Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NSD10-12D12 is the 12V -12V output model of this series: rated current 0.42A 0.42A, rated power 10.08W, typical efficiency 77%.
Features
- Wide 4:1 DC input range
- Protections: Short circuit / Overload / Over voltage
- 1000VDC I/O isolation
- Built-in EMI filter
- Cooling by free air convection
- Built-in remote ON-OFF control
- 100% full load burn-in test
- Lost cost
- High reliability
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V -12V
- RATED CURRENT
- 0.42A 0.42A
- CURRENT RANGE
- 0.02 ~ 0.42A 0.02 ~ 0.42A
- RATED POWER
- 10.08W
- CAPACITIVE LOAD (max.)
- ±1000uF
- RIPPLE & NOISE (max.)Note.2
- 75mVp-p(10% ~ 100% load)
- VOLTAGE TOLERANCENote.3
- ±2.5%
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±2.0%
- SETUP TIME
- 100ms/RATED DC INPUT at full Load
INPUT
- RATED DC INPUT
- 12VDC
- VOLTAGE RANGE
- 9.8 ~ 36VDC
- EFFICIENCY (Typ.)
- 77%
- DC CURRENT
- 1.4A/12VDC
- SHUTDOWN IDLE CURRENT
- 20mA/12VDC
PROTECTION
- OVERLOAD
- Above 105% rated output power Protection type : Over power limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE(CLAMP)
- 13.8 ~ 18V -13.8 ~ -18V
- SHORT CIRCUITNote.4
- Recovers automatically after fault condition is removed
FUNCTION
- ON/OFF CONTROL
- Logic "1" OPEN: ON logic "0" GND: OFF
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃
- WORKING HUMIDITY
- 0% ~ 95% RH max.
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 0 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~60℃)
SAFETY & EMC (Note 5)
- SAFETY STANDARDS
- UL62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
- ISOLATION VOLTAGE
- I/P-O/P:1KVDC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,6,8; BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 12288.5K hrs min. Telcordia SR-332 (Bellcore) ; 1878.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*25.4*10mm (2"*1"*0.394") (L*W*H)
- PACKING
- 0.02Kg; 300pcs/7Kg/0.94CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 12, 48VDC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Short circuit not more than 60 seconds.
- 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 6. To insure proper operation, a 220uF/100V electrolytic capacitor with Esr <1Ω must be added to the input line.
- 7. EMC filter suggestion:
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the NSD10-12D12 for bipolar analog signal conditioning in industrial control equipment?
Yes, this model is suited to control and instrumentation designs that need a constant-voltage ±12V output from a 9.8~36VDC input range. Its 10.08W rating fits lower-power analog sections rather than larger ±12V loads.
Is the NSD10-12D12 a good fit for embedded test and measurement circuits that need dual rails?
It can fit embedded and bench-level electronics that require ±12V rails and stay within the converter's 10.08W capacity. The wide 9.8~36VDC input range also makes it easier to use across variable low-voltage source conditions.
Can I use this DC-DC converter in an industrial interface module with ±12V requirements?
Yes, if the interface electronics specifically require constant-voltage ±12V output and the total load remains within 10.08W. This model is more appropriate for compact control, monitoring, and analog interface sections than for higher-power ±12V assemblies.
How does the NSD10-12D12 compare with the other NSD10 12-input series models?
Within the 9.8~36VDC input NSD10-D models, NSD10-12D5 is 10W, ±5V, 1A per output; NSD10-12D12 is 10.08W, ±12V, 0.42A; and NSD10-12D15 is 9.9W, ±15V, 0.33A. The 22~72VDC NSD10-48D5, NSD10-48D12 and NSD10-48D15 offer the same outputs from a 48VDC-class input. The main difference is the output voltage and power/current rating; this unit provides ±12V at 0.42A per output.
Is the NSD10-12D12 suitable for outdoor or harsh-temperature use?
The specified operating range is -25°C to +70°C, so the temperature range covers many industrial indoor environments. The product details provided here do not list an IP rating, so outdoor exposure suitability is not established by this spec set.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NSD10 Models
15 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.