💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well PLC-30-15 Power Supply 30W 15V - PFC 2A

screw terminalfully isolated plastic casesuitable for signage applications
SKU PLC-30-15
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

PLC-30-15 is the 15V output model of this series: rated current 2A, rated power 30W, typical efficiency 83.5%.

Features

  • Universal AC input / Full range
  • Adjustable output voltage and current level
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Fully isolated plastic case with terminal block style of I/O
  • Built-in active PFC function, comply with BS EN/EN61000-3-2 class C (Pin≧25W)
  • Class Ⅱ power unit, no FG
  • Class 2 power unit
  • 100% full load burn-in test
  • High reliability

Specifications

PLC-30-15Specifications from the official datasheet (2026-02-09 edition)

OUTPUT

DC VOLTAGE
15V
CONSTANT CURRENT REGIONNote.6
10.5 ~ 15V
RATED CURRENT
2A
CURRENT RANGE
0 ~ 2A
RATED POWER
30W
RIPPLE & NOISE (max.)Note.2
2.6Vp-p
VOLTAGE ADJ. RANGENote.5
14.5 ~ 16.5V
CURRENT ADJ. RANGENote.5
1.5 ~ 2.06A
VOLTAGE TOLERANCENote.3
±10%
LINE REGULATION
±3.0%
LOAD REGULATION
±5.0%
SETUP TIME
500ms / 230VAC 3000ms / 115VAC at full load

INPUT

VOLTAGE RANGENote.4
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.95/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading≧70% at 115VAC/230VAC input
EFFICIENCY (Typ.)
83.5%
AC CURRENT (Typ.)
0.4A/115VAC 0.2A/230VAC
INRUSH CURRENT (Typ.)
COLD START 35A(twidth=25μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER
64 units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.5mA / 240VAC

PROTECTION

OVER CURRENT
100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE
17 ~ 22V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.
-30 ~ +50℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.06%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL1310, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (Pin≧25W), Class D (>70% load) ; BS EN/EN61000-3-3,EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024, BS EN/EN61547, light industry level, EAC TP TC 020

OTHERS

MTBF
4293.1K hrs min. Telcordia SR-332 (Bellcore) 625.5Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
160*46*30mm (L*W*H)
PACKING
0.2Kg; 70pcs/15Kg/0.96CUFT

Certifications & ratings

Marked features
FC
Test conditions and notes12
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
  5. 5. Output voltage can be adjusted through the SVR1 on the PCB; limit of output constant current level can be adjusted through the SVR2 on the PCB.
  6. 6. Please refer to "DRIVING METHODS OF LED MODULE".
  7. 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  8. 8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
  9. 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  11. 11. PLC-30-9 is used for any light source that exempt from the ErP-Directive (EU) 2019/2020 requirement, for example this model could be use for signalling products (including, but not limited to road-, railway-, marineorair traffic-signalling , traffic control or airfield lamps).
  12. 12. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)

Technical drawings

PLC-30-15 Mechanical Specification
Mechanical Specification
PLC-30-15 Block Diagram
Block Diagram
PLC-30-15 Derating Curve
Derating Curve
PLC-30-15 Power Factor Characteristic
Power Factor Characteristic
PLC-30-15 EFFICIENCY vs LOAD (48V Model)
EFFICIENCY vs LOAD (48V Model)

Typical applications

  • Suitable for LED lighting and moving sign applications (Note.2)
  • Compliance to worldwide safety regulations for lighting
  • 2 years warranty

Downloads

FAQ

What are the main output ratings of the Mean Well PLC-30-15?

The PLC-30-15 is a 30W power supply with a 15V DC output and a rated current of 2.0A. This model also includes adjustable output voltage and current level, which is useful when a design needs some setup flexibility within the unit's supported operating range.

What kinds of applications is the PLC-30-15 typically suited for?

This model is generally suited to equipment that needs a regulated 15V DC supply up to 30W. Its constant-voltage output with built-in constant-current limiting makes it a practical fit for industrial, commercial, and lighting-related systems where a stable 15V source is required.

Does the Mean Well PLC-30-15 include power factor correction?

Yes. The PLC-30-15 has built-in PFC, with a typical power factor of PF>0.95 at 115VAC and PF>0.9 at 230VAC at full load according to the datasheet. That is a useful differentiator for buyers looking for improved input-side power quality in professional or commercial applications.

What operating temperature range is specified for the PLC-30-15?

The specified operating temperature range is -30°C to 50°C. This gives the PLC-30-15 a useful span for demanding indoor equipment environments, provided the rest of the system is designed to stay within those limits.

Is the PLC-30-15 compatible with systems that require a Class 2 isolated power unit?

The datasheet lists UL1310, TUV EN61347-1 / EN61347-2-13 and CAN/CSA C22.2 No. 223-M91 safety approvals, with 3.75KVAC input-to-output withstand voltage. It does not state a Class 2 or LPS rating, so confirm those requirements against the full sheet before selection.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8423873708331, "variants" :[{ "context":"default", "variant_id": 45636313579819, "sku":"PLC-30-15", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well PLC-30-15 Power Supply 30W 15V - PFC 2A
Mean Well

Mean Well PLC-30-15 Power Supply 30W 15V - PFC 2A

PLC-30-15 is the 15V output model of this series: rated current 2A, rated power 30W, typical efficiency 83.5%.

Features

  • Universal AC input / Full range
  • Adjustable output voltage and current level
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Fully isolated plastic case with terminal block style of I/O
  • Built-in active PFC function, comply with BS EN/EN61000-3-2 class C (Pin≧25W)
  • Class Ⅱ power unit, no FG
  • Class 2 power unit
  • 100% full load burn-in test
  • High reliability

Typical applications

  • Suitable for LED lighting and moving sign applications (Note.2)
  • Compliance to worldwide safety regulations for lighting
  • 2 years warranty
View product