Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
MDD02L-15N is the ±15V output model of this series: rated power 2W, typical efficiency 86%.
MDS02-N and MDD02-N series are 2W isolated and unregulated module type medical grade DC-DC converter with SIP7 package. It features international standard pins, a high efficiency up to 86%, wide working temperature range -40~+95℃, 6KVDC I/P-O/P high isolation voltage, short circuit protection, etc. The models account for different input voltage 5V/12V/24V±10%, and various output voltage, 3.3V/5V/12V/15V for single output and ±5V /±12V/±15V for dual outputs, which are suitable for medical systems, ultra low leakage current or industrial control, telecommunication field, distributed power architecture, and so on.
Features
- SIP7 package with international standard pinout
- Operating temperature range -40 ~ +95℃
- Comply with IEC/UL62368-1 and LVD IEC60601-1
- Medical safety approved (1xMOPP/2xMOOP) according to IEC60601-1
- Low patient leakage current <2μA
- Protections: Short circuit (Continuous)
- 6KVDC hight I/O isolation (Reinforced insulation)
- Low cost
- 3 years warranty
Specifications
MODEL SELECTION TABLE
- INPUT VOLTAGE (RANGE)
- Normal 5V (4.5 ~ 5.5V)
- INPUT CURRENT NO LOAD
- 46mA
- INPUT CURRENT FULL LOAD
- 455mA
- OUTPUT VOLTAGE
- ±15V
- OUTPUT CURRENT
- ±7 ~ 67mA
- EFFICIENCY (TYP.)
- 86%
- CAPACITOR LOAD (MAX.)* For each output
- *150μF
INPUT
- VOLTAGE RANGE
- 4.5 ~ 5.5Vdc
- FILTER
- Internal capacitor
- PROTECTION
- Fuse recommended. 500mA Slow-Blow Type for all models
OUTPUT
- VOLTAGE ACCURACY
- ±5.0%
- RATED POWER
- 2W
- RIPPLE & NOISENote.2
- 100mVp-p
- LINE REGULATIONNote.3
- 1.2% for 1% input variation
- LOAD REGULATIONNote.4
- ±15% for 3.3Vo, 5Vo ; ±10% for others
- SWITCHING FREQUENCY (Typ.)
- 20KHz
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +95℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +105℃
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +125℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- 0.02% / ℃ (0 ~ 90℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC ( Note.6)
- SAFETY STANDARDS
- IEC62368-1 / UL62368-1, LVD IEC60601-1, EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:6KVDC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- ISOLATION LEVEL
- Primary-secondary: 1xMOPP / 2xMOOP when system input voltage is with 250VAC
- ISOLATION CAPACITANCE (Typ.)
- 25pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032, BS EN/EN55011 Class A/B with external components Radiated BS EN/EN55032, BS EN/EN55011 Class A/B with external components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 2, ±4KV contact, Level 3, ±8KV air Radiated Susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT/Bursts BS EN/EN61000-4-4 Level 1, 0.5KV / 5KHz Surge BS EN/EN61000-4-5 Level 1, 0.5KV Line to Ground Conducted BS EN/EN61000-4-6 Level 2, 3V(e.m.f.) Magnetic Field BS EN/EN61000-4-8 Level 1, 1A/m
OTHERS
- MTBF
- 12900Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 19.7*7.1*11.5mm (0.775*0.279*0.452 inch)
- CASE MATERIAL
- Non-Conductive black plastic (UL 94V-0 rated)
- PACKING
- 2.8g ; 24pcs/per tube, 2160pcs/90 tube/per carton
Test conditions and notes6
- 1.All parameters are specified at normal input(L:5Vdc, M:12Vdc, N:24Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.Patient leakage current(2μA max.) and reinforced isolation is based on a 250VAC, 50/60Hz system input voltage.
- 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Medical devices
- Medical oxygen monitor
- CT scanning
- Medical carts
- Oral care equipment
- Telecom / datacom system
- Wireless network
- Industrial control facility
Downloads
::specification::
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other MDD02 Models
20 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.