Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SLW05C-12 is the 12V output model of this series: rated power 5W, typical efficiency 83%.
Features
- 2:1 wide input range
- 4:1 wide input range(option)
- 1500VDC I/O isolation
- 3000VDC I/O isolation(option)
- Built-in EMI filter
- Protections: Short circuit / Overload
- Cooling by free air convection
- Six-sided shield metal case
- 100% burn-in test
- Low cost / High reliability
- Approvals: FCC / EAC / CE / UKCA
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- CURRENT RANGE
- 41.7 ~ 417mA
- RATED POWER
- 5W
- VOLTAGE ACCURACY
- ±2.0%
- RIPPLE & NOISE (max.)Note.2
- 60mVp-p
- LINE REGULATIONNote.3
- ±0.2%
- LOAD REGULATIONNote.4
- ±0.5%
- SWITCHING FREQUENCY
- 50KHz min.
INPUT
- VOLTAGE RANGE
- 36 ~ 72VDC
- EFFICIENCY (Typ.)
- 83%
- DC CURRENT Full load
- 135mA
- DC CURRENT No load
- 10mA
- FILTER
- Pi network
- PROTECTION
- Fuse recommended
PROTECTION (Note. 5)
- OVER CURRENT
- 160 ~ 250% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +71℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -25 ~ +105℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 Class B, FCC part 15 Class B , EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A , EAC TP TC 020
OTHERS
- MTBF
- 800khrs min. MIL-HDBK-217F(25℃)
- DIMENSION
- 50.8*25.4*11.27mm or 2"*1"*0.44" inch (L*W*H)
- PACKING
- 31.2g ; 10pcs/per tube, 400pcs/40 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
Technical drawings
Downloads
FAQ
Can I use the SLW05C-12 to supply 12V control electronics from a 36-72VDC source?
Yes, this converter provides a constant 12V output with a specified 36-72VDC input range. It is rated at 5W and 417mA output current, so it fits low-power 12V control, embedded, or monitoring circuits matched to those published figures.
Is the SLW05C-12 suitable for 12V embedded modules inside industrial equipment?
It is appropriate where the embedded module requires constant 12V and the source available in the equipment is 36-72VDC. The converter is compact at 50.8 × 25.4 × 11.27 mm and weighs 31.2g, which supports integration into space-constrained assemblies.
Can this model be used for 12V automation interface boards in higher-voltage systems?
It can be used for 12V interface boards or similar electronics when the system source falls within 36-72VDC and the load stays within 5W. The key fit is constant-voltage 12V output rather than variable or higher-power output requirements.
How does the SLW05C-12 compare to the rest of the SLW05C family?
The SLW05C family consists of SLW05C-05 at 5W, 5V, 1000mA; SLW05C-09 at 5W, 9V, 556mA; SLW05C-12 at 5W, 12V, 417mA; and SLW05C-15 at 5W, 15V, 333mA. All models share 36-72VDC input, constant-voltage operation, 50.8 × 25.4 × 11.27 mm dimensions, and a -25°C to +71°C operating temperature range.
Can the SLW05C-12 be used where temperatures change a lot or where the unit may be outdoors?
The specified operating range is -25°C to +71°C, so temperature conditions should stay inside that window. Because no IP rating is provided in the specs, outdoor use depends on the enclosure and overall system protection rather than on this converter alone.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other SLW05 Models
11 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.