INPUT
- VOLTAGE RANGE
- 20 ~ 53VDC
- NORMAL VOLTAGE
- 24VDC (or 48VDC)
- EFFICIENCY (Typ.) 24Vin
- 97%
- EFFICIENCY (Typ.) 48Vin
- 95%
- DC CURRENT Full load
- 3000mA/24VDC
- DC CURRENT No load
- 30mA
PROTECTION
- PROTECTION
- Fuse recommended (5A)
- OVERLOAD (Typ.)
- 120 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 17.5~ 21V Protection type : Shut off o/p voltage, clamp by TVS diode
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
FUNCTION
- REMOTE CONTROL
- Power on : 1.2VDC < R.C ~ com < 12VDC or open circuit ; power off : R.C ~ com < 0.4VDC or short circuit (PIN5,6 & PIN11)
ENVIRONMENT
- SAFETY STANDARDS
- EAC TP TC 004 approved
- WORKING TEMP.
- -30 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 85% RH non-condensing
- STORAGE TEMP.
- -30 ~ +105℃
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 55℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1 cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARD
- BS EN/EN62368-1(LVD)
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A without external components,Class B with external components Radiated BS EN/EN55032 Class A without external components,Class B with external components - EMC IMMUNITY
-
BS EN/EN55035
Parameter Standard Test Level Radiated BS EN/EN61000-4-3 Level 2, 3V/m; criteria A EFT / Burst BS EN/EN61000-4-4 Level 2, 1KV; criteria A Surge BS EN/EN61000-4-5 Level 2, 1KV/Line-Line,criteria A Conducted BS EN/EN61000-4-6 Level 2, 3V; criteria A
OTHERS
- MTBF
- 16602.6K hrs min. Telcordia SR-332 (Bellcore) ; 890.7K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*26*11mm or 2.0"*1.024"*0.433" inch (L*W*H)
- WEIGHT
- 19g;280psc/6.32Kg/0.94CUFT
Test conditions and notes4
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH Ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
Technical drawings
Downloads
Certificates3
Test reports1
FAQ
Can I use the NID65-15 with 15V industrial sensors or instrumentation modules?
Yes, if the load requires a constant-voltage 15V output and stays within 4.3A or 64.5W. This converter is designed for regulated 15V applications with a 20-53VDC input range.
Is the NID65-15 a fit for 15V automation electronics in a compact enclosure?
It can fit compact assemblies because the body is 50.8 × 26.0 × 11.0 mm and weighs 0.019 kg. Electrically, the load still needs to match a 15V constant-voltage output and remain at or below 4.3A and 64.5W.
Can this model support 15V embedded control boards from a variable input source?
It is suitable when the available source is within 20-53VDC and the board expects a regulated 15V output. The supported load envelope is up to 4.3A and 64.5W.
Will the NID65-15 work in indoor industrial areas with temperature swings?
The specified operating range is -30°C to +85°C, so the temperature tolerance is broad. No IP rating is provided in the specs, so exposed outdoor suitability cannot be confirmed from this product data alone.
What is the difference between the NID65-15 and the other NID65 versions?
The NID65-15 outputs 15V at 4.3A for 64.5W and accepts 20-53VDC input. Other versions are NID65-12 at 12V, 4.9A, 58.8W; NID65-24 at 24V, 2.7A, 64.8W; and NID65-5 at 5V, 6.5A, 32.5W.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NID65 Models
3 other models| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well NID65-5 DC-DC Converter - 32.5W - 10.5~53V in 5V out 6.5A | 32.5W | 5V | 6.5A | IP20 | View |
| Mean Well NID65-24 DC-DC Converter - 64.8W - 30~53V in 24V out 2.7A | 64.8W | 24V | 2.7A | IP20 | View |
| Mean Well NID65-12 DC-DC Converter - 58.8W - 20~53V in 12V out 4.9A | 58.8W | 12V | 4.9A | IP20 | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.