💡 New range: Boke DALI-2 LED drivers | 10–240 W | 5-year warranty Explore the range

Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well MDS01L-12N SIP Package DC-DC Converter- 1W - 12V Out 83mA

Input 4.5~5.5VSIP7 package with international standard pinoutmedical gradelow cost
SKU MDS01L-12N
Log in to see price Trade pricing & online ordering for account holders
Available to order
|

Overview

MDS01L-12N is the 12V output model of this series: rated power 1W, typical efficiency 82%.

MDS01-N and MDD01-N series are 1W isolated and unregulated module type medical grade DC-DC converter with SIP7 package. It features international standard pins, a high efficiency up to 84%, wide working temperature range -40~+95℃, 6KVDC I/P-O/P hi-ght isolation voltage, short circuit protection, etc. The models account for different input voltage 5V/12V/24V±10%, and various output voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for medical systems, ultra low leakage current or industrial control, telecommunication field, distributed power architecture, and so on.

Features

  • SIP7 package with international standard pinout
  • Operating temperature range -40 ~ +95℃
  • Comply with IEC/UL62368-1 and LVD IEC60601-1
  • Medical safety approved (1xMOPP/2xMOOP) according to IEC60601-1
  • Low patient leakage current <2μA
  • Protections: Short circuit (Continuous)
  • 6KVDC hi-ght I/O isolation (Reinforced insulation)
  • Low cost
  • 3 years warranty

Specifications

MDS01L-12NSpecifications from the official datasheet (2024-08-12 edition)

INPUT

INPUT VOLTAGE (RANGE)
Normal 5V (4.5 ~ 5.5V)
VOLTAGE RANGE
4.5 ~ 5.5Vdc
INPUT CURRENT (NO LOAD)
26mA
INPUT CURRENT (FULL LOAD)
240mA
FILTER
Internal capacitor
PROTECTION
Fuse recommended. 500mA Slow-Blow Type for all models

OUTPUT

OUTPUT VOLTAGE
12V
OUTPUT CURRENT
9 ~ 84mA
EFFICIENCY(Typ.)
82%
CAPACITOR LOAD(Max.)
220μF
VOLTAGE ACCURACY
±5.0%
RATED POWER
1W
RIPPLE & NOISENote.2
100mVp-p
LINE REGULATIONNote.3
1.2% for 1% input variation
LOAD REGULATIONNote.4
±15% for 3.3Vo, 5Vo ; ±10% for others
SWITCHING FREQUENCY(Typ.)
30KHz

PROTECTION

SHORT CIRCUIT
Protection type : Continuous, automatic recovery

ENVIRONMENT

COOLING
Free-air convection
WORKING TEMP.
-40 ~ +95℃ (Refer to "Derating Curve")
CASE TEMPERATURE
+105℃
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-55 ~ +125℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
0.02% / ℃ (0 ~ 90℃)
SOLDERING TEMPERATURE
1.5mm from case of 1 ~ 3sec./260℃ max.
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
IEC62368-1 / UL62368-1, LVD IEC60601-1, EAC TP TC 020/2011 approved
WITHSTAND VOLTAGE
I/P-O/P:6KVDC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
ISOLATION LEVEL
Primary-secondary: 1xMOPP / 2xMOOP when system input voltage is with 250VAC
ISOLATION CAPACITANCE(Typ.)
10pF
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032, BS EN/EN55011Class A/B with external components
RadiatedBS EN/EN55032, BS EN/EN55011Class A/B with external components
EMC IMMUNITY
ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 2, ±4KV contact, Level 3, ±8KV air
Radiated SusceptibilityBS EN/EN61000-4-3Level 2, 3V/m
EFT/BurstsBS EN/EN61000-4-4Level 1, 0.5KV / 5KHz
SurgeBS EN/EN61000-4-5Level 1, 0.5KV Line to Ground
ConductedBS EN/EN61000-4-6Level 2, 3V(e.m.f.)
Magnetic FieldBS EN/EN61000-4-8Level 1, 1A/m

