Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
MPS-65-48 is the 48V output model of this series: rated current 1.35A, rated power 64.8W, typical efficiency 80%.
Features
- Universal AC input / Full range
- Low leakage current <250μA
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Medical safety approved (2 x MOPP between primary to secondary)
- 100% full load burn-in test
- Fixed switching frequency at 45KHz
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 1.35A
- CURRENT RANGE
- 0 ~ 1.5A
- RATED POWER
- 64.8W
- OUTPUT POWER (max.)
- 72W(+3.3V:50W;+5V:69W)with 18CFM min. Forced air convection
- RIPPLE & NOISE (max.)Note.2
- 100mVp-p
- VOLTAGE ADJ. RANGE
- 43.2 ~ 52.8V
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIME
- 800ms, 30ms/230VAC 800ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY(Typ.)
- 80%
- AC CURRENT (Typ.)
- 1.6A/115VAC 0.9A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 17A/115VAC 40A/230VAC
- LEAKAGE CURRENTNote.7
- Earth leakage current < 250μA/264VAC , Touch current < 60μA/264VAC
PROTECTION
- OVERLOAD
- 73 ~ 105W (3.3V:51 ~ 75W)(5V:70 ~ 105W) rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 55.2 ~ 64.8V Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -10 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.04%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- ANSI/AAMI ES60601-1, TUV EN60601-1, IEC60601-1 approved
- ISOLATION LEVEL
- Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP
- WITHSTAND VOLTAGE
- I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to EN55011 (CISPR11) Class B, EN61000-3-2,-3
- EMC IMMUNITY
- Compliance to EN61000-4-2,3,4,5,6,8,11, EN60601-1-2, medical level, criteria A
OTHERS
- MTBF
- 359.7Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 127*76*42mm (L*W*H)
- PACKING
- 0.23Kg; 54pcs/14.6Kg/1.28CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
- 5. Mounting holes M1 and M2 should be grounded for EMI purposes.
- 6. Heat Sink HS1,HS2 can not be shorted.
- 7. Touch current was measured from primary input to DC output.
Technical drawings
Downloads
Catalogues1
FAQ
Can I use the MPS-65-48 for a 48V PLC, sensor, or industrial control load?
Yes, this model is a constant-voltage 48V supply rated for 1.35A and 64.8W. It fits industrial or automation equipment that requires a regulated 48V DC input and stays within that current and power limit.
Is the MPS-65-48 suitable for 48V embedded or communications hardware?
It can be used for embedded or communications equipment that needs a constant 48V output and draws no more than 1.35A. The wide 90-264VAC input also supports installations where the AC source may vary across regions.
Can this power supply run a low-power 48V automation node instead of a higher-wattage 48V unit?
Yes, if the load is within 64.8W and 1.35A at 48V, this model is sized for lower-power 48V applications. Larger 48V loads need a higher-rated supply than this model.
Can I use the MPS-65-48 for indoor industrial equipment in normal plant conditions?
The published operating temperature range is -10°C to +60°C, so it is specified for that temperature window. No IP rating is listed in the provided specs, so outdoor or washdown use is not defined by this product data.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other MPS-65 Models
8 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well MPS-65-7.5Power Supply 65W 7.5V 8A | 60W | 7.5V | 8A | View |
| Mean Well MPS-65-5 Power Supply 65W 5V 12A | 60W | 5V | 12A | View |
| Mean Well MPS-65-3.3 Power Supply 65W 3.3V 12A | 39.6W | 3.3V | 12A | View |
| Mean Well MPS-65-27 Power Supply 65W 27V 2.4A | 64.8W | 27V | 2.4A | View |
| Mean Well MPS-65-24 Power Supply 65W 24V 2.7A | 64.8W | 24V | 2.7A | View |
| Mean Well MPS-65-15 Power Supply 65W 15V 4.2A | 63W | 15V | 4.2A | View |
| Mean Well MPS-65-13.5 Power Supply 65W 13.5V 4.7A | 63.45W | 13.5V | 4.7A | View |
| Mean Well MPS-65-12 Power Supply 65W 12V 5.2A | 62.4W | 12V | 5.2A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.