Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NSD10-48S9 is the 9V output model of this series: rated current 1.1A, rated power 9.9W, typical efficiency 78%.
Features
- Wide 4:1 DC input range
- Protections: Short circuit / Overload / Over voltage
- 1000VDC I/O isolation
- Built-in EMI filter
- Cooling by free air convection
- Built-in remote ON-OFF control
- 100% full load burn-in test
- Low cost
- High reliability
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 9V
- RATED CURRENT
- 1.1A
- CURRENT RANGE
- 0.05 ~ 1.1A
- RATED POWER
- 9.9W
- CAPACITIVE LOAD (max.)
- 3300uF
- RIPPLE & NOISE (max.)Note.2
- 75mVp-p
- VOLTAGE TOLERANCENote.3
- ±2.0% max.
- LINE REGULATION
- ±1.0%
- LOAD REGULATION
- ±1.0%
- SETUP TIME
- 100ms/RATED DC INPUT at full Load
INPUT
- RATED DC INPUT
- 48VDC
- VOLTAGE RANGE
- 22 ~ 72VDC
- EFFICIENCY (Typ.)
- 78%
- DC CURRENT
- 0.4A/48VDC
- SHUTDOWN IDLE CURRENT
- 20mA/12VDC
PROTECTION
- OVERLOAD
- Above 105% rated output power Protection type : Over power limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE(CLAMP)
- 10.4 ~ 13.5V
- SHORT CIRCUITNote.4
- Recovers automatically after fault condition is removed
FUNCTION
- ON/OFF CONTROL
- Logic "1" OPEN: ON logic "0" GND: OFF
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃
- WORKING HUMIDITY
- 0% ~ 95% RH max.
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 0 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0~60℃)
SAFETY & EMC (Note 5)
- SAFETY STANDARDS
- UL62368-1, EAC TP TC 004 approved, Design refer to BS EN/EN62368-1
- ISOLATION VOLTAGE
- I/P-O/P:1KVDC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,6,8; BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 12058.3K hrs min. Telcordia SR-332 (Bellcore) ; 2138.0K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 50.8*25.4*10mm (2"*1"*0.394") (L*W*H)
- PACKING
- 0.02Kg; 300pcs/7Kg/0.94CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 12, 48VDC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Short circuit not more than 60 seconds.
- 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 230mm*230mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 6. To insure proper operation, a 220uF/100V electrolytic capacitor with Esr <1Ω must be added to the input line.
- 7. EMC filter suggestion:
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the NSD10-48S9 to power a 9V embedded controller from a wide industrial DC bus?
Yes, this converter is suited to low-power embedded electronics that need a regulated 9V output from a 22-72V input range. Its 9.9W rating and 1.1A output current fit small controller, interface, and monitoring circuits rather than higher-draw loads.
Is the NSD10-48S9 a fit for 48V automation panels that need a separate 9V rail?
It can fit automation panels that distribute a 48V-class input within the stated 22-72V range and need a constant-voltage 9V output. With 9.9W available, it is better matched to auxiliary electronics, compact sensors, and low-power control sections than larger actuators.
Can this 9V converter be used for industrial sensing or monitoring modules?
It is appropriate for low-power sensing and monitoring modules that need a stable 9V rail and stay within 1.1A output current. The wide 22-72V input range also makes it practical where DC bus voltage can vary across different industrial or mobile systems.
Is the NSD10-48S9 suitable for outdoor or harsh-environment use?
The working temperature range is -25°C to +70°C, with storage from -40°C to +85°C, so the specs support operation across that span. However, no IP rating is listed, so the provided specs do not confirm protection against water or dust for exposed outdoor installation.
How does the NSD10-48S9 compare with the other NSD10 series options?
On the NSD10-S spec sheet, the 9.8~36VDC input versions are NSD10-12S3 at 8.25W, 3.3V, 2.5A; NSD10-12S5 at 10W, 5V, 2A; NSD10-12S9 at 9.9W, 9V, 1.1A; NSD10-12S12 at 9.96W, 12V, 0.83A; and NSD10-12S15 at 10.05W, 15V, 0.67A. The other 22~72VDC input versions are NSD10-48S3 at 8.25W, 3.3V, 2.5A; NSD10-48S5 at 10W, 5V, 2A; NSD10-48S12 at 9.96W, 12V, 0.83A; and NSD10-48S15 at 10.05W, 15V, 0.67A. The NSD10-48S9 itself is the 9.9W, 9V, 1.1A single-output option in that group.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NSD10 Models
15 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.