OTHERS

MTBF
15000Khrs MIL-HDBK-217F(25℃)
DIMENSION (L*W*H)
19.7*7.1*11.5mm (0.775*0.279*0.452 inch)
CASE MATERIAL
Non-Conductive black plastic (UL 94V-0 rated)
PACKING
2.8g ; 24pcs/per tube, 2160pcs/90 tube/per carton
Test conditions and notes6
  1. 1.All parameters are specified at normal input(L:5Vdc, M:12Vdc, N:24Vdc), rated load, 25℃ 70% RH ambient.
  2. 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
  3. 3.Line regulation is measured from low line to high line at rated load.
  4. 4.Load regulation is measured from 10% to 100% rated load.
  5. 5.Patient leakage current(2μA max.) and reinforced isolation is based on a 250VAC, 50/60Hz system input voltage.
  6. 6.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)

Technical drawings

MDS01L-12N Mechanical Specification
Mechanical Specification
MDS01L-12N EMC Suggestion
EMC Suggestion
MDS01L-12N Packing
Packing

Typical applications

  • Medical devices
  • Medical oxygen monitor
  • CT scanning
  • Medical carts
  • Oral care equipment
  • Telecom / datacom system
  • Wireless network
  • Industrial control facility

Downloads

FAQ

What is the Mean Well MDS01L-12N designed for?

The Mean Well MDS01L-12N is a 1W SIP-package DC-DC converter for applications that need regulated 12V DC output in a compact module format. It is suited to embedded industrial, medical, and control-system designs where reinforced isolation and small size are important.

What are the key electrical specifications of the MDS01L-12N?

This model provides 12V DC output with a 1W power rating and a rated output current of 26 mA. It belongs to the MDS01L series, which uses a SIP7 package and is built for isolated DC-DC conversion.

Is the MDS01L-12N suitable for medical or safety-sensitive equipment?

Yes, this converter is medical safety approved to IEC60601-1 with 1xMOPP/2xMOOP and is also listed as complying with IEC/UL62368-1, except for 15Vo and ±15Vo variants. It also features low patient leakage current below 2 μA and 6KVDC I/O isolation with reinforced insulation.

How does the MDS01L-12N perform in harsh temperature environments?

The MDS01L-12N is rated for operation from -40°C to +95°C, making it suitable for demanding temperature conditions. That wide range helps support use in industrial and enclosed electronic applications where ambient temperatures can vary significantly.

What protection features does the MDS01L-12N include?

This model includes continuous short-circuit protection for long-term fault conditions. The series also provides overload protection that shuts down the output when rated power reaches 102% or more, then recovers automatically.

Why would a buyer choose the MDS01L-12N over a non-isolated compact converter?

A key differentiator for the MDS01L-12N is its 6KVDC input-to-output isolation with reinforced insulation in a small SIP7 package. For buyers comparing compact power modules, that combination of medical approvals, low leakage current, and standardized package format can make it a stronger fit for higher-safety designs.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":9596809904427, "variants" :[{ "context":"default", "variant_id": 49368168825131, "sku":"MDS01L-12N", "inventory_qty" : 0, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well MDS01L-12N SIP Package DC-DC Converter- 1W - 12V Out 83mA
Mean Well

Mean Well MDS01L-12N SIP Package DC-DC Converter- 1W - 12V Out 83mA

MDS01L-12N is the 12V output model of this series: rated power 1W, typical efficiency 82%.

MDS01-N and MDD01-N series are 1W isolated and unregulated module type medical grade DC-DC converter with SIP7 package. It features international standard pins, a high efficiency up to 84%, wide working temperature range -40~+95℃, 6KVDC I/P-O/P hi-ght isolation voltage, short circuit protection, etc. The models account for different input voltage 5V/12V/24V±10%, and various output voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for medical systems, ultra low leakage current or industrial control, telecommunication field, distributed power architecture, and so on.

Features

  • SIP7 package with international standard pinout
  • Operating temperature range -40 ~ +95℃
  • Comply with IEC/UL62368-1 and LVD IEC60601-1
  • Medical safety approved (1xMOPP/2xMOOP) according to IEC60601-1
  • Low patient leakage current <2μA
  • Protections: Short circuit (Continuous)
  • 6KVDC hi-ght I/O isolation (Reinforced insulation)
  • Low cost
  • 3 years warranty

Typical applications

  • Medical devices
  • Medical oxygen monitor
  • CT scanning
  • Medical carts
  • Oral care equipment
  • Telecom / datacom system
  • Wireless network
  • Industrial control facility
View product