Mean Well HRP-600-48 Power Supply 624W 48V 13A

built-in active PFChigh efficiency up to 90%no load power consumption <0.5W~0.75W
SKU HRP-600-48
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 7 in this family

HRP-600-48
In stock
|

Overview

HRP-600-48 is the 48V output model of this series: rated current 13A, rated power 624W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in constant current limiting circuit
  • Built-in cooling fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote sense function
  • All using 105℃ long life electrolytic capacitors
  • 5 years warranty

Specifications

HRP-600-48Specifications from the official datasheet (2026-04-03 edition)

OUTPUT

DC VOLTAGE
48V
RATED CURRENT
13A
CURRENT RANGE
0 ~ 13A
RATED POWER
624W
RIPPLE & NOISE (max.)Note.2
240mVp-p
VOLTAGE ADJ. RANGE
40.8 ~ 55.2V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.2%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
1800ms, 50ms/230VAC 3600ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.5
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
7.6A/115VAC 3.6A/230VAC
INRUSH CURRENT (Typ.)
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

DC OK SIGNAL
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
FAN CONTROL (Typ.)
Load 35±15% or RTH2≧50℃ Fan on

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 4)

SAFETY STANDARDS
UL62368-1, TUV BS EN/ EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/ EN55032 (CISPR32) Class B, BS EN/ EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55024, BS EN/ EN61000-6-2, heavy industry level, EAC TP TC 020

OTHERS

MTBF
1333.6K hrs min. Telcordia SR-332 (Bellcore) ; 140.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
218*105*63.5mm (L*W*H)
PACKING
1.5Kg;8pcs/13Kg/1.34CUFT
Test conditions and notes6
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRP-600-48 Mechanical Specification
Mechanical Specification
HRP-600-48 Block Diagram
Block Diagram
HRP-600-48 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the HRP-600-48 for 48V telecom or network power systems?

Yes, this model provides constant voltage 48V output at 13A, with 624W total power. That makes it a practical fit for equipment designed around a 48V DC bus rather than lower-voltage industrial rails.

Is the HRP-600-48 suitable for industrial Ethernet or communications equipment that runs on 48V DC?

It is suitable when the equipment requires a regulated 48V input and the total load stays within 13A and 624W. The wide 85-264VAC input also helps in facilities using different AC mains ranges.

Can the HRP-600-48 be used for a centralized 48V power bus in control cabinets?

It can fit centralized 48V distribution where multiple loads share one supply, provided the combined demand does not exceed 13A or 624W. Its constant voltage design is intended for systems built around a fixed 48V rail.

How does the HRP-600-48 compare with the other HRP-600 voltage options?

The HRP-600 range listed here includes 3.3V 120A 396W, 5V 120A 600W, 7.5V 80A 600W, 12V 53A 636W, 15V 43A 645W, 24V 27A 648W, 36V 17.5A 630W, and 48V 13A 624W. The HRP-600-48 is the highest-voltage standard-output model in that group and shares the same 218.0 × 105.0 × 63.5 mm housing and 1.5 kg weight.

Is the HRP-600-48 rated for outdoor use or washdown areas?

The operating temperature spec is -40°C to +70°C, so the unit covers a broad temperature range. However, there is no IP rating listed in the provided specs, so it should be used indoors or inside a suitable protective enclosure rather than in exposed outdoor or washdown locations.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8343885709611, "variants" :[{ "context":"default", "variant_id": 45320989376811, "sku":"HRP-600-48", "inventory_qty" : 6, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRP-600-48  Power Supply 624W 48V 13A
Mean Well

Mean Well HRP-600-48 Power Supply 624W 48V 13A

HRP-600-48 is the 48V output model of this series: rated current 13A, rated power 624W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in constant current limiting circuit
  • Built-in cooling fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote sense function
  • All using 105℃ long life electrolytic capacitors
  • 5 years warranty

Model

  • 75W 48V
  • 100W 48V
  • 150W 48V
  • 200W 48V
  • 300W 48V
  • 450W 48V
  • 600W 48V
View product