Mean Well HRP-600-36 Power Supply 630W 36V 17.5A

built-in active PFChigh efficiency up to 90%no load power consumption <0.5W~0.75W
SKU HRP-600-36
Log in to see price Trade pricing & online ordering for account holders
Model

Select model — 7 in this family

HRP-600-36
In stock
|

Overview

HRP-600-36 is the 36V output model of this series: rated current 17.5A, rated power 630W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in constant current limiting circuit
  • Built-in cooling fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote sense function
  • All using 105℃ long life electrolytic capacitors
  • 5 years warranty

Specifications

HRP-600-36Specifications from the official datasheet (2026-04-03 edition)

OUTPUT

DC VOLTAGE
36V
RATED CURRENT
17.5A
CURRENT RANGE
0 ~ 17.5A
RATED POWER
630W
RIPPLE & NOISE (max.)Note.2
200mVp-p
VOLTAGE ADJ. RANGE
28.8 ~ 39.6V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.2%
LOAD REGULATION
±0.5%
SETUP, RISE TIME
1800ms, 50ms/230VAC 3600ms, 50ms/115VAC at full load
HOLD UP TIME (Typ.)
16ms/230VAC 16ms/115VAC at full load

INPUT

VOLTAGE RANGENote.5
85 ~ 264VAC 120 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.93/230VAC PF>0.99/115VAC at full load
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
7.6A/115VAC 3.6A/230VAC
INRUSH CURRENT (Typ.)
35A/115VAC 70A/230VAC
LEAKAGE CURRENT
<1.2mA / 240VAC

PROTECTION

OVERLOAD
105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE
41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

FUNCTION

DC OK SIGNAL
PSU turn on : 3.3 ~ 5.6V ; PSU turn off : 0 ~ 1V
FAN CONTROL (Typ.)
Load 35±15% or RTH2≧50℃ Fan on

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC (Note 4)

SAFETY STANDARDS
UL62368-1, TUV BS EN/ EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/ EN55032 (CISPR32) Class B, BS EN/ EN61000-3-2,-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55024, BS EN/ EN61000-6-2, heavy industry level, EAC TP TC 020

OTHERS

MTBF
1333.6K hrs min. Telcordia SR-332 (Bellcore) ; 140.7K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
218*105*63.5mm (L*W*H)
PACKING
1.5Kg;8pcs/13Kg/1.34CUFT
Test conditions and notes6
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  5. 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
  6. 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

HRP-600-36 Mechanical Specification
Mechanical Specification
HRP-600-36 Block Diagram
Block Diagram
HRP-600-36 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the HRP-600-36 for a 36V industrial control or motion system?

Yes, it is a constant voltage 36V supply rated for 17.5A and 630W, which suits higher-load 36V equipment. It is a better match for systems specifically designed around a fixed 36V DC input than lower-voltage HRP-600 versions.

Is the HRP-600-36 suitable for centralized 36V DC distribution in automation equipment?

It can be used where multiple 36V loads share one supply, as long as the combined demand remains within 17.5A and 630W. That makes it relevant for larger automation or industrial electronics assemblies using a 36V bus.

Can this model power embedded or industrial devices that expect a regulated 36V input?

It is built for constant voltage output at 36V, so it fits equipment that requires a fixed 36V source. The available 630W and 17.5A give it capacity for larger 36V embedded or industrial loads.

What is the difference between the HRP-600-36 and the other HRP-600 models?

The listed HRP-600 outputs are 3.3V 120A 396W, 5V 120A 600W, 7.5V 80A 600W, 12V 53A 636W, 15V 43A 645W, 24V 27A 648W, 36V 17.5A 630W, and 48V 13A 624W. The HRP-600-36 is the 36V option in that set, while keeping the same 218.0 × 105.0 × 63.5 mm dimensions and 1.5 kg weight.

Can the HRP-600-36 handle demanding temperature conditions?

Its operating temperature range is -40°C to +70°C, so it is specified for a wide range of indoor industrial conditions. Since no IP rating is listed, it should be treated as a protected-location power supply rather than an exposed outdoor unit.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Union Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8343885480235, "variants" :[{ "context":"default", "variant_id": 45320988492075, "sku":"HRP-600-36", "inventory_qty" : 6, "customer" :false, "custom_html" :"\u003ca class=\"text-current logged-out-price logged-out\" href=\"https:\/\/wellforces.co.nz\/customer_authentication\/redirect?locale=en\u0026region_country=NZ\"\u003e\n \u003cspan \u003ePlease \u003c\/span\u003e \u003cspan class=\"login-text\"\u003eLogin\u003c\/span\u003e \u003cspan\u003e for Pricing\u003c\/span\u003e\n \u003c\/a\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HRP-600-36  Power Supply 630W 36V 17.5A
Mean Well

Mean Well HRP-600-36 Power Supply 630W 36V 17.5A

HRP-600-36 is the 36V output model of this series: rated current 17.5A, rated power 630W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • Built-in active PFC function, PF>0.93
  • High efficiency up to 89%
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • Built-in constant current limiting circuit
  • Built-in cooling fan ON-OFF control
  • Built-in DC OK signal
  • Built-in remote sense function
  • All using 105℃ long life electrolytic capacitors
  • 5 years warranty

Model

  • 75W 36V
  • 100W 36V
  • 150W 36V
  • 200W 36V
  • 300W 36V
  • 450W 36V
  • 600W 36V
View product